对军事训练期间四个解剖位置的可穿戴技术的可接受性和舒适性进行为期五天的评估。

IF 1.4 4区 医学 Q2 MEDICINE, GENERAL & INTERNAL
Natalie Taylor, A Carroll, R M Gifford
{"title":"对军事训练期间四个解剖位置的可穿戴技术的可接受性和舒适性进行为期五天的评估。","authors":"Natalie Taylor, A Carroll, R M Gifford","doi":"10.1136/military-2023-002524","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Wearable sensor technologies enable Defence to optimise human performance, remotely identify physiological abnormalities and enhance medical support. Maximising the acceptability of devices will ensure they are worn alongside other equipment. This study assessed the acceptability and comfort of four devices at different anatomical locations during military training.</p><p><strong>Method: </strong>A cross-sectional pilot study during a live firing infantry exercise or adventurous training assessed four anatomical locations concurrently over 5 days: finger, wrist, upper arm and chest. Participants rated comfort, acceptability and preference using a standardised questionnaire after 12 hours and 5 days of wear.</p><p><strong>Results: </strong>Twenty-one regular British Army personnel soldiers participated, aged 24.4 (4.3) years. The upper arm location received the highest rating by participants for comfort, followed in order by wrist, finger and chest (p=0.002, Χ<sup>2</sup>=40.0). The finger was most commonly identified as uncomfortable during specific activities (76%), followed by chest (48%), wrist (23%) and upper arm devices (14%). There was no significant difference in participant confidence in the devices to collect data or allow movement, but there was a trend towards greater confidence in upper arm and wrist locations to stay in position than the others (p=0.059, Χ<sup>2</sup>=28.0). After 5 days of wear, 43% of participants said they preferred the upper arm for comfort, followed by wrist (36%), finger (24%) and chest (10%). 73% and 71% would wear the wrist and upper arm devices on deployed operations, compared with 29% and 24% for chest and finger devices, respectively.</p><p><strong>Conclusion: </strong>The upper arm location offered greater acceptability and comfort than finger, wrist or chest locations. It is essential to consider such findings from occupationally relevant settings when selecting wearable technology. A larger service evaluation in diverse settings is recommended to guide the choice of the most acceptable wearable devices across different equipment, roles and environments.</p>","PeriodicalId":48485,"journal":{"name":"Bmj Military Health","volume":" ","pages":"245-249"},"PeriodicalIF":1.4000,"publicationDate":"2025-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Five-day evaluation of the acceptability and comfort of wearable technology at four anatomical locations during military training.\",\"authors\":\"Natalie Taylor, A Carroll, R M Gifford\",\"doi\":\"10.1136/military-2023-002524\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Wearable sensor technologies enable Defence to optimise human performance, remotely identify physiological abnormalities and enhance medical support. Maximising the acceptability of devices will ensure they are worn alongside other equipment. This study assessed the acceptability and comfort of four devices at different anatomical locations during military training.</p><p><strong>Method: </strong>A cross-sectional pilot study during a live firing infantry exercise or adventurous training assessed four anatomical locations concurrently over 5 days: finger, wrist, upper arm and chest. Participants rated comfort, acceptability and preference using a standardised questionnaire after 12 hours and 5 days of wear.</p><p><strong>Results: </strong>Twenty-one regular British Army personnel soldiers participated, aged 24.4 (4.3) years. The upper arm location received the highest rating by participants for comfort, followed in order by wrist, finger and chest (p=0.002, Χ<sup>2</sup>=40.0). The finger was most commonly identified as uncomfortable during specific activities (76%), followed by chest (48%), wrist (23%) and upper arm devices (14%). There was no significant difference in participant confidence in the devices to collect data or allow movement, but there was a trend towards greater confidence in upper arm and wrist locations to stay in position than the others (p=0.059, Χ<sup>2</sup>=28.0). After 5 days of wear, 43% of participants said they preferred the upper arm for comfort, followed by wrist (36%), finger (24%) and chest (10%). 73% and 71% would wear the wrist and upper arm devices on deployed operations, compared with 29% and 24% for chest and finger devices, respectively.</p><p><strong>Conclusion: </strong>The upper arm location offered greater acceptability and comfort than finger, wrist or chest locations. It is essential to consider such findings from occupationally relevant settings when selecting wearable technology. A larger service evaluation in diverse settings is recommended to guide the choice of the most acceptable wearable devices across different equipment, roles and environments.</p>\",\"PeriodicalId\":48485,\"journal\":{\"name\":\"Bmj Military Health\",\"volume\":\" \",\"pages\":\"245-249\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2025-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bmj Military Health\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1136/military-2023-002524\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bmj Military Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/military-2023-002524","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

导言:可穿戴传感器技术使国防部门能够优化人体性能、远程识别生理异常并加强医疗支持。最大限度地提高设备的可接受性将确保它们与其他设备一起佩戴。本研究评估了军事训练中不同解剖位置的四种设备的可接受性和舒适性:方法: 在步兵实弹演习或冒险训练期间进行的一项横断面试点研究在 5 天内同时评估了四个解剖位置:手指、手腕、上臂和胸部。参与者在佩戴 12 小时和 5 天后使用标准化问卷对舒适度、可接受性和偏好进行评分:结果:21 名英国陆军正规军士兵参加了测试,年龄为 24.4(4.3)岁。佩戴者对上臂位置的舒适度评价最高,其次依次是手腕、手指和胸部(p=0.002,Χ2=40.0)。在特定活动中,手指最常被认为不舒适(76%),其次是胸部(48%)、手腕(23%)和上臂装置(14%)。受试者对设备收集数据或允许移动的信心没有明显差异,但对上臂和手腕位置保持位置的信心有高于其他位置的趋势(p=0.059,Χ2=28.0)。佩戴 5 天后,43% 的参与者表示上臂佩戴更舒适,其次是手腕(36%)、手指(24%)和胸部(10%)。73%和 71% 的受试者会在部署行动中佩戴手腕和上臂装置,而佩戴胸部和手指装置的受试者比例分别为 29% 和 24%:上臂位置比手指、手腕或胸部位置更容易接受,也更舒适。在选择可穿戴技术时,有必要考虑职业相关环境中的此类发现。建议在不同环境中进行更大规模的服务评估,以指导在不同设备、角色和环境中选择最易接受的可穿戴设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Five-day evaluation of the acceptability and comfort of wearable technology at four anatomical locations during military training.

Introduction: Wearable sensor technologies enable Defence to optimise human performance, remotely identify physiological abnormalities and enhance medical support. Maximising the acceptability of devices will ensure they are worn alongside other equipment. This study assessed the acceptability and comfort of four devices at different anatomical locations during military training.

Method: A cross-sectional pilot study during a live firing infantry exercise or adventurous training assessed four anatomical locations concurrently over 5 days: finger, wrist, upper arm and chest. Participants rated comfort, acceptability and preference using a standardised questionnaire after 12 hours and 5 days of wear.

Results: Twenty-one regular British Army personnel soldiers participated, aged 24.4 (4.3) years. The upper arm location received the highest rating by participants for comfort, followed in order by wrist, finger and chest (p=0.002, Χ2=40.0). The finger was most commonly identified as uncomfortable during specific activities (76%), followed by chest (48%), wrist (23%) and upper arm devices (14%). There was no significant difference in participant confidence in the devices to collect data or allow movement, but there was a trend towards greater confidence in upper arm and wrist locations to stay in position than the others (p=0.059, Χ2=28.0). After 5 days of wear, 43% of participants said they preferred the upper arm for comfort, followed by wrist (36%), finger (24%) and chest (10%). 73% and 71% would wear the wrist and upper arm devices on deployed operations, compared with 29% and 24% for chest and finger devices, respectively.

Conclusion: The upper arm location offered greater acceptability and comfort than finger, wrist or chest locations. It is essential to consider such findings from occupationally relevant settings when selecting wearable technology. A larger service evaluation in diverse settings is recommended to guide the choice of the most acceptable wearable devices across different equipment, roles and environments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bmj Military Health
Bmj Military Health MEDICINE, GENERAL & INTERNAL-
CiteScore
3.10
自引率
20.00%
发文量
116
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信