{"title":"用于凝血分析仪的本地、异地和长期可比性的商用人体冷冻血浆。","authors":"Amélie Launois, Sara Zia Chahabi, Floriane Devaux, Isabelle Amouroux, Claire Flaujac","doi":"10.1097/MBC.0000000000001268","DOIUrl":null,"url":null,"abstract":"<p><p>Laboratory compliance implies to correlate instruments for coagulation parameter with a wide range of measure using patient samples or commercialized sets of frozen plasmas. The aim of this study was to evaluate the intra, inter-reproducibility and long-term stability of ExpertCor Routine (ECR) plasma sets (Stago) on different parameters. The study was realized in two laboratories on four different instruments. Inter-site and intra-site correlation of ECR sets for PT, aPTT, Fibrinogen, INR, factor V (FV) UFH and LMWH anti-Xa and intra-reproducibility of DDimer (DDI), factor VIII (FVIII:C) and antithrombin (AT) assays were tested. To evaluate ECR long-term stability, samples were tested until 180 after delivery in one laboratory. Intra-site evaluation correlation coefficients is around 1. All predefined criteria to fulfil good comparability between inter-site instruments are met with Passing slopes between 0.9 and 1.1 and intercepts ranging from -0.62 to 2.83%. Long-term stability evaluation does not show any deviation over 180 days for aPTT, fibrinogen, DDI, UFH, LMWH but a drift for FV with STA-NeoPTimal reagent. On contrary, AT and FVIII:C are not stable. PT in second has an excellent stability unlike PT in percentage. Our study validates the use of ECR sets for correlation between instruments and inter-sites agreement, as for parameters claimed on the products than for factor V and FVIII:C. The evaluation of stability confirming the possible extension of use for 180 days after delivery except for FVIII:C and AT. These plasmas sets are an excellent alternative to local plasma patient use to perform instrument comparison.</p>","PeriodicalId":8992,"journal":{"name":"Blood Coagulation & Fibrinolysis","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Commercial human frozen plasmas for local, cross-site and long-term comparability of coagulation analysers.\",\"authors\":\"Amélie Launois, Sara Zia Chahabi, Floriane Devaux, Isabelle Amouroux, Claire Flaujac\",\"doi\":\"10.1097/MBC.0000000000001268\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Laboratory compliance implies to correlate instruments for coagulation parameter with a wide range of measure using patient samples or commercialized sets of frozen plasmas. The aim of this study was to evaluate the intra, inter-reproducibility and long-term stability of ExpertCor Routine (ECR) plasma sets (Stago) on different parameters. The study was realized in two laboratories on four different instruments. Inter-site and intra-site correlation of ECR sets for PT, aPTT, Fibrinogen, INR, factor V (FV) UFH and LMWH anti-Xa and intra-reproducibility of DDimer (DDI), factor VIII (FVIII:C) and antithrombin (AT) assays were tested. To evaluate ECR long-term stability, samples were tested until 180 after delivery in one laboratory. Intra-site evaluation correlation coefficients is around 1. All predefined criteria to fulfil good comparability between inter-site instruments are met with Passing slopes between 0.9 and 1.1 and intercepts ranging from -0.62 to 2.83%. Long-term stability evaluation does not show any deviation over 180 days for aPTT, fibrinogen, DDI, UFH, LMWH but a drift for FV with STA-NeoPTimal reagent. On contrary, AT and FVIII:C are not stable. PT in second has an excellent stability unlike PT in percentage. Our study validates the use of ECR sets for correlation between instruments and inter-sites agreement, as for parameters claimed on the products than for factor V and FVIII:C. The evaluation of stability confirming the possible extension of use for 180 days after delivery except for FVIII:C and AT. These plasmas sets are an excellent alternative to local plasma patient use to perform instrument comparison.</p>\",\"PeriodicalId\":8992,\"journal\":{\"name\":\"Blood Coagulation & Fibrinolysis\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Blood Coagulation & Fibrinolysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MBC.0000000000001268\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Coagulation & Fibrinolysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBC.0000000000001268","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/25 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
Commercial human frozen plasmas for local, cross-site and long-term comparability of coagulation analysers.
Laboratory compliance implies to correlate instruments for coagulation parameter with a wide range of measure using patient samples or commercialized sets of frozen plasmas. The aim of this study was to evaluate the intra, inter-reproducibility and long-term stability of ExpertCor Routine (ECR) plasma sets (Stago) on different parameters. The study was realized in two laboratories on four different instruments. Inter-site and intra-site correlation of ECR sets for PT, aPTT, Fibrinogen, INR, factor V (FV) UFH and LMWH anti-Xa and intra-reproducibility of DDimer (DDI), factor VIII (FVIII:C) and antithrombin (AT) assays were tested. To evaluate ECR long-term stability, samples were tested until 180 after delivery in one laboratory. Intra-site evaluation correlation coefficients is around 1. All predefined criteria to fulfil good comparability between inter-site instruments are met with Passing slopes between 0.9 and 1.1 and intercepts ranging from -0.62 to 2.83%. Long-term stability evaluation does not show any deviation over 180 days for aPTT, fibrinogen, DDI, UFH, LMWH but a drift for FV with STA-NeoPTimal reagent. On contrary, AT and FVIII:C are not stable. PT in second has an excellent stability unlike PT in percentage. Our study validates the use of ECR sets for correlation between instruments and inter-sites agreement, as for parameters claimed on the products than for factor V and FVIII:C. The evaluation of stability confirming the possible extension of use for 180 days after delivery except for FVIII:C and AT. These plasmas sets are an excellent alternative to local plasma patient use to perform instrument comparison.
期刊介绍:
Blood Coagulation & Fibrinolysis is an international fully refereed journal that features review and original research articles on all clinical, laboratory and experimental aspects of haemostasis and thrombosis. The journal is devoted to publishing significant developments worldwide in the field of blood coagulation, fibrinolysis, thrombosis, platelets and the kininogen-kinin system, as well as dealing with those aspects of blood rheology relevant to haemostasis and the effects of drugs on haemostatic components