Camdon Fary, Jason Cholewa, Anna N Ren, Scott Abshagen, Mike B Anderson, Krishna Tripuraneni
{"title":"多中心、前瞻性队列研究:与使用手动器械的倾向匹配对照相比,机器人辅助全膝关节置换术术后主动活动范围的立即增加。","authors":"Camdon Fary, Jason Cholewa, Anna N Ren, Scott Abshagen, Mike B Anderson, Krishna Tripuraneni","doi":"10.1186/s42836-023-00216-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Range of motion (ROM) following total knee replacement (TKR) has been associated with patient satisfaction and knee function, and is also an early indicator of a successful procedure. Robotic-assisted TKR (raTKR) is considered to reproduce more precise resections, and, as a result, may be associated with improved early patient satisfaction compared to manual TKR (mTKR). The purpose of this study was to evaluate the early postoperative active ROM (aROM) between raTKR and mTKR.</p><p><strong>Methods: </strong>A total of 216 mTKR patients were propensity-matched, in terms of age, gender, comorbidities, and BMI, to 216 raTKR cases. Intraoperative and immediate postoperative adverse events were collected. Knee flexion and extension aROM were measured preoperatively and at one- and three months after operation.</p><p><strong>Results: </strong>Changes in flexion aROM were significantly greater in raTKR vs. mTKR at one- (6.9°, 95% CI: 3.5, 10.4°) and three months (4.9°, 95% CI: 2.1, 7.7°). Flexion aROM was greater at three postoperative months compared to preoperative aROM only in the raTKR group, and raTKR patients had higher odds of achieving ≥ 90° of flexion at one month after operation (OR: 2.15, 95% CI: 1.16, 3.99). There were no significant differences between groups in intraoperative (P > 0.999) or postoperative adverse events.</p><p><strong>Conclusions: </strong>Compared with mTKR, raTKR resulted in less loss of aROM immediately after operation and a faster recovery of aROM within three months after operation.</p><p><strong>Trial registration: </strong>Clinicaltrials.gov (NCT# 03737149).</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10694935/pdf/","citationCount":"0","resultStr":"{\"title\":\"Multicenter, prospective cohort study: immediate postoperative gains in active range of motion following robotic-assisted total knee replacement compared to a propensity-matched control using manual instrumentation.\",\"authors\":\"Camdon Fary, Jason Cholewa, Anna N Ren, Scott Abshagen, Mike B Anderson, Krishna Tripuraneni\",\"doi\":\"10.1186/s42836-023-00216-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Range of motion (ROM) following total knee replacement (TKR) has been associated with patient satisfaction and knee function, and is also an early indicator of a successful procedure. Robotic-assisted TKR (raTKR) is considered to reproduce more precise resections, and, as a result, may be associated with improved early patient satisfaction compared to manual TKR (mTKR). The purpose of this study was to evaluate the early postoperative active ROM (aROM) between raTKR and mTKR.</p><p><strong>Methods: </strong>A total of 216 mTKR patients were propensity-matched, in terms of age, gender, comorbidities, and BMI, to 216 raTKR cases. Intraoperative and immediate postoperative adverse events were collected. Knee flexion and extension aROM were measured preoperatively and at one- and three months after operation.</p><p><strong>Results: </strong>Changes in flexion aROM were significantly greater in raTKR vs. mTKR at one- (6.9°, 95% CI: 3.5, 10.4°) and three months (4.9°, 95% CI: 2.1, 7.7°). Flexion aROM was greater at three postoperative months compared to preoperative aROM only in the raTKR group, and raTKR patients had higher odds of achieving ≥ 90° of flexion at one month after operation (OR: 2.15, 95% CI: 1.16, 3.99). There were no significant differences between groups in intraoperative (P > 0.999) or postoperative adverse events.</p><p><strong>Conclusions: </strong>Compared with mTKR, raTKR resulted in less loss of aROM immediately after operation and a faster recovery of aROM within three months after operation.</p><p><strong>Trial registration: </strong>Clinicaltrials.gov (NCT# 03737149).</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10694935/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s42836-023-00216-0\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-023-00216-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Multicenter, prospective cohort study: immediate postoperative gains in active range of motion following robotic-assisted total knee replacement compared to a propensity-matched control using manual instrumentation.
Background: Range of motion (ROM) following total knee replacement (TKR) has been associated with patient satisfaction and knee function, and is also an early indicator of a successful procedure. Robotic-assisted TKR (raTKR) is considered to reproduce more precise resections, and, as a result, may be associated with improved early patient satisfaction compared to manual TKR (mTKR). The purpose of this study was to evaluate the early postoperative active ROM (aROM) between raTKR and mTKR.
Methods: A total of 216 mTKR patients were propensity-matched, in terms of age, gender, comorbidities, and BMI, to 216 raTKR cases. Intraoperative and immediate postoperative adverse events were collected. Knee flexion and extension aROM were measured preoperatively and at one- and three months after operation.
Results: Changes in flexion aROM were significantly greater in raTKR vs. mTKR at one- (6.9°, 95% CI: 3.5, 10.4°) and three months (4.9°, 95% CI: 2.1, 7.7°). Flexion aROM was greater at three postoperative months compared to preoperative aROM only in the raTKR group, and raTKR patients had higher odds of achieving ≥ 90° of flexion at one month after operation (OR: 2.15, 95% CI: 1.16, 3.99). There were no significant differences between groups in intraoperative (P > 0.999) or postoperative adverse events.
Conclusions: Compared with mTKR, raTKR resulted in less loss of aROM immediately after operation and a faster recovery of aROM within three months after operation.