LC-MS/MS同时测定溴化替托溴铵胶囊制剂中杂质G + H的含量。

IF 1.1 4区 化学 Q4 PHYSICS, ATOMIC, MOLECULAR & CHEMICAL
European Journal of Mass Spectrometry Pub Date : 2024-02-01 Epub Date: 2023-11-30 DOI:10.1177/14690667231217879
Serdar Erkol, Müge Güleli, Cem Çalışkan, Sevgi Kocaoba
{"title":"LC-MS/MS同时测定溴化替托溴铵胶囊制剂中杂质G + H的含量。","authors":"Serdar Erkol, Müge Güleli, Cem Çalışkan, Sevgi Kocaoba","doi":"10.1177/14690667231217879","DOIUrl":null,"url":null,"abstract":"<p><p>Tiotropium Bromide is a long-acting bronchodilator that is used in the treatment of chronic obstructive pulmonary disease (COPD) and asthma bronchodilator or bronchiolitis, which are substances that expand the bronchi and reduce resistance in the respiratory tract and increase airflow to the lungs. For Tiotropium Bromide found in inhaler capsules to treat COPD, determining the relevant impurities G and H, which are not UV active, is crucial. For this purpose, a new and sensitive liquid chromatography triple-quadrupole mass spectrometry (LC-MS/MS) detection with electrospray ionization by using multiple reaction monitoring in the positive mode method was developed and validated. The identity of the compounds was supported by using LC-Q/TOF. All chromatographic studies were performed with a Zorbax Eclipse XDB-C8 (150 mm x 4.6 mm, 5.0 µm) column with a total injection time of 13 min at a flow rate of 0.4 ml/min as a gradient. The limit of detection (LOD) and limit of quantitation (LOQ) in the current study range were determined as 1.0 ppb and 2.5 ppb, respectively. The results of the validation parameters following the ICH Q2(R1) guideline were determined within the acceptance criteria.</p>","PeriodicalId":12007,"journal":{"name":"European Journal of Mass Spectrometry","volume":" ","pages":"76-83"},"PeriodicalIF":1.1000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous quantification of tiotropium bromide impurities G + H in capsule formulation by LC-MS/MS.\",\"authors\":\"Serdar Erkol, Müge Güleli, Cem Çalışkan, Sevgi Kocaoba\",\"doi\":\"10.1177/14690667231217879\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Tiotropium Bromide is a long-acting bronchodilator that is used in the treatment of chronic obstructive pulmonary disease (COPD) and asthma bronchodilator or bronchiolitis, which are substances that expand the bronchi and reduce resistance in the respiratory tract and increase airflow to the lungs. For Tiotropium Bromide found in inhaler capsules to treat COPD, determining the relevant impurities G and H, which are not UV active, is crucial. For this purpose, a new and sensitive liquid chromatography triple-quadrupole mass spectrometry (LC-MS/MS) detection with electrospray ionization by using multiple reaction monitoring in the positive mode method was developed and validated. The identity of the compounds was supported by using LC-Q/TOF. All chromatographic studies were performed with a Zorbax Eclipse XDB-C8 (150 mm x 4.6 mm, 5.0 µm) column with a total injection time of 13 min at a flow rate of 0.4 ml/min as a gradient. The limit of detection (LOD) and limit of quantitation (LOQ) in the current study range were determined as 1.0 ppb and 2.5 ppb, respectively. The results of the validation parameters following the ICH Q2(R1) guideline were determined within the acceptance criteria.</p>\",\"PeriodicalId\":12007,\"journal\":{\"name\":\"European Journal of Mass Spectrometry\",\"volume\":\" \",\"pages\":\"76-83\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Mass Spectrometry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1177/14690667231217879\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/11/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, ATOMIC, MOLECULAR & CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Mass Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/14690667231217879","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/30 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PHYSICS, ATOMIC, MOLECULAR & CHEMICAL","Score":null,"Total":0}
引用次数: 0

摘要

噻托溴铵是一种长效支气管扩张剂,用于治疗慢性阻塞性肺疾病(COPD)和哮喘支气管扩张剂或细支气管炎,这是一种扩张支气管,减少呼吸道阻力,增加肺部气流的物质。对于用于治疗慢性阻塞性肺病的吸入胶囊中的噻托溴铵,确定不具有紫外线活性的相关杂质G和H至关重要。为此,建立了一种新的、灵敏的电喷雾电离液相色谱三重四极杆质谱(LC-MS/MS)检测方法,并对其进行了验证。通过LC-Q/TOF验证了化合物的性质。所有色谱研究均使用Zorbax Eclipse XDB-C8 (150 mm x 4.6 mm, 5.0µm)柱进行,总进样时间为13 min,流速为0.4 ml/min作为梯度。本研究范围内的检测限(LOD)和定量限(LOQ)分别为1.0 ppb和2.5 ppb。根据ICH Q2(R1)指南的验证参数的结果在验收标准内确定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simultaneous quantification of tiotropium bromide impurities G + H in capsule formulation by LC-MS/MS.

Tiotropium Bromide is a long-acting bronchodilator that is used in the treatment of chronic obstructive pulmonary disease (COPD) and asthma bronchodilator or bronchiolitis, which are substances that expand the bronchi and reduce resistance in the respiratory tract and increase airflow to the lungs. For Tiotropium Bromide found in inhaler capsules to treat COPD, determining the relevant impurities G and H, which are not UV active, is crucial. For this purpose, a new and sensitive liquid chromatography triple-quadrupole mass spectrometry (LC-MS/MS) detection with electrospray ionization by using multiple reaction monitoring in the positive mode method was developed and validated. The identity of the compounds was supported by using LC-Q/TOF. All chromatographic studies were performed with a Zorbax Eclipse XDB-C8 (150 mm x 4.6 mm, 5.0 µm) column with a total injection time of 13 min at a flow rate of 0.4 ml/min as a gradient. The limit of detection (LOD) and limit of quantitation (LOQ) in the current study range were determined as 1.0 ppb and 2.5 ppb, respectively. The results of the validation parameters following the ICH Q2(R1) guideline were determined within the acceptance criteria.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.40
自引率
7.70%
发文量
16
审稿时长
>12 weeks
期刊介绍: JMS - European Journal of Mass Spectrometry, is a peer-reviewed journal, devoted to the publication of innovative research in mass spectrometry. Articles in the journal come from proteomics, metabolomics, petroleomics and other areas developing under the umbrella of the “omic revolution”.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信