在反应系统中建立无需校准的热分析法并展示其先进的功能

IF 5 Q2 ENERGY & FUELS
Nicholas R. Jaramillo , Cole A. Ritchie , Michelle L. Pantoya , Igor Altman
{"title":"在反应系统中建立无需校准的热分析法并展示其先进的功能","authors":"Nicholas R. Jaramillo ,&nbsp;Cole A. Ritchie ,&nbsp;Michelle L. Pantoya ,&nbsp;Igor Altman","doi":"10.1016/j.jaecs.2023.100230","DOIUrl":null,"url":null,"abstract":"<div><p>A calibration-free multi-color pyrometry data analysis approach for determining the temporal change in the reciprocal temperature by only comparing the photomultiplier tube (PMT) responses to the system light emission is introduced. For Arrhenius reactions, analyzing the reciprocal temperature is particularly relevant for evaluating reactivity. The high accuracy of the proposed method is provided by eliminating the calibration step, which is made possible by considering the ratio of PMT signals as a function of time. The developed methodology is applicable to systems with continuous light emission spectra of the thermal nature that originate from condensed particulates. A demonstration of the data analysis approach was performed using aluminum powder burning in air. Four PMTs detected light emission during combustion that enabled analysis of six detector combinations to obtain a time-dependent signal ratio. Based on the temperature-dependent nature of light emission, the PMT response ratio provided the value of the reciprocal temperature change. All six detector combinations generated precisely coinciding results within time periods where the light emission trace behavior was relatively smooth that validated the data processing approach. It was also found that a non-smooth behavior of light emission led to significant deviations between outputs of different PMT combinations. This inconsistency between outputs was an indication of multi-temperature light emission whereas consistency between outputs corresponds to the single-temperature emission behavior. Using the calibration-free data processing approach, we isolated time periods where multi-temperature radiation is essential. Then, we further decoupled contributions from non-monotonic light emission signals and resolved two distinct temperatures responsible for observed radiation peculiarities.</p></div>","PeriodicalId":100104,"journal":{"name":"Applications in Energy and Combustion Science","volume":"16 ","pages":"Article 100230"},"PeriodicalIF":5.0000,"publicationDate":"2023-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666352X2300119X/pdfft?md5=8f52064160fe20dcb473dfd99bbf82b1&pid=1-s2.0-S2666352X2300119X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Establishing calibration-free pyrometry in reactive systems and demonstrating its advanced capabilities\",\"authors\":\"Nicholas R. Jaramillo ,&nbsp;Cole A. Ritchie ,&nbsp;Michelle L. Pantoya ,&nbsp;Igor Altman\",\"doi\":\"10.1016/j.jaecs.2023.100230\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A calibration-free multi-color pyrometry data analysis approach for determining the temporal change in the reciprocal temperature by only comparing the photomultiplier tube (PMT) responses to the system light emission is introduced. For Arrhenius reactions, analyzing the reciprocal temperature is particularly relevant for evaluating reactivity. The high accuracy of the proposed method is provided by eliminating the calibration step, which is made possible by considering the ratio of PMT signals as a function of time. The developed methodology is applicable to systems with continuous light emission spectra of the thermal nature that originate from condensed particulates. A demonstration of the data analysis approach was performed using aluminum powder burning in air. Four PMTs detected light emission during combustion that enabled analysis of six detector combinations to obtain a time-dependent signal ratio. Based on the temperature-dependent nature of light emission, the PMT response ratio provided the value of the reciprocal temperature change. All six detector combinations generated precisely coinciding results within time periods where the light emission trace behavior was relatively smooth that validated the data processing approach. It was also found that a non-smooth behavior of light emission led to significant deviations between outputs of different PMT combinations. This inconsistency between outputs was an indication of multi-temperature light emission whereas consistency between outputs corresponds to the single-temperature emission behavior. Using the calibration-free data processing approach, we isolated time periods where multi-temperature radiation is essential. Then, we further decoupled contributions from non-monotonic light emission signals and resolved two distinct temperatures responsible for observed radiation peculiarities.</p></div>\",\"PeriodicalId\":100104,\"journal\":{\"name\":\"Applications in Energy and Combustion Science\",\"volume\":\"16 \",\"pages\":\"Article 100230\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2023-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666352X2300119X/pdfft?md5=8f52064160fe20dcb473dfd99bbf82b1&pid=1-s2.0-S2666352X2300119X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applications in Energy and Combustion Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666352X2300119X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applications in Energy and Combustion Science","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666352X2300119X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

介绍了一种无需校准的多色热法数据分析方法,该方法仅通过比较光电倍增管(PMT)对系统光发射的响应来确定倒数温度的时间变化。对于阿伦尼乌斯反应,分析倒数温度对评价反应活性特别重要。通过考虑PMT信号与时间的比值,消除了校准步骤,从而保证了该方法的高精度。所开发的方法适用于由凝聚颗粒产生的热性质的连续光发射光谱系统。以铝粉在空气中燃烧为例,对数据分析方法进行了验证。四个pmt检测燃烧过程中的光发射,从而可以分析六个探测器组合,从而获得与时间相关的信号比。基于光发射的温度依赖特性,PMT响应比提供了温度变化的倒数值。所有六个探测器组合在光发射轨迹行为相对平滑的时间段内产生了精确一致的结果,验证了数据处理方法。研究还发现,光发射的非光滑行为导致不同PMT组合的输出之间存在显著偏差。输出之间的不一致性是多温度光发射的指示,而输出之间的一致性对应于单温度发射行为。使用无需校准的数据处理方法,我们隔离了需要多温度辐射的时间段。然后,我们进一步解耦了非单调光发射信号的贡献,并解决了造成观测到的辐射特性的两个不同温度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Establishing calibration-free pyrometry in reactive systems and demonstrating its advanced capabilities

A calibration-free multi-color pyrometry data analysis approach for determining the temporal change in the reciprocal temperature by only comparing the photomultiplier tube (PMT) responses to the system light emission is introduced. For Arrhenius reactions, analyzing the reciprocal temperature is particularly relevant for evaluating reactivity. The high accuracy of the proposed method is provided by eliminating the calibration step, which is made possible by considering the ratio of PMT signals as a function of time. The developed methodology is applicable to systems with continuous light emission spectra of the thermal nature that originate from condensed particulates. A demonstration of the data analysis approach was performed using aluminum powder burning in air. Four PMTs detected light emission during combustion that enabled analysis of six detector combinations to obtain a time-dependent signal ratio. Based on the temperature-dependent nature of light emission, the PMT response ratio provided the value of the reciprocal temperature change. All six detector combinations generated precisely coinciding results within time periods where the light emission trace behavior was relatively smooth that validated the data processing approach. It was also found that a non-smooth behavior of light emission led to significant deviations between outputs of different PMT combinations. This inconsistency between outputs was an indication of multi-temperature light emission whereas consistency between outputs corresponds to the single-temperature emission behavior. Using the calibration-free data processing approach, we isolated time periods where multi-temperature radiation is essential. Then, we further decoupled contributions from non-monotonic light emission signals and resolved two distinct temperatures responsible for observed radiation peculiarities.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.20
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信