[利用机械振动的实验HFV装置]。

K Takakuda, H Miyairi
{"title":"[利用机械振动的实验HFV装置]。","authors":"K Takakuda,&nbsp;H Miyairi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We make an experimental HFV apparatus in which the mass-spring system is utilized as the vibration actuator. When this apparatus is operated near the characteristic frequency of the mechanical vibration system, the efficiency is quite good and trivial motor is enough to realize the vibrating flow for the experimental ventilator. In this paper we first investigate the flow-frequency relations and found that above the characteristic frequency of the mechanical vibration system the oscillating volume of flow is nearly constant. Next we check the gas exchange between model-lung and atmosphere and obtain the relations among pressure vs. flow rate, pressure vs. rate of gas exchange.</p>","PeriodicalId":75958,"journal":{"name":"Iyo Kizai Kenkyujo hokoku. Reports of the Institute for Medical and Dental Engineering, Tokyo Medical and Dental University","volume":"23 ","pages":"91-6"},"PeriodicalIF":0.0000,"publicationDate":"1989-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Experimental HFV apparatus utilizing a mechanical vibration].\",\"authors\":\"K Takakuda,&nbsp;H Miyairi\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We make an experimental HFV apparatus in which the mass-spring system is utilized as the vibration actuator. When this apparatus is operated near the characteristic frequency of the mechanical vibration system, the efficiency is quite good and trivial motor is enough to realize the vibrating flow for the experimental ventilator. In this paper we first investigate the flow-frequency relations and found that above the characteristic frequency of the mechanical vibration system the oscillating volume of flow is nearly constant. Next we check the gas exchange between model-lung and atmosphere and obtain the relations among pressure vs. flow rate, pressure vs. rate of gas exchange.</p>\",\"PeriodicalId\":75958,\"journal\":{\"name\":\"Iyo Kizai Kenkyujo hokoku. Reports of the Institute for Medical and Dental Engineering, Tokyo Medical and Dental University\",\"volume\":\"23 \",\"pages\":\"91-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iyo Kizai Kenkyujo hokoku. Reports of the Institute for Medical and Dental Engineering, Tokyo Medical and Dental University\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iyo Kizai Kenkyujo hokoku. Reports of the Institute for Medical and Dental Engineering, Tokyo Medical and Dental University","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研制了一种以质量-弹簧系统作为振动执行器的高频振动实验装置。当该装置在机械振动系统的特征频率附近工作时,效率相当好,简单的电机就足以实现实验通风机的振动流。本文首先研究了流量与频率的关系,发现在机械振动系统的特征频率以上,流量的振荡体积几乎是恒定的。然后对模型肺与大气之间的气体交换进行了检验,得到了压力与流量、压力与气体交换速率的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Experimental HFV apparatus utilizing a mechanical vibration].

We make an experimental HFV apparatus in which the mass-spring system is utilized as the vibration actuator. When this apparatus is operated near the characteristic frequency of the mechanical vibration system, the efficiency is quite good and trivial motor is enough to realize the vibrating flow for the experimental ventilator. In this paper we first investigate the flow-frequency relations and found that above the characteristic frequency of the mechanical vibration system the oscillating volume of flow is nearly constant. Next we check the gas exchange between model-lung and atmosphere and obtain the relations among pressure vs. flow rate, pressure vs. rate of gas exchange.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信