显色试剂索林分光光度法测定人唾液中的锂

IF 1.2 4区 化学 Q3 CHEMISTRY, MULTIDISCIPLINARY
Stephen R. Levitt
{"title":"显色试剂索林分光光度法测定人唾液中的锂","authors":"Stephen R. Levitt","doi":"10.17344/acsi.2023.8121","DOIUrl":null,"url":null,"abstract":"The feasibility of using the chromogenic dye Thorin to spectrophotometrically measure lithium concentration in human saliva was explored. Absorbance wavelength maximum of the Li-Thorin complex was found to be 480 nm. Absorbance at 480 nm was obtained for saliva calibration standards containing 0.00–5.29 mEq/L of lithium. A least-squares fit produced a regression equation y = 0.128x + 1.449, R = 0.997. This was used to predict lithium concentrations in both artificially prepared lithium/saliva test solutions and in hospitalized patients treated with lithium. Results agree well with atomic absorption spectroscopy. Using a reagent blank with an equivalent amount of saliva as the test samples eliminated protein and electrolyte absorbance interference. This study supports the continued exploration of this method as a non-invasive point-of-care testing approach for monitoring saliva lithium in bipolar disorder.","PeriodicalId":7122,"journal":{"name":"Acta Chimica Slovenica","volume":"69 1","pages":"0"},"PeriodicalIF":1.2000,"publicationDate":"2023-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Spectrophotometric Measurement of Lithium in Human Saliva Using the Chromogenic Reagent Thorin\",\"authors\":\"Stephen R. Levitt\",\"doi\":\"10.17344/acsi.2023.8121\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The feasibility of using the chromogenic dye Thorin to spectrophotometrically measure lithium concentration in human saliva was explored. Absorbance wavelength maximum of the Li-Thorin complex was found to be 480 nm. Absorbance at 480 nm was obtained for saliva calibration standards containing 0.00–5.29 mEq/L of lithium. A least-squares fit produced a regression equation y = 0.128x + 1.449, R = 0.997. This was used to predict lithium concentrations in both artificially prepared lithium/saliva test solutions and in hospitalized patients treated with lithium. Results agree well with atomic absorption spectroscopy. Using a reagent blank with an equivalent amount of saliva as the test samples eliminated protein and electrolyte absorbance interference. This study supports the continued exploration of this method as a non-invasive point-of-care testing approach for monitoring saliva lithium in bipolar disorder.\",\"PeriodicalId\":7122,\"journal\":{\"name\":\"Acta Chimica Slovenica\",\"volume\":\"69 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Chimica Slovenica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17344/acsi.2023.8121\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chimica Slovenica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17344/acsi.2023.8121","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

探讨了用显色染料索林分光光度法测定人唾液中锂离子浓度的可行性。Li-Thorin配合物的最大吸光度波长为480 nm。含锂0.00-5.29 mEq/L的唾液标品在480 nm处获得吸光度。最小二乘拟合得到回归方程y = 0.128x + 1.449, R = 0.997。这被用于预测人工制备的锂/唾液测试溶液和接受锂治疗的住院患者中的锂浓度。结果与原子吸收光谱结果吻合较好。使用含有等量唾液的试剂空白作为测试样品,消除了蛋白质和电解质的吸收干扰。本研究支持继续探索该方法作为监测双相情感障碍患者唾液锂的非侵入性即时检测方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Spectrophotometric Measurement of Lithium in Human Saliva Using the Chromogenic Reagent Thorin
The feasibility of using the chromogenic dye Thorin to spectrophotometrically measure lithium concentration in human saliva was explored. Absorbance wavelength maximum of the Li-Thorin complex was found to be 480 nm. Absorbance at 480 nm was obtained for saliva calibration standards containing 0.00–5.29 mEq/L of lithium. A least-squares fit produced a regression equation y = 0.128x + 1.449, R = 0.997. This was used to predict lithium concentrations in both artificially prepared lithium/saliva test solutions and in hospitalized patients treated with lithium. Results agree well with atomic absorption spectroscopy. Using a reagent blank with an equivalent amount of saliva as the test samples eliminated protein and electrolyte absorbance interference. This study supports the continued exploration of this method as a non-invasive point-of-care testing approach for monitoring saliva lithium in bipolar disorder.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Chimica Slovenica
Acta Chimica Slovenica 化学-化学综合
CiteScore
2.50
自引率
25.00%
发文量
80
审稿时长
1.0 months
期刊介绍: Is an international, peer-reviewed and Open Access journal. It provides a forum for the publication of original scientific research in all fields of chemistry and closely related areas. Reviews, feature, scientific and technical articles, and short communications are welcome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信