光子诱导的x射线发射截面的实验测量

IF 1.4 3区 化学 Q4 CHEMISTRY, INORGANIC & NUCLEAR
Nabila Taïbouni, Arezki Amokrane, Tarek Azli, Ben Amor Mohammed Larbi, Naima Belouadah, Khelifa Boukeffoussa, Camelia Yasmine Medour, Hamza Zouad, Mohammed Messaoudi
{"title":"光子诱导的x射线发射截面的实验测量","authors":"Nabila Taïbouni, Arezki Amokrane, Tarek Azli, Ben Amor Mohammed Larbi, Naima Belouadah, Khelifa Boukeffoussa, Camelia Yasmine Medour, Hamza Zouad, Mohammed Messaoudi","doi":"10.1515/ract-2023-0179","DOIUrl":null,"url":null,"abstract":"Abstract The energy-dispersive X-ray fluorescence (ED-XRF) technique has been used for measurements of K α , K β , and total K X-rays emission cross sections induced by photons, as well as K-shell fluorescence yields for pure elements with 22 ⩽ Z ⩽ 49. These metals have been irradiated at 59.54 KeV excitation energy from an 241 Am annular radioactive source. The characteristic K X-rays emitted by the targets have been detected with a Silicon drift detector (SDD); the net areas of the K α and K β spectral peaks have been determined using the fitting process of PYMCA software. The obtained experimental values of the K X-ray fluorescence cross sections and the K-shell fluorescence yields were compared to the theoretical calculated ones and also to the experimental results obtained from a different experimental setup using a point source. The obtained values were between (6.84 ± 0.55 b/at.) and (891.0 ± 67.5 b/at.) for pure metals form Scandium to Indium. Experimental values were in good agreement with theoretical values within limits of uncertainty, as well as with the data reported in the literature. Moreover, the experimental determination of K X-ray fluorescence cross-section of scandium (Sc) at 59.54 KeV has not been preceded as far as we know. The value obtained is (6.84 ± 0.55 b/at). This new result obtained maybe contribute to the enrichment of the available databases.","PeriodicalId":21167,"journal":{"name":"Radiochimica Acta","volume":"23 1","pages":"0"},"PeriodicalIF":1.4000,"publicationDate":"2023-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental measurements of X-rays emission cross sections induced by photons\",\"authors\":\"Nabila Taïbouni, Arezki Amokrane, Tarek Azli, Ben Amor Mohammed Larbi, Naima Belouadah, Khelifa Boukeffoussa, Camelia Yasmine Medour, Hamza Zouad, Mohammed Messaoudi\",\"doi\":\"10.1515/ract-2023-0179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The energy-dispersive X-ray fluorescence (ED-XRF) technique has been used for measurements of K α , K β , and total K X-rays emission cross sections induced by photons, as well as K-shell fluorescence yields for pure elements with 22 ⩽ Z ⩽ 49. These metals have been irradiated at 59.54 KeV excitation energy from an 241 Am annular radioactive source. The characteristic K X-rays emitted by the targets have been detected with a Silicon drift detector (SDD); the net areas of the K α and K β spectral peaks have been determined using the fitting process of PYMCA software. The obtained experimental values of the K X-ray fluorescence cross sections and the K-shell fluorescence yields were compared to the theoretical calculated ones and also to the experimental results obtained from a different experimental setup using a point source. The obtained values were between (6.84 ± 0.55 b/at.) and (891.0 ± 67.5 b/at.) for pure metals form Scandium to Indium. Experimental values were in good agreement with theoretical values within limits of uncertainty, as well as with the data reported in the literature. Moreover, the experimental determination of K X-ray fluorescence cross-section of scandium (Sc) at 59.54 KeV has not been preceded as far as we know. The value obtained is (6.84 ± 0.55 b/at). This new result obtained maybe contribute to the enrichment of the available databases.\",\"PeriodicalId\":21167,\"journal\":{\"name\":\"Radiochimica Acta\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-09-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiochimica Acta\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/ract-2023-0179\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiochimica Acta","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/ract-2023-0179","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

摘要

利用能量色散x射线荧光(ED-XRF)技术测量了光子诱导的K α、K β和总K x射线发射截面,以及纯元素的K壳层荧光产率(22≤Z≤49)。这些金属以59.54 KeV的激发能从241 Am环形放射源照射。用硅漂移检测器(SDD)检测了目标发射的特征K x射线;利用PYMCA软件对K α和K β光谱峰的净面积进行了拟合。将得到的K- x射线荧光截面和K-壳层荧光产率的实验值与理论计算值进行了比较,并与使用点源的不同实验装置获得的实验结果进行了比较。从纯金属钪到铟,得到的值在(6.84±0.55 b/at.)和(891.0±67.5 b/at.)之间。在不确定度范围内,实验值与理论值以及文献中报道的数据一致。此外,据我们所知,在59.54 KeV下钪(Sc)的K x射线荧光截面的实验测定还没有先例。得到的值为(6.84±0.55 b/at)。这一新结果可能有助于丰富现有数据库。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental measurements of X-rays emission cross sections induced by photons
Abstract The energy-dispersive X-ray fluorescence (ED-XRF) technique has been used for measurements of K α , K β , and total K X-rays emission cross sections induced by photons, as well as K-shell fluorescence yields for pure elements with 22 ⩽ Z ⩽ 49. These metals have been irradiated at 59.54 KeV excitation energy from an 241 Am annular radioactive source. The characteristic K X-rays emitted by the targets have been detected with a Silicon drift detector (SDD); the net areas of the K α and K β spectral peaks have been determined using the fitting process of PYMCA software. The obtained experimental values of the K X-ray fluorescence cross sections and the K-shell fluorescence yields were compared to the theoretical calculated ones and also to the experimental results obtained from a different experimental setup using a point source. The obtained values were between (6.84 ± 0.55 b/at.) and (891.0 ± 67.5 b/at.) for pure metals form Scandium to Indium. Experimental values were in good agreement with theoretical values within limits of uncertainty, as well as with the data reported in the literature. Moreover, the experimental determination of K X-ray fluorescence cross-section of scandium (Sc) at 59.54 KeV has not been preceded as far as we know. The value obtained is (6.84 ± 0.55 b/at). This new result obtained maybe contribute to the enrichment of the available databases.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Radiochimica Acta
Radiochimica Acta 化学-核科学技术
CiteScore
2.90
自引率
16.70%
发文量
78
审稿时长
6 months
期刊介绍: Radiochimica Acta publishes manuscripts encompassing chemical aspects of nuclear science and technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信