Joel Irimpan, Rajesh Kesavan, Sunil Rajan, Lakshmi Kumar
{"title":"正常血压、高血压和低血压时无创与有创术中血压测量值的比较","authors":"Joel Irimpan, Rajesh Kesavan, Sunil Rajan, Lakshmi Kumar","doi":"10.4103/joacp.joacp_439_22","DOIUrl":null,"url":null,"abstract":"Abstract Background and Aims: Monitoring of intraoperative blood pressure (BP) is essential. We aimed to compare BP values simultaneously recorded by invasive and noninvasive methods under general anesthesia (GA) during normotension, hypertension, and hypotension. Mean arterial pressure (MAP) values calculated by the automated technique were also compared to the values obtained using predefined formula. Material and Methods: An observational, prospective study was conducted in 250 adult patients undergoing elective surgeries under GA. Before induction, noninvasive blood pressure (NIBP) was measured in the arm in a supine position using an automated oscillometer. Radial artery in the opposite arm was cannulated. NIBP and arterial BP (ABP) were recorded simultaneously during normotension, hypotension, and hypertension. Results: During normotension and hypertension, systolic BP (SBP) measured by NIBP and ABP were comparable. Diastolic BP (DBP) and MAP during normotension were significantly higher with NIBP (73.65 ± 7.73 vs. 65.69 ± 8.39 and 87.79 ± 8.43 vs. 84.24 ± 8.82, respectively). During hypertension, DBP and MAP were significantly higher with NIBP (90.44 ± 11.61 vs. 78.59 ± 11.09 and 111.67 ± 10.43 vs. 105.63 ± 11.06, respectively). During hypotension, SBP was significantly higher in ABP (91.14 ± 6.90 vs. 86.24 ± 6.06), and DBP and MAP were comparable. Comparison of MAP measured by ABP and NIBP techniques with the MAP calculated using predefined formula in normotension showed significantly higher values with the automated technique. Conclusions: During normotension and hypertension, DBP and MAP showed significantly higher values with the NIBP technique compared to ABP, with comparable SBP values. During hypotension, SBP showed significantly higher values with the ABP technique, with comparable DBP and MAP. MAP obtained using predefined formula and automated method in normotension was significantly higher with the automated technique.","PeriodicalId":14946,"journal":{"name":"Journal of Anaesthesiology, Clinical Pharmacology","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of intraoperative blood pressure values measured by noninvasive versus invasive methods during normotension, hypertension, and hypotension\",\"authors\":\"Joel Irimpan, Rajesh Kesavan, Sunil Rajan, Lakshmi Kumar\",\"doi\":\"10.4103/joacp.joacp_439_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Background and Aims: Monitoring of intraoperative blood pressure (BP) is essential. We aimed to compare BP values simultaneously recorded by invasive and noninvasive methods under general anesthesia (GA) during normotension, hypertension, and hypotension. Mean arterial pressure (MAP) values calculated by the automated technique were also compared to the values obtained using predefined formula. Material and Methods: An observational, prospective study was conducted in 250 adult patients undergoing elective surgeries under GA. Before induction, noninvasive blood pressure (NIBP) was measured in the arm in a supine position using an automated oscillometer. Radial artery in the opposite arm was cannulated. NIBP and arterial BP (ABP) were recorded simultaneously during normotension, hypotension, and hypertension. Results: During normotension and hypertension, systolic BP (SBP) measured by NIBP and ABP were comparable. Diastolic BP (DBP) and MAP during normotension were significantly higher with NIBP (73.65 ± 7.73 vs. 65.69 ± 8.39 and 87.79 ± 8.43 vs. 84.24 ± 8.82, respectively). During hypertension, DBP and MAP were significantly higher with NIBP (90.44 ± 11.61 vs. 78.59 ± 11.09 and 111.67 ± 10.43 vs. 105.63 ± 11.06, respectively). During hypotension, SBP was significantly higher in ABP (91.14 ± 6.90 vs. 86.24 ± 6.06), and DBP and MAP were comparable. Comparison of MAP measured by ABP and NIBP techniques with the MAP calculated using predefined formula in normotension showed significantly higher values with the automated technique. Conclusions: During normotension and hypertension, DBP and MAP showed significantly higher values with the NIBP technique compared to ABP, with comparable SBP values. During hypotension, SBP showed significantly higher values with the ABP technique, with comparable DBP and MAP. MAP obtained using predefined formula and automated method in normotension was significantly higher with the automated technique.\",\"PeriodicalId\":14946,\"journal\":{\"name\":\"Journal of Anaesthesiology, Clinical Pharmacology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Anaesthesiology, Clinical Pharmacology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/joacp.joacp_439_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Anaesthesiology, Clinical Pharmacology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/joacp.joacp_439_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
摘要
背景与目的:术中监测血压(BP)是必要的。我们的目的是比较在全身麻醉(GA)下,在正常血压、高血压和低血压期间,有创和无创方法同时记录的血压值。自动技术计算的平均动脉压(MAP)值也与使用预定义公式获得的值进行比较。材料和方法:一项观察性、前瞻性研究对250例在GA下接受择期手术的成年患者进行了研究。诱导前,在仰卧位使用自动振荡计测量手臂无创血压(NIBP)。对臂桡动脉插管。在正常血压、低血压和高血压时同时记录NIBP和动脉血压(ABP)。结果:在正常血压和高血压时,NIBP和ABP测量的收缩压(SBP)具有可比性。正常血压时舒张压(DBP)和MAP明显高于NIBP(分别为73.65±7.73 vs. 65.69±8.39和87.79±8.43 vs. 84.24±8.82)。高血压期间,DBP和MAP均明显高于NIBP(分别为90.44±11.61比78.59±11.09和111.67±10.43比105.63±11.06)。低血压时,收缩压与ABP显著升高(91.14±6.90比86.24±6.06),DBP与MAP具有可比性。用ABP和NIBP技术测量的MAP与用预定公式计算的MAP在正常血压下的比较显示,自动化技术的MAP值明显更高。结论:在正常血压和高血压期间,与ABP相比,NIBP技术显示的DBP和MAP值明显更高,收缩压值也相当。在低血压期间,ABP技术显示收缩压明显升高,DBP和MAP相当。在正常血压条件下,采用自动方法和预定义公式得到的MAP明显高于自动方法。
Comparison of intraoperative blood pressure values measured by noninvasive versus invasive methods during normotension, hypertension, and hypotension
Abstract Background and Aims: Monitoring of intraoperative blood pressure (BP) is essential. We aimed to compare BP values simultaneously recorded by invasive and noninvasive methods under general anesthesia (GA) during normotension, hypertension, and hypotension. Mean arterial pressure (MAP) values calculated by the automated technique were also compared to the values obtained using predefined formula. Material and Methods: An observational, prospective study was conducted in 250 adult patients undergoing elective surgeries under GA. Before induction, noninvasive blood pressure (NIBP) was measured in the arm in a supine position using an automated oscillometer. Radial artery in the opposite arm was cannulated. NIBP and arterial BP (ABP) were recorded simultaneously during normotension, hypotension, and hypertension. Results: During normotension and hypertension, systolic BP (SBP) measured by NIBP and ABP were comparable. Diastolic BP (DBP) and MAP during normotension were significantly higher with NIBP (73.65 ± 7.73 vs. 65.69 ± 8.39 and 87.79 ± 8.43 vs. 84.24 ± 8.82, respectively). During hypertension, DBP and MAP were significantly higher with NIBP (90.44 ± 11.61 vs. 78.59 ± 11.09 and 111.67 ± 10.43 vs. 105.63 ± 11.06, respectively). During hypotension, SBP was significantly higher in ABP (91.14 ± 6.90 vs. 86.24 ± 6.06), and DBP and MAP were comparable. Comparison of MAP measured by ABP and NIBP techniques with the MAP calculated using predefined formula in normotension showed significantly higher values with the automated technique. Conclusions: During normotension and hypertension, DBP and MAP showed significantly higher values with the NIBP technique compared to ABP, with comparable SBP values. During hypotension, SBP showed significantly higher values with the ABP technique, with comparable DBP and MAP. MAP obtained using predefined formula and automated method in normotension was significantly higher with the automated technique.
期刊介绍:
The JOACP publishes original peer-reviewed research and clinical work in all branches of anaesthesiology, pain, critical care and perioperative medicine including the application to basic sciences. In addition, the journal publishes review articles, special articles, brief communications/reports, case reports, and reports of new equipment, letters to editor, book reviews and obituaries. It is international in scope and comprehensive in coverage.