I.E. Ioshin, A.V. Rakova, I.V. Maksimov, E.A. Berezenko
{"title":"俄罗斯联邦总统办公室临床医院,莫斯科,俄罗斯联邦","authors":"I.E. Ioshin, A.V. Rakova, I.V. Maksimov, E.A. Berezenko","doi":"10.25276/0235-4160-2023-3-57-64","DOIUrl":null,"url":null,"abstract":"Purpose. To evaluate the safety and efficacy of different laser energy parameters when performing micropulse transscleral cyclophotocoagulation (MP-TSCPC) in patients with different stages of primary open-angle glaucoma (POAG). Material and methods. 177 patients with moderate (47) and advanced (130) stages of primary open-angle glaucoma were under observation. All patients underwent repeated laser (mean 1,3±0,6) and surgical (mean 1,78±0,7) penetrating and nonpenetrating antiglaucoma surgeries. According to the amount of total energy during MP-TSCPC, patients were divided into 2 groups. The protocol of the first group (117 patients) included a total energy of 125J, fluence of 121,8 J/cm² . The protocol of the second group included increased energy (60 patients) where the total energy was 150 J, fluence 152 J/cm² . Results. Surgery and postoperative period in all patients were areactive. According to the data obtained when comparing the two groups on Kaplan – Meier chart, after 12 months of observation the group of patients with the fluence of 152J/cm² showed better results. A positive result was achieved in 95% of cases, compared to 87,1% in patients in the first group with an fluence of 121,8 J/cm². Conclusion. MP-TSCPC in patients with POAG with a fluence of 121,8 J/сm² and a total energy of 125 J and a fluence of 152 J/сm² and a total energy of 150 J is an effective and safe treatment method. The success parameters evaluated according to the Kaplan – Meier criterion showed that performing MP-TSCPC with 150 J energy was more effective than with 125 J. In the first group, 87,1% (102 out of 117 patients) success was achieved in up to 12 months of follow-up. In 60 patients with a higher energy (150 J), MP-TSCPC resulted in a long-term hypotensive effect in 95% (57 out of 60 patients) in the same period of observation. Key words: open angle glaucoma, intraocular pressure, micropulse cyclophotocoagulation, fluence","PeriodicalId":52983,"journal":{"name":"Oftal''mokhirurgiia","volume":"281 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical Hospital of the Office of the President of the Russian Federation, Moscow, Russian Federation\",\"authors\":\"I.E. Ioshin, A.V. Rakova, I.V. Maksimov, E.A. Berezenko\",\"doi\":\"10.25276/0235-4160-2023-3-57-64\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose. To evaluate the safety and efficacy of different laser energy parameters when performing micropulse transscleral cyclophotocoagulation (MP-TSCPC) in patients with different stages of primary open-angle glaucoma (POAG). Material and methods. 177 patients with moderate (47) and advanced (130) stages of primary open-angle glaucoma were under observation. All patients underwent repeated laser (mean 1,3±0,6) and surgical (mean 1,78±0,7) penetrating and nonpenetrating antiglaucoma surgeries. According to the amount of total energy during MP-TSCPC, patients were divided into 2 groups. The protocol of the first group (117 patients) included a total energy of 125J, fluence of 121,8 J/cm² . The protocol of the second group included increased energy (60 patients) where the total energy was 150 J, fluence 152 J/cm² . Results. Surgery and postoperative period in all patients were areactive. According to the data obtained when comparing the two groups on Kaplan – Meier chart, after 12 months of observation the group of patients with the fluence of 152J/cm² showed better results. A positive result was achieved in 95% of cases, compared to 87,1% in patients in the first group with an fluence of 121,8 J/cm². Conclusion. MP-TSCPC in patients with POAG with a fluence of 121,8 J/сm² and a total energy of 125 J and a fluence of 152 J/сm² and a total energy of 150 J is an effective and safe treatment method. The success parameters evaluated according to the Kaplan – Meier criterion showed that performing MP-TSCPC with 150 J energy was more effective than with 125 J. In the first group, 87,1% (102 out of 117 patients) success was achieved in up to 12 months of follow-up. In 60 patients with a higher energy (150 J), MP-TSCPC resulted in a long-term hypotensive effect in 95% (57 out of 60 patients) in the same period of observation. Key words: open angle glaucoma, intraocular pressure, micropulse cyclophotocoagulation, fluence\",\"PeriodicalId\":52983,\"journal\":{\"name\":\"Oftal''mokhirurgiia\",\"volume\":\"281 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oftal''mokhirurgiia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25276/0235-4160-2023-3-57-64\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oftal''mokhirurgiia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25276/0235-4160-2023-3-57-64","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Clinical Hospital of the Office of the President of the Russian Federation, Moscow, Russian Federation
Purpose. To evaluate the safety and efficacy of different laser energy parameters when performing micropulse transscleral cyclophotocoagulation (MP-TSCPC) in patients with different stages of primary open-angle glaucoma (POAG). Material and methods. 177 patients with moderate (47) and advanced (130) stages of primary open-angle glaucoma were under observation. All patients underwent repeated laser (mean 1,3±0,6) and surgical (mean 1,78±0,7) penetrating and nonpenetrating antiglaucoma surgeries. According to the amount of total energy during MP-TSCPC, patients were divided into 2 groups. The protocol of the first group (117 patients) included a total energy of 125J, fluence of 121,8 J/cm² . The protocol of the second group included increased energy (60 patients) where the total energy was 150 J, fluence 152 J/cm² . Results. Surgery and postoperative period in all patients were areactive. According to the data obtained when comparing the two groups on Kaplan – Meier chart, after 12 months of observation the group of patients with the fluence of 152J/cm² showed better results. A positive result was achieved in 95% of cases, compared to 87,1% in patients in the first group with an fluence of 121,8 J/cm². Conclusion. MP-TSCPC in patients with POAG with a fluence of 121,8 J/сm² and a total energy of 125 J and a fluence of 152 J/сm² and a total energy of 150 J is an effective and safe treatment method. The success parameters evaluated according to the Kaplan – Meier criterion showed that performing MP-TSCPC with 150 J energy was more effective than with 125 J. In the first group, 87,1% (102 out of 117 patients) success was achieved in up to 12 months of follow-up. In 60 patients with a higher energy (150 J), MP-TSCPC resulted in a long-term hypotensive effect in 95% (57 out of 60 patients) in the same period of observation. Key words: open angle glaucoma, intraocular pressure, micropulse cyclophotocoagulation, fluence