Angelia Maleah Holland-Winkler, Andrew R. Moore, Jenna K. Ansley, Noah A. Fritz, Ilya Bederman
{"title":"健康人血液计与气相色谱-质谱法测定β -羟基丁酸的差异","authors":"Angelia Maleah Holland-Winkler, Andrew R. Moore, Jenna K. Ansley, Noah A. Fritz, Ilya Bederman","doi":"10.3390/muscles2040025","DOIUrl":null,"url":null,"abstract":"Ketone salt (KS) supplementation induces temporary nutritional ketosis to achieve potential exercise performance and health benefits. Racemic KS includes both D/L isomers of β-hydroxybutyrate, yet commercially available measurement devices (i.e., blood meters) only measure the D variant. The aim of this study was to investigate the efficacy of a blood meter to measure serum β-hydroxybutyrate in comparison with gas chromatography–mass spectrometry (GC-MS) before and 30 min after consuming a placebo or racemic KS. In this triple-blinded cross-over study, 16 healthy adults were administered either a placebo or KS drink, and the circulating β-hydroxybutyrate concentration was measured at baseline (PRE) and 30 min following consumption (POST) using a blood ketone meter and by GC-MS. Compared to the placebo, both GC-MS and the blood meter obtained significantly greater β-hydroxybutyrate levels from PRE to POST time-points after consuming KS. Additionally, GC-MS results showed significantly higher levels of β-hydroxybutyrate with both the placebo and KS at PRE and POST time-points, as compared to the blood meter. These results indicate that (1) even in the absence of KS, the blood meter yields significantly lower β-hydroxybutyrate values than GC-MS, and (2) the inability of the blood meter to measure L-β-hydroxybutyrate values POST KS warrants the further development of publicly available ketone measurement apparatuses.","PeriodicalId":46318,"journal":{"name":"MLTJ-Muscles Ligaments and Tendons Journal","volume":"20 1","pages":"0"},"PeriodicalIF":0.5000,"publicationDate":"2023-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Discrepancy of Beta-Hydroxybutyrate Measurements between a Blood Meter and GC-MS Methods in Healthy Humans\",\"authors\":\"Angelia Maleah Holland-Winkler, Andrew R. Moore, Jenna K. Ansley, Noah A. Fritz, Ilya Bederman\",\"doi\":\"10.3390/muscles2040025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ketone salt (KS) supplementation induces temporary nutritional ketosis to achieve potential exercise performance and health benefits. Racemic KS includes both D/L isomers of β-hydroxybutyrate, yet commercially available measurement devices (i.e., blood meters) only measure the D variant. The aim of this study was to investigate the efficacy of a blood meter to measure serum β-hydroxybutyrate in comparison with gas chromatography–mass spectrometry (GC-MS) before and 30 min after consuming a placebo or racemic KS. In this triple-blinded cross-over study, 16 healthy adults were administered either a placebo or KS drink, and the circulating β-hydroxybutyrate concentration was measured at baseline (PRE) and 30 min following consumption (POST) using a blood ketone meter and by GC-MS. Compared to the placebo, both GC-MS and the blood meter obtained significantly greater β-hydroxybutyrate levels from PRE to POST time-points after consuming KS. Additionally, GC-MS results showed significantly higher levels of β-hydroxybutyrate with both the placebo and KS at PRE and POST time-points, as compared to the blood meter. These results indicate that (1) even in the absence of KS, the blood meter yields significantly lower β-hydroxybutyrate values than GC-MS, and (2) the inability of the blood meter to measure L-β-hydroxybutyrate values POST KS warrants the further development of publicly available ketone measurement apparatuses.\",\"PeriodicalId\":46318,\"journal\":{\"name\":\"MLTJ-Muscles Ligaments and Tendons Journal\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MLTJ-Muscles Ligaments and Tendons Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/muscles2040025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MLTJ-Muscles Ligaments and Tendons Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/muscles2040025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Discrepancy of Beta-Hydroxybutyrate Measurements between a Blood Meter and GC-MS Methods in Healthy Humans
Ketone salt (KS) supplementation induces temporary nutritional ketosis to achieve potential exercise performance and health benefits. Racemic KS includes both D/L isomers of β-hydroxybutyrate, yet commercially available measurement devices (i.e., blood meters) only measure the D variant. The aim of this study was to investigate the efficacy of a blood meter to measure serum β-hydroxybutyrate in comparison with gas chromatography–mass spectrometry (GC-MS) before and 30 min after consuming a placebo or racemic KS. In this triple-blinded cross-over study, 16 healthy adults were administered either a placebo or KS drink, and the circulating β-hydroxybutyrate concentration was measured at baseline (PRE) and 30 min following consumption (POST) using a blood ketone meter and by GC-MS. Compared to the placebo, both GC-MS and the blood meter obtained significantly greater β-hydroxybutyrate levels from PRE to POST time-points after consuming KS. Additionally, GC-MS results showed significantly higher levels of β-hydroxybutyrate with both the placebo and KS at PRE and POST time-points, as compared to the blood meter. These results indicate that (1) even in the absence of KS, the blood meter yields significantly lower β-hydroxybutyrate values than GC-MS, and (2) the inability of the blood meter to measure L-β-hydroxybutyrate values POST KS warrants the further development of publicly available ketone measurement apparatuses.
期刊介绍:
MLTJ (Muscle, Ligaments and Tendons Journal) is an open access, peer-reviewed online journal that encompasses all aspects of clinical and basic research studies related to musculoskeletal, ligament, tendon, public health, exercise physiology and kinesiology issues. Muscle, Ligaments and Tendons Journal (MLTJ) provides the platform for exchange of new clinical and scientific information in the most precise and expeditious way to achieve timely dissemination of information and cross-fertilization of ideas. It is the official journal of the Italian Society of Muscles, Ligaments and Tendons (I.S.Mu.L.T.), Società Italiana Terapia con Onde D’urto (S.I.T.O.D.) and Società Italiana Studio Piede e Caviglia (S.I.S.P.E.C)