抽油机输出参数对污染物排放影响程度的研究

A. A. Terekhov, F. F. Huaman, E. G. Telyashev, S. M. Mavlyutova, I. D. Bespalov, А. А. Galimov, V. A. Kupavyh
{"title":"抽油机输出参数对污染物排放影响程度的研究","authors":"A. A. Terekhov, F. F. Huaman, E. G. Telyashev, S. M. Mavlyutova, I. D. Bespalov, А. А. Galimov, V. A. Kupavyh","doi":"10.17122/ntj-oil-2023-4-220-236","DOIUrl":null,"url":null,"abstract":"Gas turbine plants, as well as all types of gas-using equipment, have a long service life, during which, along with the operational performance deterioration, pollutant emissions are expected to change.
 To take this factor into account, when developing algorithms for determining pollutant emissions from gas pumping units based on operational parameters, an analysis of changes in NOx and COx emissions (nitrogen oxides and carbon oxides) when the output parameters of the gas pumping unit deviates from the nominal ones has been carried out.
 The impact of operating time, repairs of the drive motor, flushing of the AL-31ST flow section was investigated.
 Additional tests to simulate the reduction in the available power of the unit due to a decrease in the efficiency of the axial compressor, which made it possible to quantify the impact of the deterioration in the technical condition of the gas turbine plant on NOx and COx emission were carried out.","PeriodicalId":493832,"journal":{"name":"Problemy sbora, podgotovki i transporta nefti i nefteproduktov","volume":"138 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"STUDY OF INFLUENCE DEGREE OF GAS PUMPING UNIT OUTPUT PARAMETERS ON POLLUTANT EMISSION\",\"authors\":\"A. A. Terekhov, F. F. Huaman, E. G. Telyashev, S. M. Mavlyutova, I. D. Bespalov, А. А. Galimov, V. A. Kupavyh\",\"doi\":\"10.17122/ntj-oil-2023-4-220-236\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Gas turbine plants, as well as all types of gas-using equipment, have a long service life, during which, along with the operational performance deterioration, pollutant emissions are expected to change.
 To take this factor into account, when developing algorithms for determining pollutant emissions from gas pumping units based on operational parameters, an analysis of changes in NOx and COx emissions (nitrogen oxides and carbon oxides) when the output parameters of the gas pumping unit deviates from the nominal ones has been carried out.
 The impact of operating time, repairs of the drive motor, flushing of the AL-31ST flow section was investigated.
 Additional tests to simulate the reduction in the available power of the unit due to a decrease in the efficiency of the axial compressor, which made it possible to quantify the impact of the deterioration in the technical condition of the gas turbine plant on NOx and COx emission were carried out.\",\"PeriodicalId\":493832,\"journal\":{\"name\":\"Problemy sbora, podgotovki i transporta nefti i nefteproduktov\",\"volume\":\"138 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Problemy sbora, podgotovki i transporta nefti i nefteproduktov\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17122/ntj-oil-2023-4-220-236\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Problemy sbora, podgotovki i transporta nefti i nefteproduktov","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17122/ntj-oil-2023-4-220-236","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

燃气轮机装置以及各类用气设备的使用寿命都很长,在此期间,随着运行性能的恶化,污染物排放量有望发生变化。 考虑到这一因素,在开发基于运行参数确定燃气抽油机污染物排放的算法时,对燃气抽油机输出参数偏离标称参数时NOx和COx(氮氧化物和碳氧化物)排放的变化进行了分析。 考察了操作时间、驱动电机维修、al -31流段冲洗等因素的影响。另外还进行了一些试验,模拟由于轴向压气机效率降低而导致机组可用功率减少的情况,从而可以量化燃气轮机装置技术条件恶化对NOx和COx排放的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
STUDY OF INFLUENCE DEGREE OF GAS PUMPING UNIT OUTPUT PARAMETERS ON POLLUTANT EMISSION
Gas turbine plants, as well as all types of gas-using equipment, have a long service life, during which, along with the operational performance deterioration, pollutant emissions are expected to change. To take this factor into account, when developing algorithms for determining pollutant emissions from gas pumping units based on operational parameters, an analysis of changes in NOx and COx emissions (nitrogen oxides and carbon oxides) when the output parameters of the gas pumping unit deviates from the nominal ones has been carried out. The impact of operating time, repairs of the drive motor, flushing of the AL-31ST flow section was investigated. Additional tests to simulate the reduction in the available power of the unit due to a decrease in the efficiency of the axial compressor, which made it possible to quantify the impact of the deterioration in the technical condition of the gas turbine plant on NOx and COx emission were carried out.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信