Moussa Toudou-Daouda, Nicolas Chausson, Didier Smadja, Cosmin Alecu
{"title":"脑卒中患者中重度大脑中动脉粥样硬化性狭窄的检测:经颅彩色编码双工超声与计算机断层血管造影","authors":"Moussa Toudou-Daouda, Nicolas Chausson, Didier Smadja, Cosmin Alecu","doi":"10.1177/1742271x231195723","DOIUrl":null,"url":null,"abstract":"Background: Intracranial atherosclerotic stenosis is a common cause of ischemic cerebrovascular events and is associated with a high risk of stroke recurrence. This study aimed to assess the diagnostic accuracy of transcranial color-coded duplex sonography for moderate-to-severe middle cerebral artery stenosis in stroke patients. Methods: A retrospective analysis was carried out, including 31 patients aged ⩾18 years hospitalized for ischemic cerebrovascular event in whom middle cerebral artery stenosis ⩾30% was identified on computed tomography angiography. Transcranial color-coded duplex sonography findings were compared to the degree of stenosis blindly identified on the computed tomography angiography used as the reference method. Results: Overall, 27 patients had M1 stenosis and the other 4 had M2 stenosis. To detect M2 stenosis ⩾ 50% and ⩾ 70%, stenotic to pre-stenotic ratio ⩾ 2 and ⩾ 3 had a sensitivity of 100%, respectively. To detect M1 stenosis ⩾ 70%, peak systolic velocity ⩾ 300 cm/s had a sensitivity of 53.8% and specificity of 85.7% with area under the receiver-operating characteristic curve of 0.753 (95% confidence interval: 0.568–0.938; p = 0.026), and stenotic to pre-stenotic ratio ⩾ 3 had a sensitivity of 84.6% and a specificity of 78.6% (area under the curve = 0.854; 95% confidence interval: 0.707–1; p = 0.002). Middle cerebral artery/anterior cerebral artery velocity ratio < 0.7 had a sensitivity of 57.1% and specificity of 90% to detect dampened pre-stenotic flow in middle cerebral artery secondary to downstream M1 stenosis ⩾ 70% (area under the curve = 0.800; 95% confidence interval: 0.584–1; p = 0.040). This study showed that stenotic to pre-stenotic ratio ⩾ 3 was more sensitive than peak systolic velocity ⩾ 300 cm/s to screen M1 stenosis ⩾ 70%. Middle cerebral artery/anterior cerebral artery ratio < 0.7 was a good indirect sign to detect dampened pre-stenotic flow due to M1 stenosis ⩾ 70%.","PeriodicalId":23440,"journal":{"name":"Ultrasound","volume":"355 1","pages":"0"},"PeriodicalIF":0.8000,"publicationDate":"2023-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Detection of moderate to severe middle cerebral artery atherosclerotic stenosis in stroke patients: Transcranial color-coded duplex sonography versus computed tomography angiography\",\"authors\":\"Moussa Toudou-Daouda, Nicolas Chausson, Didier Smadja, Cosmin Alecu\",\"doi\":\"10.1177/1742271x231195723\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Intracranial atherosclerotic stenosis is a common cause of ischemic cerebrovascular events and is associated with a high risk of stroke recurrence. This study aimed to assess the diagnostic accuracy of transcranial color-coded duplex sonography for moderate-to-severe middle cerebral artery stenosis in stroke patients. Methods: A retrospective analysis was carried out, including 31 patients aged ⩾18 years hospitalized for ischemic cerebrovascular event in whom middle cerebral artery stenosis ⩾30% was identified on computed tomography angiography. Transcranial color-coded duplex sonography findings were compared to the degree of stenosis blindly identified on the computed tomography angiography used as the reference method. Results: Overall, 27 patients had M1 stenosis and the other 4 had M2 stenosis. To detect M2 stenosis ⩾ 50% and ⩾ 70%, stenotic to pre-stenotic ratio ⩾ 2 and ⩾ 3 had a sensitivity of 100%, respectively. To detect M1 stenosis ⩾ 70%, peak systolic velocity ⩾ 300 cm/s had a sensitivity of 53.8% and specificity of 85.7% with area under the receiver-operating characteristic curve of 0.753 (95% confidence interval: 0.568–0.938; p = 0.026), and stenotic to pre-stenotic ratio ⩾ 3 had a sensitivity of 84.6% and a specificity of 78.6% (area under the curve = 0.854; 95% confidence interval: 0.707–1; p = 0.002). Middle cerebral artery/anterior cerebral artery velocity ratio < 0.7 had a sensitivity of 57.1% and specificity of 90% to detect dampened pre-stenotic flow in middle cerebral artery secondary to downstream M1 stenosis ⩾ 70% (area under the curve = 0.800; 95% confidence interval: 0.584–1; p = 0.040). This study showed that stenotic to pre-stenotic ratio ⩾ 3 was more sensitive than peak systolic velocity ⩾ 300 cm/s to screen M1 stenosis ⩾ 70%. Middle cerebral artery/anterior cerebral artery ratio < 0.7 was a good indirect sign to detect dampened pre-stenotic flow due to M1 stenosis ⩾ 70%.\",\"PeriodicalId\":23440,\"journal\":{\"name\":\"Ultrasound\",\"volume\":\"355 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1742271x231195723\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1742271x231195723","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Detection of moderate to severe middle cerebral artery atherosclerotic stenosis in stroke patients: Transcranial color-coded duplex sonography versus computed tomography angiography
Background: Intracranial atherosclerotic stenosis is a common cause of ischemic cerebrovascular events and is associated with a high risk of stroke recurrence. This study aimed to assess the diagnostic accuracy of transcranial color-coded duplex sonography for moderate-to-severe middle cerebral artery stenosis in stroke patients. Methods: A retrospective analysis was carried out, including 31 patients aged ⩾18 years hospitalized for ischemic cerebrovascular event in whom middle cerebral artery stenosis ⩾30% was identified on computed tomography angiography. Transcranial color-coded duplex sonography findings were compared to the degree of stenosis blindly identified on the computed tomography angiography used as the reference method. Results: Overall, 27 patients had M1 stenosis and the other 4 had M2 stenosis. To detect M2 stenosis ⩾ 50% and ⩾ 70%, stenotic to pre-stenotic ratio ⩾ 2 and ⩾ 3 had a sensitivity of 100%, respectively. To detect M1 stenosis ⩾ 70%, peak systolic velocity ⩾ 300 cm/s had a sensitivity of 53.8% and specificity of 85.7% with area under the receiver-operating characteristic curve of 0.753 (95% confidence interval: 0.568–0.938; p = 0.026), and stenotic to pre-stenotic ratio ⩾ 3 had a sensitivity of 84.6% and a specificity of 78.6% (area under the curve = 0.854; 95% confidence interval: 0.707–1; p = 0.002). Middle cerebral artery/anterior cerebral artery velocity ratio < 0.7 had a sensitivity of 57.1% and specificity of 90% to detect dampened pre-stenotic flow in middle cerebral artery secondary to downstream M1 stenosis ⩾ 70% (area under the curve = 0.800; 95% confidence interval: 0.584–1; p = 0.040). This study showed that stenotic to pre-stenotic ratio ⩾ 3 was more sensitive than peak systolic velocity ⩾ 300 cm/s to screen M1 stenosis ⩾ 70%. Middle cerebral artery/anterior cerebral artery ratio < 0.7 was a good indirect sign to detect dampened pre-stenotic flow due to M1 stenosis ⩾ 70%.
UltrasoundRADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.70
自引率
0.00%
发文量
55
期刊介绍:
Ultrasound is the official journal of the British Medical Ultrasound Society (BMUS), a multidisciplinary, charitable society comprising radiologists, obstetricians, sonographers, physicists and veterinarians amongst others.