肌肉刺激外周静脉氧饱和度估计使用光体积脉搏图:概念证明

Q4 Engineering
Idoia Badiola, Chenglin Lyu, Arne Ferchland, Fabian Comes, Vladimir Blazek, Steffen Leonhardt, Markus Lueken
{"title":"肌肉刺激外周静脉氧饱和度估计使用光体积脉搏图:概念证明","authors":"Idoia Badiola, Chenglin Lyu, Arne Ferchland, Fabian Comes, Vladimir Blazek, Steffen Leonhardt, Markus Lueken","doi":"10.1515/cdbme-2023-1037","DOIUrl":null,"url":null,"abstract":"Abstract The body’s ability to balance oxygen supply and demand can be compromised in conditions such as shock, sepsis, and heart failure. Thus, measuring venous oxygen saturation (SvO2) simultaneously with the well-established peripheral arterial oxygen saturation can help in the clinical management of these conditions. Some authors have suggested a non-invasive SvO2 estimation method that acquires venous blood volume variations generated through the calf muscle pump using photoplethysmography (PPG): the Venous Muscle Pump Test (VMPT). However, the technique presents significant variability in the rhythm and speed of the foot dorsal flexions needed for the VMPT and cannot be performed on unconscious subjects and those with reduced mobility. This study proposes using functional electrical stimulation (FES) to stimulate the calf muscle and generate rhythmic and reproducible muscle contractions. A human proof-of-concept study was conducted with three healthy young male participants. The PPG signals achieved through the VMPT with conventionally active and FES-induced movements were compared. We found that FES-induced movement produced reproducible venous blood volume variations comparable to the ones induced by the active movement. However, it also leads to lower venous refilling time and lower muscle power. Although further individualized tuning of the stimulation parameters is needed to achieve more conclusive results, FES-induced movement proves to be a promising alternative to the conventional VMPT technique to measure venous oxygen saturation and assess venous insufficiency in specific clinical situations.","PeriodicalId":10739,"journal":{"name":"Current Directions in Biomedical Engineering","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Muscle stimulation for peripheral venous oxygen saturation estimation using photoplethysmography: a proof-of-concept\",\"authors\":\"Idoia Badiola, Chenglin Lyu, Arne Ferchland, Fabian Comes, Vladimir Blazek, Steffen Leonhardt, Markus Lueken\",\"doi\":\"10.1515/cdbme-2023-1037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The body’s ability to balance oxygen supply and demand can be compromised in conditions such as shock, sepsis, and heart failure. Thus, measuring venous oxygen saturation (SvO2) simultaneously with the well-established peripheral arterial oxygen saturation can help in the clinical management of these conditions. Some authors have suggested a non-invasive SvO2 estimation method that acquires venous blood volume variations generated through the calf muscle pump using photoplethysmography (PPG): the Venous Muscle Pump Test (VMPT). However, the technique presents significant variability in the rhythm and speed of the foot dorsal flexions needed for the VMPT and cannot be performed on unconscious subjects and those with reduced mobility. This study proposes using functional electrical stimulation (FES) to stimulate the calf muscle and generate rhythmic and reproducible muscle contractions. A human proof-of-concept study was conducted with three healthy young male participants. The PPG signals achieved through the VMPT with conventionally active and FES-induced movements were compared. We found that FES-induced movement produced reproducible venous blood volume variations comparable to the ones induced by the active movement. However, it also leads to lower venous refilling time and lower muscle power. Although further individualized tuning of the stimulation parameters is needed to achieve more conclusive results, FES-induced movement proves to be a promising alternative to the conventional VMPT technique to measure venous oxygen saturation and assess venous insufficiency in specific clinical situations.\",\"PeriodicalId\":10739,\"journal\":{\"name\":\"Current Directions in Biomedical Engineering\",\"volume\":\"78 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Directions in Biomedical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/cdbme-2023-1037\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Directions in Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cdbme-2023-1037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

在休克、败血症和心力衰竭等情况下,机体平衡氧气供应和需求的能力会受到损害。因此,测量静脉氧饱和度(SvO2)同时建立外周动脉氧饱和度可以帮助这些疾病的临床管理。一些作者提出了一种无创的SvO2估计方法,该方法使用光容积描记术(PPG)获取小腿肌肉泵产生的静脉血容量变化:静脉肌肉泵试验(VMPT)。然而,该技术在VMPT所需的足背屈曲的节奏和速度方面存在显著的可变性,不能用于无意识和活动能力降低的受试者。本研究建议使用功能性电刺激(FES)来刺激小腿肌肉,并产生有节奏和可重复的肌肉收缩。对三名健康的年轻男性进行了一项人体概念验证研究。通过VMPT获得的PPG信号与常规活动和fes诱导的运动进行了比较。我们发现fes诱导的运动产生了可重复的静脉血容量变化,与主动运动引起的变化相当。然而,它也会导致静脉再填充时间缩短和肌肉力量降低。虽然需要进一步个性化调整刺激参数以获得更确切的结果,但fes诱导的运动被证明是传统VMPT技术在特定临床情况下测量静脉氧饱和度和评估静脉功能不全的有希望的替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Muscle stimulation for peripheral venous oxygen saturation estimation using photoplethysmography: a proof-of-concept
Abstract The body’s ability to balance oxygen supply and demand can be compromised in conditions such as shock, sepsis, and heart failure. Thus, measuring venous oxygen saturation (SvO2) simultaneously with the well-established peripheral arterial oxygen saturation can help in the clinical management of these conditions. Some authors have suggested a non-invasive SvO2 estimation method that acquires venous blood volume variations generated through the calf muscle pump using photoplethysmography (PPG): the Venous Muscle Pump Test (VMPT). However, the technique presents significant variability in the rhythm and speed of the foot dorsal flexions needed for the VMPT and cannot be performed on unconscious subjects and those with reduced mobility. This study proposes using functional electrical stimulation (FES) to stimulate the calf muscle and generate rhythmic and reproducible muscle contractions. A human proof-of-concept study was conducted with three healthy young male participants. The PPG signals achieved through the VMPT with conventionally active and FES-induced movements were compared. We found that FES-induced movement produced reproducible venous blood volume variations comparable to the ones induced by the active movement. However, it also leads to lower venous refilling time and lower muscle power. Although further individualized tuning of the stimulation parameters is needed to achieve more conclusive results, FES-induced movement proves to be a promising alternative to the conventional VMPT technique to measure venous oxygen saturation and assess venous insufficiency in specific clinical situations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Directions in Biomedical Engineering
Current Directions in Biomedical Engineering Engineering-Biomedical Engineering
CiteScore
0.90
自引率
0.00%
发文量
239
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信