儿童人工耳蜗植入术后电诱发复合动作电位及其与耳蜗神经直径的关系

Aparna Das, Arun Alexander, Anuprasad Sreenivasan, Sivaraman Ganesan
{"title":"儿童人工耳蜗植入术后电诱发复合动作电位及其与耳蜗神经直径的关系","authors":"Aparna Das, Arun Alexander, Anuprasad Sreenivasan, Sivaraman Ganesan","doi":"10.18203/issn.2454-5929.ijohns20233215","DOIUrl":null,"url":null,"abstract":"Background: The study evaluated changes in the threshold of ECAP recorded during cochlear implantation, at switch on, after three months and six months following cochlear implantation. It further assessed the correlation between the ECAP threshold with T and C levels and the cochlear nerve diameter measured preoperatively. Methods: A prospective study of 42 prelingually deaf children who underwent cochlear implantation was conducted. The ECAP threshold values intra-operatively, at switch on, three months and six months were recorded and analysed. The T and C levels were assessed six months postoperatively, and correlation with the ECAP threshold was analysed. The diameter of the cochlear nerve was recorded, and its correlation with the ECAP threshold was determined. Results: Over six months, the basal, central and apical electrodes showed a statistically significant reduction in ECAP threshold of 11.64%, 4.67% and 25.81%, respectively, in candidates implanted with Advanced Bionics implant and 18.89%, 12.78% and 14.08%, respectively in candidates implanted with Nucleus implant. The ECAP thresholds were lower for the apical electrodes. No correlation was found between the ECAP threshold and T and C levels. A correlation between the cochlear nerve diameter and ECAP was not statistically significant. Conclusions: There was a statistically significant change in the ECAP threshold over six months. There was no statistically significant correlation between the ECAP thresholds and T and C levels. The value of ECAP thresholds to measure C and T values need to be relooked. There was no correlation between the cochlear nerve diameter and the ECAP threshold.","PeriodicalId":14350,"journal":{"name":"International Journal of Otorhinolaryngology and Head and Neck Surgery","volume":"71 4","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrically evoked compound action potential in children following cochlear implantation and its correlation with cochlear nerve diameter\",\"authors\":\"Aparna Das, Arun Alexander, Anuprasad Sreenivasan, Sivaraman Ganesan\",\"doi\":\"10.18203/issn.2454-5929.ijohns20233215\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The study evaluated changes in the threshold of ECAP recorded during cochlear implantation, at switch on, after three months and six months following cochlear implantation. It further assessed the correlation between the ECAP threshold with T and C levels and the cochlear nerve diameter measured preoperatively. Methods: A prospective study of 42 prelingually deaf children who underwent cochlear implantation was conducted. The ECAP threshold values intra-operatively, at switch on, three months and six months were recorded and analysed. The T and C levels were assessed six months postoperatively, and correlation with the ECAP threshold was analysed. The diameter of the cochlear nerve was recorded, and its correlation with the ECAP threshold was determined. Results: Over six months, the basal, central and apical electrodes showed a statistically significant reduction in ECAP threshold of 11.64%, 4.67% and 25.81%, respectively, in candidates implanted with Advanced Bionics implant and 18.89%, 12.78% and 14.08%, respectively in candidates implanted with Nucleus implant. The ECAP thresholds were lower for the apical electrodes. No correlation was found between the ECAP threshold and T and C levels. A correlation between the cochlear nerve diameter and ECAP was not statistically significant. Conclusions: There was a statistically significant change in the ECAP threshold over six months. There was no statistically significant correlation between the ECAP thresholds and T and C levels. The value of ECAP thresholds to measure C and T values need to be relooked. There was no correlation between the cochlear nerve diameter and the ECAP threshold.\",\"PeriodicalId\":14350,\"journal\":{\"name\":\"International Journal of Otorhinolaryngology and Head and Neck Surgery\",\"volume\":\"71 4\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Otorhinolaryngology and Head and Neck Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18203/issn.2454-5929.ijohns20233215\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Otorhinolaryngology and Head and Neck Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18203/issn.2454-5929.ijohns20233215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:本研究评估了人工耳蜗植入期间、开启时、人工耳蜗植入后3个月和6个月ECAP阈值的变化。进一步评估ECAP阈值与术前T、C水平及耳蜗神经直径的相关性。方法:对42例行人工耳蜗植入术的语前聋儿童进行前瞻性研究。记录术中、开机时、3个月和6个月的ECAP阈值并进行分析。术后6个月评估T、C水平,并分析与ECAP阈值的相关性。记录耳蜗神经直径,并测定其与ECAP阈值的相关性。结果:6个月后,Advanced Bionics种植体患者基底电极、中央电极和根尖电极的ECAP阈值分别降低了11.64%、4.67%和25.81%,Nucleus种植体患者ECAP阈值分别降低了18.89%、12.78%和14.08%,具有统计学意义。顶端电极的ECAP阈值较低。ECAP阈值与T、C水平无相关性。耳蜗神经直径与ECAP的相关性无统计学意义。结论:6个月内ECAP阈值有统计学意义的变化。ECAP阈值与T、C水平无统计学意义。测量C和T值的ECAP阈值需要重新审视。耳蜗神经直径与ECAP阈值无相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrically evoked compound action potential in children following cochlear implantation and its correlation with cochlear nerve diameter
Background: The study evaluated changes in the threshold of ECAP recorded during cochlear implantation, at switch on, after three months and six months following cochlear implantation. It further assessed the correlation between the ECAP threshold with T and C levels and the cochlear nerve diameter measured preoperatively. Methods: A prospective study of 42 prelingually deaf children who underwent cochlear implantation was conducted. The ECAP threshold values intra-operatively, at switch on, three months and six months were recorded and analysed. The T and C levels were assessed six months postoperatively, and correlation with the ECAP threshold was analysed. The diameter of the cochlear nerve was recorded, and its correlation with the ECAP threshold was determined. Results: Over six months, the basal, central and apical electrodes showed a statistically significant reduction in ECAP threshold of 11.64%, 4.67% and 25.81%, respectively, in candidates implanted with Advanced Bionics implant and 18.89%, 12.78% and 14.08%, respectively in candidates implanted with Nucleus implant. The ECAP thresholds were lower for the apical electrodes. No correlation was found between the ECAP threshold and T and C levels. A correlation between the cochlear nerve diameter and ECAP was not statistically significant. Conclusions: There was a statistically significant change in the ECAP threshold over six months. There was no statistically significant correlation between the ECAP thresholds and T and C levels. The value of ECAP thresholds to measure C and T values need to be relooked. There was no correlation between the cochlear nerve diameter and the ECAP threshold.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信