{"title":"基于三维图像的股髋臼撞击检测仿真系统的研制","authors":"Chun-Ming Chen, Shang-Chih Lin, Chen-Te Wu, Yi-Sheng Chan","doi":"10.1093/jhps/hnad037","DOIUrl":null,"url":null,"abstract":"ABSTRACT Image-based criteria have been adopted to diagnose femoroacetabular impingement (FAI). However, the overlapping property of the two-dimensional X-ray outlines and static and supine posture of taking computed tomography (CT) and magnetic resonance imaging images potentially affect the accuracy of the criteria. This study developed a CT image–based dynamic criterion to effectively simulate FAI, thereby providing a basis for physicians to perform pre-operative planning for arthroscopic surgery. Post-operative CT images of 20 patients with satisfactory surgical results were collected, and 10 sets of models were used to define the flexion rotation centre (FRC) of the three-dimensional FAI model. First, let these 10 groups of models simulate the FAI detection action and find the best centre offset, and then FRC is the result of averaging these 10 groups of best displacements. The model was validated in 10 additional patients. Finally, through the adjustment basis of FRC, the remaining 10 sets of models can find out the potential position of FAI during the dynamic simulation process. Rotational collisions detected using FRC indicate that the patient’s post-operative flexion angle may reach 120° or greater, which is close to the actual result. The recommended surgical range of the diagnostic system (average length of 6.4 mm, width of 4.1 mm and depth of 3.2 mm) is smaller than the actual surgical results, which prevents the doctor from performing excessive resection operations, which may preserve more bones. The FRC diagnostic system detects the distribution of FAI in a simple manner. It can be used as a pre-operative diagnosis reference for clinicians, hoping to improve the effect and accuracy of debridement surgery.","PeriodicalId":48583,"journal":{"name":"Journal of Hip Preservation Surgery","volume":"4 17","pages":"0"},"PeriodicalIF":1.4000,"publicationDate":"2023-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a simulation system for femoroacetabular impingement detection based on 3D images\",\"authors\":\"Chun-Ming Chen, Shang-Chih Lin, Chen-Te Wu, Yi-Sheng Chan\",\"doi\":\"10.1093/jhps/hnad037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Image-based criteria have been adopted to diagnose femoroacetabular impingement (FAI). However, the overlapping property of the two-dimensional X-ray outlines and static and supine posture of taking computed tomography (CT) and magnetic resonance imaging images potentially affect the accuracy of the criteria. This study developed a CT image–based dynamic criterion to effectively simulate FAI, thereby providing a basis for physicians to perform pre-operative planning for arthroscopic surgery. Post-operative CT images of 20 patients with satisfactory surgical results were collected, and 10 sets of models were used to define the flexion rotation centre (FRC) of the three-dimensional FAI model. First, let these 10 groups of models simulate the FAI detection action and find the best centre offset, and then FRC is the result of averaging these 10 groups of best displacements. The model was validated in 10 additional patients. Finally, through the adjustment basis of FRC, the remaining 10 sets of models can find out the potential position of FAI during the dynamic simulation process. Rotational collisions detected using FRC indicate that the patient’s post-operative flexion angle may reach 120° or greater, which is close to the actual result. The recommended surgical range of the diagnostic system (average length of 6.4 mm, width of 4.1 mm and depth of 3.2 mm) is smaller than the actual surgical results, which prevents the doctor from performing excessive resection operations, which may preserve more bones. The FRC diagnostic system detects the distribution of FAI in a simple manner. It can be used as a pre-operative diagnosis reference for clinicians, hoping to improve the effect and accuracy of debridement surgery.\",\"PeriodicalId\":48583,\"journal\":{\"name\":\"Journal of Hip Preservation Surgery\",\"volume\":\"4 17\",\"pages\":\"0\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hip Preservation Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/jhps/hnad037\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hip Preservation Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jhps/hnad037","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Development of a simulation system for femoroacetabular impingement detection based on 3D images
ABSTRACT Image-based criteria have been adopted to diagnose femoroacetabular impingement (FAI). However, the overlapping property of the two-dimensional X-ray outlines and static and supine posture of taking computed tomography (CT) and magnetic resonance imaging images potentially affect the accuracy of the criteria. This study developed a CT image–based dynamic criterion to effectively simulate FAI, thereby providing a basis for physicians to perform pre-operative planning for arthroscopic surgery. Post-operative CT images of 20 patients with satisfactory surgical results were collected, and 10 sets of models were used to define the flexion rotation centre (FRC) of the three-dimensional FAI model. First, let these 10 groups of models simulate the FAI detection action and find the best centre offset, and then FRC is the result of averaging these 10 groups of best displacements. The model was validated in 10 additional patients. Finally, through the adjustment basis of FRC, the remaining 10 sets of models can find out the potential position of FAI during the dynamic simulation process. Rotational collisions detected using FRC indicate that the patient’s post-operative flexion angle may reach 120° or greater, which is close to the actual result. The recommended surgical range of the diagnostic system (average length of 6.4 mm, width of 4.1 mm and depth of 3.2 mm) is smaller than the actual surgical results, which prevents the doctor from performing excessive resection operations, which may preserve more bones. The FRC diagnostic system detects the distribution of FAI in a simple manner. It can be used as a pre-operative diagnosis reference for clinicians, hoping to improve the effect and accuracy of debridement surgery.