{"title":"基于模拟大信号谱的非线性自热效应分析方法","authors":"J. Aikio, T. Rahkonen","doi":"10.1109/NORCHP.2004.1423830","DOIUrl":null,"url":null,"abstract":"In this paper the harmonic balance is used to simulate the large signal I-V spectra of the intrinsic simulation model that are further used to fit a 3-dimensional electro-thermal polynomial model of the IDS - VDS - VGS nonlinearity. The fitted model is used to analyse the amount of self-heating distortion. To get reliable results a correct model for the thermal circuit of the simulation model is required. Also. strongly correlating control signals cause the system to be difficult to solve. To reliably the IDS different test setups need to be considered.","PeriodicalId":208182,"journal":{"name":"Proceedings Norchip Conference, 2004.","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Analysis method of nonlinear self-heating ef fects based on simulated large signal spectra\",\"authors\":\"J. Aikio, T. Rahkonen\",\"doi\":\"10.1109/NORCHP.2004.1423830\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper the harmonic balance is used to simulate the large signal I-V spectra of the intrinsic simulation model that are further used to fit a 3-dimensional electro-thermal polynomial model of the IDS - VDS - VGS nonlinearity. The fitted model is used to analyse the amount of self-heating distortion. To get reliable results a correct model for the thermal circuit of the simulation model is required. Also. strongly correlating control signals cause the system to be difficult to solve. To reliably the IDS different test setups need to be considered.\",\"PeriodicalId\":208182,\"journal\":{\"name\":\"Proceedings Norchip Conference, 2004.\",\"volume\":\"58 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings Norchip Conference, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NORCHP.2004.1423830\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings Norchip Conference, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NORCHP.2004.1423830","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis method of nonlinear self-heating ef fects based on simulated large signal spectra
In this paper the harmonic balance is used to simulate the large signal I-V spectra of the intrinsic simulation model that are further used to fit a 3-dimensional electro-thermal polynomial model of the IDS - VDS - VGS nonlinearity. The fitted model is used to analyse the amount of self-heating distortion. To get reliable results a correct model for the thermal circuit of the simulation model is required. Also. strongly correlating control signals cause the system to be difficult to solve. To reliably the IDS different test setups need to be considered.