A. Uphues, Kilian Nötzold, R. Griessel, R. Wegener, S. Soter
{"title":"基于逆变器试验台的lvrt能力预评估综述","authors":"A. Uphues, Kilian Nötzold, R. Griessel, R. Wegener, S. Soter","doi":"10.1109/ISIE.2015.7281562","DOIUrl":null,"url":null,"abstract":"With increased renewable power penetration level the system operators of power grids require low-voltage ride-through (LVRT) capability of renewable power plants. The LVRT-capability has to be verified during the process of certification with precisely defined short circuit tests on a reactance based test bench. For the development of the fault ride through (FRT) capability the cost intensive reactance based test configuration is replaced by an inverter based voltage sag generator (VSG). This paper deals with an overview of the whole inverter based test configuration including the control structure of the grid emulator and the adjustment of the grid side converter's control structure to reach LVRT-capability as well as measurement results for the pre-evaluation.","PeriodicalId":377110,"journal":{"name":"2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Overview of LVRT-capability pre-evaluation with an inverter based test bench\",\"authors\":\"A. Uphues, Kilian Nötzold, R. Griessel, R. Wegener, S. Soter\",\"doi\":\"10.1109/ISIE.2015.7281562\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With increased renewable power penetration level the system operators of power grids require low-voltage ride-through (LVRT) capability of renewable power plants. The LVRT-capability has to be verified during the process of certification with precisely defined short circuit tests on a reactance based test bench. For the development of the fault ride through (FRT) capability the cost intensive reactance based test configuration is replaced by an inverter based voltage sag generator (VSG). This paper deals with an overview of the whole inverter based test configuration including the control structure of the grid emulator and the adjustment of the grid side converter's control structure to reach LVRT-capability as well as measurement results for the pre-evaluation.\",\"PeriodicalId\":377110,\"journal\":{\"name\":\"2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2015.7281562\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2015.7281562","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Overview of LVRT-capability pre-evaluation with an inverter based test bench
With increased renewable power penetration level the system operators of power grids require low-voltage ride-through (LVRT) capability of renewable power plants. The LVRT-capability has to be verified during the process of certification with precisely defined short circuit tests on a reactance based test bench. For the development of the fault ride through (FRT) capability the cost intensive reactance based test configuration is replaced by an inverter based voltage sag generator (VSG). This paper deals with an overview of the whole inverter based test configuration including the control structure of the grid emulator and the adjustment of the grid side converter's control structure to reach LVRT-capability as well as measurement results for the pre-evaluation.