{"title":"不及时拼接节省9个:事后的完整性检查","authors":"Racin Gudmestad, S. Houmb, M. Jaatun","doi":"10.1109/SA51175.2021.9507115","DOIUrl":null,"url":null,"abstract":"Electrical substations transform voltage from high to low, or low to high for distribution and transmission, respectively, and are a critical part of our electricity infrastructure. The state of a substation is continuously measured for monitoring, controlling and protection purposes, using synchrophasor measurements. The IEC 61850 standard defines communication protocols for electrical substations, including transmission of synchrophasor measurements. However, IEC 61850 does not properly address cyber security, leaving this critical infrastructure highly vulnerable to cyber attacks. This paper describes the development and testing of a novel mechanism for delayed integrity check for synchrophasor measurements. The results show that the solution manages to detect when integrity of the synchrophasor transmission is compromised, without adding any delay to the time-critical synchrophasor transmission itself.","PeriodicalId":117020,"journal":{"name":"2020 2nd International Conference on Societal Automation (SA)","volume":"127 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Saving Nine Without Stitching in Time: Integrity Check After-the-fact\",\"authors\":\"Racin Gudmestad, S. Houmb, M. Jaatun\",\"doi\":\"10.1109/SA51175.2021.9507115\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrical substations transform voltage from high to low, or low to high for distribution and transmission, respectively, and are a critical part of our electricity infrastructure. The state of a substation is continuously measured for monitoring, controlling and protection purposes, using synchrophasor measurements. The IEC 61850 standard defines communication protocols for electrical substations, including transmission of synchrophasor measurements. However, IEC 61850 does not properly address cyber security, leaving this critical infrastructure highly vulnerable to cyber attacks. This paper describes the development and testing of a novel mechanism for delayed integrity check for synchrophasor measurements. The results show that the solution manages to detect when integrity of the synchrophasor transmission is compromised, without adding any delay to the time-critical synchrophasor transmission itself.\",\"PeriodicalId\":117020,\"journal\":{\"name\":\"2020 2nd International Conference on Societal Automation (SA)\",\"volume\":\"127 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 2nd International Conference on Societal Automation (SA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SA51175.2021.9507115\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 2nd International Conference on Societal Automation (SA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SA51175.2021.9507115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

变电站将电压由高到低、由低到高分别用于配电和输电,是我国电力基础设施的重要组成部分。为了监测、控制和保护的目的,使用同步相量测量对变电站的状态进行连续测量。IEC 61850标准定义了变电站的通信协议,包括同步量测量的传输。然而,IEC 61850并没有正确解决网络安全问题,使这一关键基础设施极易受到网络攻击。本文描述了一种用于同步量测量的延迟完整性检查的新机制的开发和测试。结果表明,该解决方案设法检测同步相量传输的完整性何时受到损害,而不会给时间关键同步相量传输本身增加任何延迟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Saving Nine Without Stitching in Time: Integrity Check After-the-fact
Electrical substations transform voltage from high to low, or low to high for distribution and transmission, respectively, and are a critical part of our electricity infrastructure. The state of a substation is continuously measured for monitoring, controlling and protection purposes, using synchrophasor measurements. The IEC 61850 standard defines communication protocols for electrical substations, including transmission of synchrophasor measurements. However, IEC 61850 does not properly address cyber security, leaving this critical infrastructure highly vulnerable to cyber attacks. This paper describes the development and testing of a novel mechanism for delayed integrity check for synchrophasor measurements. The results show that the solution manages to detect when integrity of the synchrophasor transmission is compromised, without adding any delay to the time-critical synchrophasor transmission itself.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信