检测各种电力盗窃的控制器设计

S. Venkateswarlu, Divya Teja Ankireddy, N. Kumar, Rathaiah Meram, T. Prakash, Jarapala Siva Naik
{"title":"检测各种电力盗窃的控制器设计","authors":"S. Venkateswarlu, Divya Teja Ankireddy, N. Kumar, Rathaiah Meram, T. Prakash, Jarapala Siva Naik","doi":"10.1109/i-PACT52855.2021.9696752","DOIUrl":null,"url":null,"abstract":"Power theft is the serious unlawful methods in developing countries like India in order to avoid electricity charges. It is a major problem in every country and it must be avoided. So it is necessary to propose a system which can able to monitor the power theft and also location of theft occur. The proposed system must take required action during theft conditions. This paper describes the reliable approach to detect the power theft and to clear the fault in distribution lines. The developed control scheme require the readings of current and voltage values of house hold energy meter and transformer of distribution side. From the control design, if there is any voltage drop in load side because of power theft, the system automatically detects the power theft and locates the distance from the distribution line. So the circuit breaker got a signal from the controller simultaneously. The breaker blocks the electricity and it rechecks four times to remove the theft. In the paper, the theft is created artificially under various loads. Three different power thefts like R, RL and RLC are taken at three different tapping and percentage error is calculated from output and presented in tabular column. The proposed scheme is done in MATLAB/Simulink environment.","PeriodicalId":335956,"journal":{"name":"2021 Innovations in Power and Advanced Computing Technologies (i-PACT)","volume":"64 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Controller Design For Detection of Various Power Thefts\",\"authors\":\"S. Venkateswarlu, Divya Teja Ankireddy, N. Kumar, Rathaiah Meram, T. Prakash, Jarapala Siva Naik\",\"doi\":\"10.1109/i-PACT52855.2021.9696752\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power theft is the serious unlawful methods in developing countries like India in order to avoid electricity charges. It is a major problem in every country and it must be avoided. So it is necessary to propose a system which can able to monitor the power theft and also location of theft occur. The proposed system must take required action during theft conditions. This paper describes the reliable approach to detect the power theft and to clear the fault in distribution lines. The developed control scheme require the readings of current and voltage values of house hold energy meter and transformer of distribution side. From the control design, if there is any voltage drop in load side because of power theft, the system automatically detects the power theft and locates the distance from the distribution line. So the circuit breaker got a signal from the controller simultaneously. The breaker blocks the electricity and it rechecks four times to remove the theft. In the paper, the theft is created artificially under various loads. Three different power thefts like R, RL and RLC are taken at three different tapping and percentage error is calculated from output and presented in tabular column. The proposed scheme is done in MATLAB/Simulink environment.\",\"PeriodicalId\":335956,\"journal\":{\"name\":\"2021 Innovations in Power and Advanced Computing Technologies (i-PACT)\",\"volume\":\"64 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 Innovations in Power and Advanced Computing Technologies (i-PACT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/i-PACT52855.2021.9696752\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Innovations in Power and Advanced Computing Technologies (i-PACT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/i-PACT52855.2021.9696752","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

窃电是印度等发展中国家为逃避电费而采取的严重非法手段。这是每个国家的一个大问题,必须加以避免。因此,有必要设计一种既能监控窃电又能定位窃电发生位置的系统。建议的系统必须在盗窃情况下采取必要的行动。本文介绍了一种可靠的配电线路窃电检测和故障清除方法。所制定的控制方案需要户用电能表和配电侧变压器的电流、电压读数。从控制设计上看,如果负载侧因盗电而出现电压下降,系统会自动检测到盗电,并定位到离配电线路的距离。这样断路器就同时得到了控制器的信号。断路器切断电源,并重新检查四次以消除盗窃。在本文中,盗窃是在各种负载下人为制造的。三种不同的功率盗窃,如R, RL和RLC,在三种不同的攻丝下进行,并从输出中计算百分比误差,并以表格列形式呈现。该方案是在MATLAB/Simulink环境下完成的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Controller Design For Detection of Various Power Thefts
Power theft is the serious unlawful methods in developing countries like India in order to avoid electricity charges. It is a major problem in every country and it must be avoided. So it is necessary to propose a system which can able to monitor the power theft and also location of theft occur. The proposed system must take required action during theft conditions. This paper describes the reliable approach to detect the power theft and to clear the fault in distribution lines. The developed control scheme require the readings of current and voltage values of house hold energy meter and transformer of distribution side. From the control design, if there is any voltage drop in load side because of power theft, the system automatically detects the power theft and locates the distance from the distribution line. So the circuit breaker got a signal from the controller simultaneously. The breaker blocks the electricity and it rechecks four times to remove the theft. In the paper, the theft is created artificially under various loads. Three different power thefts like R, RL and RLC are taken at three different tapping and percentage error is calculated from output and presented in tabular column. The proposed scheme is done in MATLAB/Simulink environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信