心室形状变化对逆心电图的影响:一项可行性研究

A. Rahimi, Linwei Wang
{"title":"心室形状变化对逆心电图的影响:一项可行性研究","authors":"A. Rahimi, Linwei Wang","doi":"10.1109/ISBI.2013.6556537","DOIUrl":null,"url":null,"abstract":"Inverse electrocardiography (IECG) estimates cardiac electrical dynamics from body surface electrocardiographic data. As a common practice, all existing IECG problems are solved on anatomically-detailed heart and torso models derived from tomographic images of individual subjects. This practice constitutes a major obstacle to clinical translation of IECG methods, imposing high demands on the quality and processing of medical images. Because anatomical modeling is always associated with variations due to different factors such as image quality and segmentation methods, we design a novel and systematic approach to statistically quantify the impact of ventricular shape variations on the diagnostic accuracy of IECG methods. We propose a novel use of statistical shape modeling to account for the variations in subject-specific anatomical modeling, and from it to generate ventricular models with controlled variations, whose relation to the variations of IECG outputs are then statistically assessed. In this study, we test the feasibility of the proposed approach considering two existing IECG methods for epicardial potential reconstruction and transmural action potential imaging. Both phantom and real-data experiments report statistical equivalency of IECG diagnostic accuracy on ventricular models with local variations. This study demonstrates the feasibility of the proposed approach to be generalized to establish the proper level of anatomical details needed in ventricular modeling, which has the potential to change the common practice and facilitate the clinical translation of IECG research.","PeriodicalId":178011,"journal":{"name":"2013 IEEE 10th International Symposium on Biomedical Imaging","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The impact of ventricular shape variations on inverse electrocardiography: A feasibility study\",\"authors\":\"A. Rahimi, Linwei Wang\",\"doi\":\"10.1109/ISBI.2013.6556537\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inverse electrocardiography (IECG) estimates cardiac electrical dynamics from body surface electrocardiographic data. As a common practice, all existing IECG problems are solved on anatomically-detailed heart and torso models derived from tomographic images of individual subjects. This practice constitutes a major obstacle to clinical translation of IECG methods, imposing high demands on the quality and processing of medical images. Because anatomical modeling is always associated with variations due to different factors such as image quality and segmentation methods, we design a novel and systematic approach to statistically quantify the impact of ventricular shape variations on the diagnostic accuracy of IECG methods. We propose a novel use of statistical shape modeling to account for the variations in subject-specific anatomical modeling, and from it to generate ventricular models with controlled variations, whose relation to the variations of IECG outputs are then statistically assessed. In this study, we test the feasibility of the proposed approach considering two existing IECG methods for epicardial potential reconstruction and transmural action potential imaging. Both phantom and real-data experiments report statistical equivalency of IECG diagnostic accuracy on ventricular models with local variations. This study demonstrates the feasibility of the proposed approach to be generalized to establish the proper level of anatomical details needed in ventricular modeling, which has the potential to change the common practice and facilitate the clinical translation of IECG research.\",\"PeriodicalId\":178011,\"journal\":{\"name\":\"2013 IEEE 10th International Symposium on Biomedical Imaging\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE 10th International Symposium on Biomedical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBI.2013.6556537\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 10th International Symposium on Biomedical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI.2013.6556537","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

逆心电图(IECG)从体表心电图数据估计心电动力学。作为一种常见的做法,所有现有的IECG问题都是在个体受试者的断层成像图像中得到的解剖细节的心脏和躯干模型上解决的。这种做法构成了IECG方法临床翻译的主要障碍,对医学图像的质量和处理提出了很高的要求。由于解剖建模总是与图像质量和分割方法等不同因素引起的变化有关,因此我们设计了一种新颖而系统的方法来统计量化心室形状变化对IECG方法诊断准确性的影响。我们提出了一种新的统计形状建模方法来解释受试者特定解剖模型的变化,并由此产生具有控制变化的心室模型,然后对其与IECG输出变化的关系进行统计评估。在这项研究中,我们结合两种现有的心外膜电位重建和跨壁动作电位成像的IECG方法来测试所提出方法的可行性。模拟实验和实际数据实验都报告了IECG对局部变异心室模型诊断准确性的统计等效性。本研究证明了该方法的可行性,可以推广到建立心室建模所需的适当解剖细节水平,这有可能改变常规做法,促进IECG研究的临床转化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The impact of ventricular shape variations on inverse electrocardiography: A feasibility study
Inverse electrocardiography (IECG) estimates cardiac electrical dynamics from body surface electrocardiographic data. As a common practice, all existing IECG problems are solved on anatomically-detailed heart and torso models derived from tomographic images of individual subjects. This practice constitutes a major obstacle to clinical translation of IECG methods, imposing high demands on the quality and processing of medical images. Because anatomical modeling is always associated with variations due to different factors such as image quality and segmentation methods, we design a novel and systematic approach to statistically quantify the impact of ventricular shape variations on the diagnostic accuracy of IECG methods. We propose a novel use of statistical shape modeling to account for the variations in subject-specific anatomical modeling, and from it to generate ventricular models with controlled variations, whose relation to the variations of IECG outputs are then statistically assessed. In this study, we test the feasibility of the proposed approach considering two existing IECG methods for epicardial potential reconstruction and transmural action potential imaging. Both phantom and real-data experiments report statistical equivalency of IECG diagnostic accuracy on ventricular models with local variations. This study demonstrates the feasibility of the proposed approach to be generalized to establish the proper level of anatomical details needed in ventricular modeling, which has the potential to change the common practice and facilitate the clinical translation of IECG research.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信