医疗器械计算机辅助临床试验的高级建模

Houssam Abbas, Zhihao Jiang, Kuk Jin Jang, M. Beccani, J. Liang, R. Mangharam
{"title":"医疗器械计算机辅助临床试验的高级建模","authors":"Houssam Abbas, Zhihao Jiang, Kuk Jin Jang, M. Beccani, J. Liang, R. Mangharam","doi":"10.1109/HLDVT.2016.7748260","DOIUrl":null,"url":null,"abstract":"Medical devices like the Implantable Cardioverter Defibrillator (ICD) are life-critical systems. Malfunctions of the device can cause serious injury or death of the patient. In addition to rigorous testing and verification during the development process, new medical devices often go through clinical trials to evaluate their safety and performance on sample populations. Clinical trials are costly and prone to failure if not planned and executed properly. Evaluating devices on computer models of the relevant physiological systems can provide helpful insights into the safety and efficacy of the device, thus helping to plan and execute a clinical trial. In this paper, we demonstrate how to develop high-level physiological models of cardiac electrophysiology and how to apply them to the Rhythm ID Head to Head Trial (RIGHT), a 5-year long clinical trial for comparing two ICDs. We refer to this as a Computer-Aided Clinical Trial (CACT). We explored two modeling options, a white-box model capturing the mechanisms of the physiological behaviors, and a blackbox model which uses machine learning methods to synthesize physiological input signals. Both models were able to generate physiological inputs to the ICDs and we discuss the challenges and appropriateness of the two modeling options.","PeriodicalId":166427,"journal":{"name":"2016 IEEE International High Level Design Validation and Test Workshop (HLDVT)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"High-level modeling for computer-aided clinical trials of medical devices\",\"authors\":\"Houssam Abbas, Zhihao Jiang, Kuk Jin Jang, M. Beccani, J. Liang, R. Mangharam\",\"doi\":\"10.1109/HLDVT.2016.7748260\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Medical devices like the Implantable Cardioverter Defibrillator (ICD) are life-critical systems. Malfunctions of the device can cause serious injury or death of the patient. In addition to rigorous testing and verification during the development process, new medical devices often go through clinical trials to evaluate their safety and performance on sample populations. Clinical trials are costly and prone to failure if not planned and executed properly. Evaluating devices on computer models of the relevant physiological systems can provide helpful insights into the safety and efficacy of the device, thus helping to plan and execute a clinical trial. In this paper, we demonstrate how to develop high-level physiological models of cardiac electrophysiology and how to apply them to the Rhythm ID Head to Head Trial (RIGHT), a 5-year long clinical trial for comparing two ICDs. We refer to this as a Computer-Aided Clinical Trial (CACT). We explored two modeling options, a white-box model capturing the mechanisms of the physiological behaviors, and a blackbox model which uses machine learning methods to synthesize physiological input signals. Both models were able to generate physiological inputs to the ICDs and we discuss the challenges and appropriateness of the two modeling options.\",\"PeriodicalId\":166427,\"journal\":{\"name\":\"2016 IEEE International High Level Design Validation and Test Workshop (HLDVT)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International High Level Design Validation and Test Workshop (HLDVT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HLDVT.2016.7748260\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International High Level Design Validation and Test Workshop (HLDVT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HLDVT.2016.7748260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

像植入式心律转复除颤器(ICD)这样的医疗设备是危及生命的系统。设备的故障可能导致患者严重受伤甚至死亡。除了在开发过程中进行严格的测试和验证外,新的医疗设备通常还要经过临床试验,以评估其在样本人群中的安全性和性能。如果计划和执行不当,临床试验成本高昂,而且容易失败。在相关生理系统的计算机模型上评估设备可以为设备的安全性和有效性提供有用的见解,从而有助于计划和执行临床试验。在本文中,我们展示了如何开发心脏电生理的高级生理模型,以及如何将它们应用于心律ID头对头试验(右),这是一项为期5年的比较两种icd的临床试验。我们称之为计算机辅助临床试验(CACT)。我们探索了两种建模选项,一种是捕获生理行为机制的白盒模型,另一种是使用机器学习方法合成生理输入信号的黑盒模型。这两种模型都能够产生icd的生理输入,我们讨论了这两种建模选项的挑战和适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High-level modeling for computer-aided clinical trials of medical devices
Medical devices like the Implantable Cardioverter Defibrillator (ICD) are life-critical systems. Malfunctions of the device can cause serious injury or death of the patient. In addition to rigorous testing and verification during the development process, new medical devices often go through clinical trials to evaluate their safety and performance on sample populations. Clinical trials are costly and prone to failure if not planned and executed properly. Evaluating devices on computer models of the relevant physiological systems can provide helpful insights into the safety and efficacy of the device, thus helping to plan and execute a clinical trial. In this paper, we demonstrate how to develop high-level physiological models of cardiac electrophysiology and how to apply them to the Rhythm ID Head to Head Trial (RIGHT), a 5-year long clinical trial for comparing two ICDs. We refer to this as a Computer-Aided Clinical Trial (CACT). We explored two modeling options, a white-box model capturing the mechanisms of the physiological behaviors, and a blackbox model which uses machine learning methods to synthesize physiological input signals. Both models were able to generate physiological inputs to the ICDs and we discuss the challenges and appropriateness of the two modeling options.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信