对改进功率因数校正有新的贡献

I. Kasikei, M. Darwish, P. Mehta
{"title":"对改进功率因数校正有新的贡献","authors":"I. Kasikei, M. Darwish, P. Mehta","doi":"10.1109/DRPT.2000.855646","DOIUrl":null,"url":null,"abstract":"This paper presents an improved new method for power factor correction and harmonic current reduction using IGBTs and a passive filter which is suitable to compensate rapidly changing loads and reactive power. Furthermore, a single-phase control concept is discussed for simplicity. The results can be implemented in three-phase systems without any problems. It also presents a brief discussion of the main problems in the distribution power systems. The increased use of nonlinear devices cause voltage distortion in the network. This leads to malfunctions of the electric facilities and to costly interruptions of production. The filter circuit parameters are analysed and described. This filter configuration provides an alternative approach to the existing one. According to the test results, the proposed approach can achieve a complete elimination of harmonics.","PeriodicalId":127287,"journal":{"name":"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"A new contribution into the improvement of power factor correction\",\"authors\":\"I. Kasikei, M. Darwish, P. Mehta\",\"doi\":\"10.1109/DRPT.2000.855646\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an improved new method for power factor correction and harmonic current reduction using IGBTs and a passive filter which is suitable to compensate rapidly changing loads and reactive power. Furthermore, a single-phase control concept is discussed for simplicity. The results can be implemented in three-phase systems without any problems. It also presents a brief discussion of the main problems in the distribution power systems. The increased use of nonlinear devices cause voltage distortion in the network. This leads to malfunctions of the electric facilities and to costly interruptions of production. The filter circuit parameters are analysed and described. This filter configuration provides an alternative approach to the existing one. According to the test results, the proposed approach can achieve a complete elimination of harmonics.\",\"PeriodicalId\":127287,\"journal\":{\"name\":\"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)\",\"volume\":\"96 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DRPT.2000.855646\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DRPT2000. International Conference on Electric Utility Deregulation and Restructuring and Power Technologies. Proceedings (Cat. No.00EX382)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DRPT.2000.855646","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文提出了一种利用igbt和无源滤波器进行功率因数校正和谐波电流减小的改进新方法,适用于补偿快速变化的负载和无功功率。此外,为了简单起见,还讨论了单相控制的概念。结果可以在三相系统中实现,没有任何问题。并对配电系统中存在的主要问题作了简要的讨论。非线性器件使用的增加会引起网络中的电压畸变。这将导致电力设施的故障和昂贵的生产中断。对滤波电路参数进行了分析和描述。此过滤器配置提供了现有过滤器的替代方法。测试结果表明,该方法可以完全消除谐波。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new contribution into the improvement of power factor correction
This paper presents an improved new method for power factor correction and harmonic current reduction using IGBTs and a passive filter which is suitable to compensate rapidly changing loads and reactive power. Furthermore, a single-phase control concept is discussed for simplicity. The results can be implemented in three-phase systems without any problems. It also presents a brief discussion of the main problems in the distribution power systems. The increased use of nonlinear devices cause voltage distortion in the network. This leads to malfunctions of the electric facilities and to costly interruptions of production. The filter circuit parameters are analysed and described. This filter configuration provides an alternative approach to the existing one. According to the test results, the proposed approach can achieve a complete elimination of harmonics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信