{"title":"同轴式热电发电机的仿真与计算","authors":"V. Loboda, R. Buslaev","doi":"10.1109/ISFEE51261.2020.9756152","DOIUrl":null,"url":null,"abstract":"The paper deals with the simulation and the calculation of output parameters for coaxial and ordinary thermoelectric generators with cylindrical and rectangular thermoelement geometry. It is shown that the thermoelements geometry does not affect the output power. The differences between output parameters of coaxial and ordinary thermoelectric generators are not significant. The calculation has been done by finite element method using ANSYS.","PeriodicalId":145923,"journal":{"name":"2020 International Symposium on Fundamentals of Electrical Engineering (ISFEE)","volume":"134 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Coaxial Type Thermoelectric Generator Simulation and Calculation\",\"authors\":\"V. Loboda, R. Buslaev\",\"doi\":\"10.1109/ISFEE51261.2020.9756152\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper deals with the simulation and the calculation of output parameters for coaxial and ordinary thermoelectric generators with cylindrical and rectangular thermoelement geometry. It is shown that the thermoelements geometry does not affect the output power. The differences between output parameters of coaxial and ordinary thermoelectric generators are not significant. The calculation has been done by finite element method using ANSYS.\",\"PeriodicalId\":145923,\"journal\":{\"name\":\"2020 International Symposium on Fundamentals of Electrical Engineering (ISFEE)\",\"volume\":\"134 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 International Symposium on Fundamentals of Electrical Engineering (ISFEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISFEE51261.2020.9756152\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Symposium on Fundamentals of Electrical Engineering (ISFEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISFEE51261.2020.9756152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Coaxial Type Thermoelectric Generator Simulation and Calculation
The paper deals with the simulation and the calculation of output parameters for coaxial and ordinary thermoelectric generators with cylindrical and rectangular thermoelement geometry. It is shown that the thermoelements geometry does not affect the output power. The differences between output parameters of coaxial and ordinary thermoelectric generators are not significant. The calculation has been done by finite element method using ANSYS.