P300-BCI鲁棒视觉刺激器

Indar Sugiarto
{"title":"P300-BCI鲁棒视觉刺激器","authors":"Indar Sugiarto","doi":"10.1109/ICICI-BME.2009.5417236","DOIUrl":null,"url":null,"abstract":"A method of displaying robust visual stimulator for P300-BCI is proposed. This visual stimulator plays vital role in BCI system since the evoked potential with duration of 300ms is mainly affected by the precise timing of each trial. It is preferable that the number of trials must be set as small as possible and it means that the stimulator which provides the random stimuli must operate in the very exact time. There are three main factors which contribute to the robustness of P300 visual stimulator in this paper: accurate timing provided by the high resolution system timer, video graphic display technology (i.e. OpenGL in this paper), and process/thread priority management. From the measurement, it can be seen that the timing function which is provided through a dedicated thread, has a very high accuracy with signal delay less than 300µs. All of programs written in this paper were developed using Open Source software tools. It is developed with two kind of patterns: letter matrix and icon matrix. It also contains two stimulation method: random block of row/column and random cells, by which it may increase cell's uncertainty and finally enhance P300 amplitude.","PeriodicalId":191194,"journal":{"name":"International Conference on Instrumentation, Communication, Information Technology, and Biomedical Engineering 2009","volume":"493 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Robust visual stimulator for P300-BCI\",\"authors\":\"Indar Sugiarto\",\"doi\":\"10.1109/ICICI-BME.2009.5417236\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method of displaying robust visual stimulator for P300-BCI is proposed. This visual stimulator plays vital role in BCI system since the evoked potential with duration of 300ms is mainly affected by the precise timing of each trial. It is preferable that the number of trials must be set as small as possible and it means that the stimulator which provides the random stimuli must operate in the very exact time. There are three main factors which contribute to the robustness of P300 visual stimulator in this paper: accurate timing provided by the high resolution system timer, video graphic display technology (i.e. OpenGL in this paper), and process/thread priority management. From the measurement, it can be seen that the timing function which is provided through a dedicated thread, has a very high accuracy with signal delay less than 300µs. All of programs written in this paper were developed using Open Source software tools. It is developed with two kind of patterns: letter matrix and icon matrix. It also contains two stimulation method: random block of row/column and random cells, by which it may increase cell's uncertainty and finally enhance P300 amplitude.\",\"PeriodicalId\":191194,\"journal\":{\"name\":\"International Conference on Instrumentation, Communication, Information Technology, and Biomedical Engineering 2009\",\"volume\":\"493 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Conference on Instrumentation, Communication, Information Technology, and Biomedical Engineering 2009\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICICI-BME.2009.5417236\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Instrumentation, Communication, Information Technology, and Biomedical Engineering 2009","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICI-BME.2009.5417236","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种用于P300-BCI的鲁棒视觉刺激器显示方法。这种视觉刺激在脑机接口系统中起着至关重要的作用,因为300ms的诱发电位主要受每次试验的精确时间的影响。最好将试验次数设置得尽可能小,这意味着提供随机刺激的刺激器必须在非常精确的时间内运行。本文中P300视觉刺激器的鲁棒性主要有三个因素:高分辨率系统计时器提供的精确定时、视频图形显示技术(即本文中的OpenGL)以及进程/线程优先级管理。从测量中可以看出,通过专用线程提供的定时功能具有非常高的精度,信号延迟小于300µs。本文编写的所有程序都是使用开源软件工具开发的。它有两种开发模式:字母矩阵和图标矩阵。它还包含行/列随机块和随机细胞两种刺激方式,可以增加细胞的不确定性,最终增强P300振幅。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Robust visual stimulator for P300-BCI
A method of displaying robust visual stimulator for P300-BCI is proposed. This visual stimulator plays vital role in BCI system since the evoked potential with duration of 300ms is mainly affected by the precise timing of each trial. It is preferable that the number of trials must be set as small as possible and it means that the stimulator which provides the random stimuli must operate in the very exact time. There are three main factors which contribute to the robustness of P300 visual stimulator in this paper: accurate timing provided by the high resolution system timer, video graphic display technology (i.e. OpenGL in this paper), and process/thread priority management. From the measurement, it can be seen that the timing function which is provided through a dedicated thread, has a very high accuracy with signal delay less than 300µs. All of programs written in this paper were developed using Open Source software tools. It is developed with two kind of patterns: letter matrix and icon matrix. It also contains two stimulation method: random block of row/column and random cells, by which it may increase cell's uncertainty and finally enhance P300 amplitude.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信