充电、馈电和测试电缆长度对R/sup 2/SPG波形的影响

L. Hoeft, R.J. Karaskiewicz, J. Hofstra, W. Prather, W. R. Ayres
{"title":"充电、馈电和测试电缆长度对R/sup 2/SPG波形的影响","authors":"L. Hoeft, R.J. Karaskiewicz, J. Hofstra, W. Prather, W. R. Ayres","doi":"10.1109/ISEMC.1991.148176","DOIUrl":null,"url":null,"abstract":"The random repetitive squarewave pulse generator (R/sup 2/SPG) was developed for in situ upset testing of cable connected equipment. This pulser uses a charge line and a vacuum switch to produce a broadband transient that approximates a damped squarewave with a risetime of the order of a few nanoseconds, determined by the impedance discontinuities of the switch, and a ringing frequency that is related to the electrical length of the charge and feed lines. In order to better understand the relationships between the lengths of the charge, feed, and test cables, a controlled experiment was performed that varied each of these independently. The currents induced on the test cable were consistent with a simple transmission line model. The ringing frequency of the pulser, determined by the electrical length of the charge and feed lines, was generally discernible, as was the resonant frequency of the test cable. The peak amplitude of the transient and the decay rate of the pulse spectrum were unaffected by changes in the charge and feed lines.<<ETX>>","PeriodicalId":243730,"journal":{"name":"IEEE 1991 International Symposium on Electromagnetic Compatibility","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Effect of charge, feed, and test cable lengths on R/sup 2/SPG waveforms\",\"authors\":\"L. Hoeft, R.J. Karaskiewicz, J. Hofstra, W. Prather, W. R. Ayres\",\"doi\":\"10.1109/ISEMC.1991.148176\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The random repetitive squarewave pulse generator (R/sup 2/SPG) was developed for in situ upset testing of cable connected equipment. This pulser uses a charge line and a vacuum switch to produce a broadband transient that approximates a damped squarewave with a risetime of the order of a few nanoseconds, determined by the impedance discontinuities of the switch, and a ringing frequency that is related to the electrical length of the charge and feed lines. In order to better understand the relationships between the lengths of the charge, feed, and test cables, a controlled experiment was performed that varied each of these independently. The currents induced on the test cable were consistent with a simple transmission line model. The ringing frequency of the pulser, determined by the electrical length of the charge and feed lines, was generally discernible, as was the resonant frequency of the test cable. The peak amplitude of the transient and the decay rate of the pulse spectrum were unaffected by changes in the charge and feed lines.<<ETX>>\",\"PeriodicalId\":243730,\"journal\":{\"name\":\"IEEE 1991 International Symposium on Electromagnetic Compatibility\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE 1991 International Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.1991.148176\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1991 International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1991.148176","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

研制了随机重复方波脉冲发生器(R/sup 2/SPG),用于电缆连接设备的现场扰动试验。该脉冲发生器使用电荷线和真空开关产生宽带瞬态,其近似于衰减方波,其上升时间为几纳秒,由开关的阻抗不连续决定,而振铃频率与电荷线和馈电线的电长度有关。为了更好地了解充电电缆、馈电电缆和测试电缆长度之间的关系,进行了一项对照实验,分别改变了这些电缆的长度。试验电缆上感应电流与简单传输线模型一致。脉冲发生器的振铃频率,由充电线和馈线的电气长度决定,通常是可识别的,测试电缆的谐振频率也是如此。瞬态峰幅和脉冲谱衰减速率不受电荷线和馈电线变化的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of charge, feed, and test cable lengths on R/sup 2/SPG waveforms
The random repetitive squarewave pulse generator (R/sup 2/SPG) was developed for in situ upset testing of cable connected equipment. This pulser uses a charge line and a vacuum switch to produce a broadband transient that approximates a damped squarewave with a risetime of the order of a few nanoseconds, determined by the impedance discontinuities of the switch, and a ringing frequency that is related to the electrical length of the charge and feed lines. In order to better understand the relationships between the lengths of the charge, feed, and test cables, a controlled experiment was performed that varied each of these independently. The currents induced on the test cable were consistent with a simple transmission line model. The ringing frequency of the pulser, determined by the electrical length of the charge and feed lines, was generally discernible, as was the resonant frequency of the test cable. The peak amplitude of the transient and the decay rate of the pulse spectrum were unaffected by changes in the charge and feed lines.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信