利用输电线路监测系统测量天气参数进行负荷预测

R. Holmukhe, P. S. Chaudhari, P. Kulkarni, Kiran Deshpande, P. Kulkarni
{"title":"利用输电线路监测系统测量天气参数进行负荷预测","authors":"R. Holmukhe, P. S. Chaudhari, P. Kulkarni, Kiran Deshpande, P. Kulkarni","doi":"10.1109/ICETET.2010.155","DOIUrl":null,"url":null,"abstract":"Climate has significant impact on generation, transmission and demand of electricity. There is need to manage weather and climate effects to avoid penalties due to incorrectly predicted demand. The effect of weather changes is seen through fluctuation of electricity demand. Electricity demand is influenced by temperature, wind speed, humidity, precipitation and cloud cover. This further effects practically demand for air condidtioning, space heating, refrigeration and water pumping loads. This changes the peak demand and 24 hour demand. Transmission systems are found to be sensitive through thermal constraints and faults caused by extreme weather conditions. Demand levels are also weather sensitive. Thus all these pose serious challenges to electicity supply industry. It is also true that the forecasted load by load forecasters at load dispatch center, depend on the reliability of line that weather it is conveying that much of MW share to all related areas. Transmission system should be protected from weather effects. So proper means like some type of devices should be equipped over the tower which should sense the weather factors like temperature, humidity etc in prior. This paper presents the device named transmission line monitoring system for the measurement of weather parameters.","PeriodicalId":175615,"journal":{"name":"2010 3rd International Conference on Emerging Trends in Engineering and Technology","volume":"71 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Measurement of Weather Parameters via Transmission Line Monitoring System for Load Forecasting\",\"authors\":\"R. Holmukhe, P. S. Chaudhari, P. Kulkarni, Kiran Deshpande, P. Kulkarni\",\"doi\":\"10.1109/ICETET.2010.155\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Climate has significant impact on generation, transmission and demand of electricity. There is need to manage weather and climate effects to avoid penalties due to incorrectly predicted demand. The effect of weather changes is seen through fluctuation of electricity demand. Electricity demand is influenced by temperature, wind speed, humidity, precipitation and cloud cover. This further effects practically demand for air condidtioning, space heating, refrigeration and water pumping loads. This changes the peak demand and 24 hour demand. Transmission systems are found to be sensitive through thermal constraints and faults caused by extreme weather conditions. Demand levels are also weather sensitive. Thus all these pose serious challenges to electicity supply industry. It is also true that the forecasted load by load forecasters at load dispatch center, depend on the reliability of line that weather it is conveying that much of MW share to all related areas. Transmission system should be protected from weather effects. So proper means like some type of devices should be equipped over the tower which should sense the weather factors like temperature, humidity etc in prior. This paper presents the device named transmission line monitoring system for the measurement of weather parameters.\",\"PeriodicalId\":175615,\"journal\":{\"name\":\"2010 3rd International Conference on Emerging Trends in Engineering and Technology\",\"volume\":\"71 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 3rd International Conference on Emerging Trends in Engineering and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICETET.2010.155\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 3rd International Conference on Emerging Trends in Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICETET.2010.155","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

气候对发电、输电和电力需求有重大影响。有必要管理天气和气候影响,以避免因错误预测需求而受到惩罚。天气变化的影响是通过电力需求的波动来体现的。电力需求受温度、风速、湿度、降水和云量的影响。这进一步影响了对空调、空间供暖、制冷和抽水负荷的实际需求。这改变了高峰需求和24小时需求。通过热约束和极端天气条件引起的故障,发现输电系统是敏感的。需求水平对天气也很敏感。这些都给供电行业带来了严峻的挑战。负荷调度中心的负荷预报员对负荷的预测也取决于线路的可靠性,即线路是否向所有相关地区输送了那么多MW份额。传输系统应不受天气影响。所以应该在塔上安装一些设备,这些设备应该提前感知温度、湿度等天气因素。本文介绍了一种用于气象参数测量的输电线路监测系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement of Weather Parameters via Transmission Line Monitoring System for Load Forecasting
Climate has significant impact on generation, transmission and demand of electricity. There is need to manage weather and climate effects to avoid penalties due to incorrectly predicted demand. The effect of weather changes is seen through fluctuation of electricity demand. Electricity demand is influenced by temperature, wind speed, humidity, precipitation and cloud cover. This further effects practically demand for air condidtioning, space heating, refrigeration and water pumping loads. This changes the peak demand and 24 hour demand. Transmission systems are found to be sensitive through thermal constraints and faults caused by extreme weather conditions. Demand levels are also weather sensitive. Thus all these pose serious challenges to electicity supply industry. It is also true that the forecasted load by load forecasters at load dispatch center, depend on the reliability of line that weather it is conveying that much of MW share to all related areas. Transmission system should be protected from weather effects. So proper means like some type of devices should be equipped over the tower which should sense the weather factors like temperature, humidity etc in prior. This paper presents the device named transmission line monitoring system for the measurement of weather parameters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信