具有互补约束的不平衡三相电力系统电压稳定性分析

G. Carpinelli, P. Caramia, P. Varilone
{"title":"具有互补约束的不平衡三相电力系统电压稳定性分析","authors":"G. Carpinelli, P. Caramia, P. Varilone","doi":"10.1109/EEEIC-2.2013.6737874","DOIUrl":null,"url":null,"abstract":"Voltage stability has become a fundamental issue in the new, liberalized markets due to the fact that the new power systems are approaching more and more the stability limits. Then, several approaches were proposed in the relevant literature to find the critical conditions and the problem was faced also with reference to unbalanced three phase power systems. The unbalances, in fact, can be responsible of more critical stability conditions than in balanced power systems. Continuation power flow and optimal power flows were applied to analyze such conditions. In this paper a new three-phase optimal power flow is proposed that makes use of complementarity constraints to take into account the effect of reactive generation limits on voltage stability in unbalanced power systems. An application is presented on a test system highlighting the feasibility and the goodness of the proposed technique. Both load and line unbalances are taken into account to capture the dependence of voltage stability on the level of unbalances.","PeriodicalId":445295,"journal":{"name":"2013 13th International Conference on Environment and Electrical Engineering (EEEIC)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Voltage stability analysis in unbalanced three-phase power systems with complementarity constraints\",\"authors\":\"G. Carpinelli, P. Caramia, P. Varilone\",\"doi\":\"10.1109/EEEIC-2.2013.6737874\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Voltage stability has become a fundamental issue in the new, liberalized markets due to the fact that the new power systems are approaching more and more the stability limits. Then, several approaches were proposed in the relevant literature to find the critical conditions and the problem was faced also with reference to unbalanced three phase power systems. The unbalances, in fact, can be responsible of more critical stability conditions than in balanced power systems. Continuation power flow and optimal power flows were applied to analyze such conditions. In this paper a new three-phase optimal power flow is proposed that makes use of complementarity constraints to take into account the effect of reactive generation limits on voltage stability in unbalanced power systems. An application is presented on a test system highlighting the feasibility and the goodness of the proposed technique. Both load and line unbalances are taken into account to capture the dependence of voltage stability on the level of unbalances.\",\"PeriodicalId\":445295,\"journal\":{\"name\":\"2013 13th International Conference on Environment and Electrical Engineering (EEEIC)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 13th International Conference on Environment and Electrical Engineering (EEEIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EEEIC-2.2013.6737874\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 13th International Conference on Environment and Electrical Engineering (EEEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC-2.2013.6737874","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

由于新型电力系统越来越接近稳定极限,电压稳定问题已成为开放型市场的基本问题。然后,在相关文献中提出了几种寻找临界条件的方法,并参考了三相不平衡电力系统所面临的问题。事实上,与平衡电力系统相比,不平衡可能导致更为关键的稳定条件。用连续潮流和最优潮流分析了这种情况。本文提出了一种新的三相最优潮流,利用互补约束来考虑不平衡电力系统中无功限制对电压稳定性的影响。最后在一个测试系统上进行了应用,验证了该技术的可行性和优越性。考虑了负载和线路的不平衡,以捕捉电压稳定性对不平衡水平的依赖关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Voltage stability analysis in unbalanced three-phase power systems with complementarity constraints
Voltage stability has become a fundamental issue in the new, liberalized markets due to the fact that the new power systems are approaching more and more the stability limits. Then, several approaches were proposed in the relevant literature to find the critical conditions and the problem was faced also with reference to unbalanced three phase power systems. The unbalances, in fact, can be responsible of more critical stability conditions than in balanced power systems. Continuation power flow and optimal power flows were applied to analyze such conditions. In this paper a new three-phase optimal power flow is proposed that makes use of complementarity constraints to take into account the effect of reactive generation limits on voltage stability in unbalanced power systems. An application is presented on a test system highlighting the feasibility and the goodness of the proposed technique. Both load and line unbalances are taken into account to capture the dependence of voltage stability on the level of unbalances.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信