{"title":"超导故障限流器减轻直流-高压直流系统直流线路故障的影响","authors":"P. Manohar, W. Ahmed","doi":"10.1109/EPSCICON.2012.6175282","DOIUrl":null,"url":null,"abstract":"Voltage source converter based HVDC systems involving overhead transmission lines are prone to severe over-voltages during line faults. At present, they find applications only in back to back and/or underground cable transmission, with low power ratings. A conventional HVDC system suppresses the dc fault very well with the controllers and smoothing reactors while the same is not true with voltage source converter based HVDC systems. This necessitates the operation of some kind of protective devices. A superconducting fault current limiter, in this regard, is a possible device which can mitigate the effects of dc line faults. In this work, it is aimed to evaluate the dynamic performance of VSC-HVDC system integrated with a superconducting fault current limiter. The resistive superconducting fault current limiter is modeled in MATLAB and is interfaced with low voltage VSC-HVDC system, in PSCAD/EMTDC environment. The results of analysis for various ac and dc fault conditions are presented.","PeriodicalId":143947,"journal":{"name":"2012 International Conference on Power, Signals, Controls and Computation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"51","resultStr":"{\"title\":\"Superconducting fault current limiter to mitigate the effect of DC line fault in VSC-HVDC system\",\"authors\":\"P. Manohar, W. Ahmed\",\"doi\":\"10.1109/EPSCICON.2012.6175282\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Voltage source converter based HVDC systems involving overhead transmission lines are prone to severe over-voltages during line faults. At present, they find applications only in back to back and/or underground cable transmission, with low power ratings. A conventional HVDC system suppresses the dc fault very well with the controllers and smoothing reactors while the same is not true with voltage source converter based HVDC systems. This necessitates the operation of some kind of protective devices. A superconducting fault current limiter, in this regard, is a possible device which can mitigate the effects of dc line faults. In this work, it is aimed to evaluate the dynamic performance of VSC-HVDC system integrated with a superconducting fault current limiter. The resistive superconducting fault current limiter is modeled in MATLAB and is interfaced with low voltage VSC-HVDC system, in PSCAD/EMTDC environment. The results of analysis for various ac and dc fault conditions are presented.\",\"PeriodicalId\":143947,\"journal\":{\"name\":\"2012 International Conference on Power, Signals, Controls and Computation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"51\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Power, Signals, Controls and Computation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPSCICON.2012.6175282\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Power, Signals, Controls and Computation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPSCICON.2012.6175282","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 51

摘要

基于电压源变换器的架空输电系统在线路故障时容易出现严重过电压。目前,它们仅应用于背靠背和/或地下电缆传输,具有低额定功率。传统直流输电系统采用控制器和平滑电抗器能很好地抑制直流故障,而基于电压源变换器的直流输电系统则不能很好地抑制直流故障。这就需要某种保护装置的操作。在这方面,超导故障限流器是一种可能的装置,可以减轻直流线路故障的影响。本研究的目的是评估超导故障限流器集成的vdc - hvdc系统的动态性能。利用MATLAB对电阻式超导故障限流器进行建模,并在PSCAD/EMTDC环境下与低压vdc - hvdc系统接口。给出了各种交流和直流故障条件下的分析结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Superconducting fault current limiter to mitigate the effect of DC line fault in VSC-HVDC system
Voltage source converter based HVDC systems involving overhead transmission lines are prone to severe over-voltages during line faults. At present, they find applications only in back to back and/or underground cable transmission, with low power ratings. A conventional HVDC system suppresses the dc fault very well with the controllers and smoothing reactors while the same is not true with voltage source converter based HVDC systems. This necessitates the operation of some kind of protective devices. A superconducting fault current limiter, in this regard, is a possible device which can mitigate the effects of dc line faults. In this work, it is aimed to evaluate the dynamic performance of VSC-HVDC system integrated with a superconducting fault current limiter. The resistive superconducting fault current limiter is modeled in MATLAB and is interfaced with low voltage VSC-HVDC system, in PSCAD/EMTDC environment. The results of analysis for various ac and dc fault conditions are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信