Volodymyr A. Lytvynchuk, M. Kaplin, N. Bolotnyi, O. Karmazin
{"title":"欧洲电网普遍低频减载方案的实施:挑战与机遇","authors":"Volodymyr A. Lytvynchuk, M. Kaplin, N. Bolotnyi, O. Karmazin","doi":"10.1109/ESS50319.2020.9160052","DOIUrl":null,"url":null,"abstract":"This paper analyzes the regulatory document “Continental Europe Operation Handbook Policy 5: Emergency Operations”, which was prepared by experts of the European Network of Electricity Transmission System Operators (ENTSO - E) to focus national networks on a single conceptual model for creating (and fine tuning) an automatic under frequency load shedding (UFLS) scheme. The ENTSO-E proposed for the Regional Group Continental Europe a general under frequency load shedding scheme, which must be implemented taking into account the individual features (properties) of the national network. Given that Policy 5 is an important document, the implementation of which is a prerequisite of security and system stability not only of a separate national grid, but also adjacent power systems, the authors aimed to test perspectives for UFLS development according to Policy 5 binding requirements in a case study for Ukrainian power system.","PeriodicalId":169630,"journal":{"name":"2020 IEEE 7th International Conference on Energy Smart Systems (ESS)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Implementation of General Under-frequency Load Shedding Scheme in European Network: challenges and opportunities\",\"authors\":\"Volodymyr A. Lytvynchuk, M. Kaplin, N. Bolotnyi, O. Karmazin\",\"doi\":\"10.1109/ESS50319.2020.9160052\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper analyzes the regulatory document “Continental Europe Operation Handbook Policy 5: Emergency Operations”, which was prepared by experts of the European Network of Electricity Transmission System Operators (ENTSO - E) to focus national networks on a single conceptual model for creating (and fine tuning) an automatic under frequency load shedding (UFLS) scheme. The ENTSO-E proposed for the Regional Group Continental Europe a general under frequency load shedding scheme, which must be implemented taking into account the individual features (properties) of the national network. Given that Policy 5 is an important document, the implementation of which is a prerequisite of security and system stability not only of a separate national grid, but also adjacent power systems, the authors aimed to test perspectives for UFLS development according to Policy 5 binding requirements in a case study for Ukrainian power system.\",\"PeriodicalId\":169630,\"journal\":{\"name\":\"2020 IEEE 7th International Conference on Energy Smart Systems (ESS)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE 7th International Conference on Energy Smart Systems (ESS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESS50319.2020.9160052\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 7th International Conference on Energy Smart Systems (ESS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESS50319.2020.9160052","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Implementation of General Under-frequency Load Shedding Scheme in European Network: challenges and opportunities
This paper analyzes the regulatory document “Continental Europe Operation Handbook Policy 5: Emergency Operations”, which was prepared by experts of the European Network of Electricity Transmission System Operators (ENTSO - E) to focus national networks on a single conceptual model for creating (and fine tuning) an automatic under frequency load shedding (UFLS) scheme. The ENTSO-E proposed for the Regional Group Continental Europe a general under frequency load shedding scheme, which must be implemented taking into account the individual features (properties) of the national network. Given that Policy 5 is an important document, the implementation of which is a prerequisite of security and system stability not only of a separate national grid, but also adjacent power systems, the authors aimed to test perspectives for UFLS development according to Policy 5 binding requirements in a case study for Ukrainian power system.