{"title":"根据单台变压器的记录值,从初级和次级的电压和电压中修正调压开关的位置","authors":"S. Spremić, Danko Obradovic","doi":"10.46793/eee21-4.78s","DOIUrl":null,"url":null,"abstract":"The paper considers the possibility of direct error correction when determining the position of the control switch from the primary and secondary voltages of individual transformers that have a larger number of recorded measured values of voltage and current in a smaller or larger load range. The direct correction builds on the previously performed error correction from the voltage drop on the transformer impedance, which is used to calculate the position of the control switch using voltage. Direct correction is performed by determining the mean value of all points and then subtracting the determined mean value from the value of individual points.","PeriodicalId":236996,"journal":{"name":"Energija, ekonomija, ekologija","volume":"81 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Korekcija određivanja položaja regulacione preklopke iz struja i napona primara i sekundara po snimljenim vrednostima pojedinačnog transformatora\",\"authors\":\"S. Spremić, Danko Obradovic\",\"doi\":\"10.46793/eee21-4.78s\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper considers the possibility of direct error correction when determining the position of the control switch from the primary and secondary voltages of individual transformers that have a larger number of recorded measured values of voltage and current in a smaller or larger load range. The direct correction builds on the previously performed error correction from the voltage drop on the transformer impedance, which is used to calculate the position of the control switch using voltage. Direct correction is performed by determining the mean value of all points and then subtracting the determined mean value from the value of individual points.\",\"PeriodicalId\":236996,\"journal\":{\"name\":\"Energija, ekonomija, ekologija\",\"volume\":\"81 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energija, ekonomija, ekologija\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46793/eee21-4.78s\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energija, ekonomija, ekologija","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46793/eee21-4.78s","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Korekcija određivanja položaja regulacione preklopke iz struja i napona primara i sekundara po snimljenim vrednostima pojedinačnog transformatora
The paper considers the possibility of direct error correction when determining the position of the control switch from the primary and secondary voltages of individual transformers that have a larger number of recorded measured values of voltage and current in a smaller or larger load range. The direct correction builds on the previously performed error correction from the voltage drop on the transformer impedance, which is used to calculate the position of the control switch using voltage. Direct correction is performed by determining the mean value of all points and then subtracting the determined mean value from the value of individual points.