差分信号的研究:稳定准确的混合模式转换和差分s参数的提取

H. Tran, L. Barannyk, A. Elshabini, F. Barlow
{"title":"差分信号的研究:稳定准确的混合模式转换和差分s参数的提取","authors":"H. Tran, L. Barannyk, A. Elshabini, F. Barlow","doi":"10.1109/WMED.2015.7093953","DOIUrl":null,"url":null,"abstract":"Low voltage differential signaling (LVDS) in high-speed digital systems is utilized to effectively reduce EMI and improve signal quality. Mixed-mode S-parameters are a more general way to characterize a differential network. Therefore, an accurate extraction of mixed-mode S-parameters from single-ended S- parameters is critical for Signal and Power Integrity co-simulation where SSN is generated mainly by high-frequency interconnects. The standard conversion between mixed-mode and single-ended S-parameters involves inversion of a transformation matrix. If there is no coupling, this transformation matrix is orthogonal and numerical inversion can be done accurately. In the presence of coupling, the transformation matrix depends on S-parameters and may become ill-conditioned, i.e. has high condition number, for some values of physical parameters resulting in unstable inversion of the transformation matrix and leading to highly inaccurate converted mixed-mode S-parameters. To analyze the possibility of ill-conditioning, we consider two cases: broadside coupled striplines and coupled microstrip pairs. We find that in both cases when two transmission lines are strongly coupled, the condition number becomes very large. In this case, regularized methods from the theory of ill-posed problems should be used, for example, the truncated SVD method, to obtain accurate mixed-mode S- parameters.","PeriodicalId":251088,"journal":{"name":"2015 IEEE Workshop on Microelectronics and Electron Devices (WMED)","volume":"394 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A Study of Differential Signaling: Stable and Accurate Mixed-Mode Conversion and Extraction of Differential S-Parameters\",\"authors\":\"H. Tran, L. Barannyk, A. Elshabini, F. Barlow\",\"doi\":\"10.1109/WMED.2015.7093953\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Low voltage differential signaling (LVDS) in high-speed digital systems is utilized to effectively reduce EMI and improve signal quality. Mixed-mode S-parameters are a more general way to characterize a differential network. Therefore, an accurate extraction of mixed-mode S-parameters from single-ended S- parameters is critical for Signal and Power Integrity co-simulation where SSN is generated mainly by high-frequency interconnects. The standard conversion between mixed-mode and single-ended S-parameters involves inversion of a transformation matrix. If there is no coupling, this transformation matrix is orthogonal and numerical inversion can be done accurately. In the presence of coupling, the transformation matrix depends on S-parameters and may become ill-conditioned, i.e. has high condition number, for some values of physical parameters resulting in unstable inversion of the transformation matrix and leading to highly inaccurate converted mixed-mode S-parameters. To analyze the possibility of ill-conditioning, we consider two cases: broadside coupled striplines and coupled microstrip pairs. We find that in both cases when two transmission lines are strongly coupled, the condition number becomes very large. In this case, regularized methods from the theory of ill-posed problems should be used, for example, the truncated SVD method, to obtain accurate mixed-mode S- parameters.\",\"PeriodicalId\":251088,\"journal\":{\"name\":\"2015 IEEE Workshop on Microelectronics and Electron Devices (WMED)\",\"volume\":\"394 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Workshop on Microelectronics and Electron Devices (WMED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/WMED.2015.7093953\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Workshop on Microelectronics and Electron Devices (WMED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WMED.2015.7093953","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

在高速数字系统中,利用低压差分信号(LVDS)可以有效地降低电磁干扰,提高信号质量。混合模式s参数是表征微分网络的一种更通用的方法。因此,从单端S参数中准确提取混合模式S参数对于信号和功率完整性联合仿真至关重要,其中SSN主要由高频互连产生。混合模式和单端s参数之间的标准转换涉及变换矩阵的反演。如果不存在耦合,则该变换矩阵是正交的,可以精确地进行数值反演。在存在耦合的情况下,变换矩阵依赖于s参数,对于某些物理参数值可能会出现病态,即条件数过高,从而导致变换矩阵的反演不稳定,从而导致转换的混合模式s参数非常不准确。为了分析病态的可能性,我们考虑了两种情况:宽幅耦合带状线和耦合微带对。我们发现,在两种情况下,当两条传输线强耦合时,条件数变得非常大。在这种情况下,需要使用不适定问题理论中的正则化方法,例如截断SVD方法来获得精确的混合模S-参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Study of Differential Signaling: Stable and Accurate Mixed-Mode Conversion and Extraction of Differential S-Parameters
Low voltage differential signaling (LVDS) in high-speed digital systems is utilized to effectively reduce EMI and improve signal quality. Mixed-mode S-parameters are a more general way to characterize a differential network. Therefore, an accurate extraction of mixed-mode S-parameters from single-ended S- parameters is critical for Signal and Power Integrity co-simulation where SSN is generated mainly by high-frequency interconnects. The standard conversion between mixed-mode and single-ended S-parameters involves inversion of a transformation matrix. If there is no coupling, this transformation matrix is orthogonal and numerical inversion can be done accurately. In the presence of coupling, the transformation matrix depends on S-parameters and may become ill-conditioned, i.e. has high condition number, for some values of physical parameters resulting in unstable inversion of the transformation matrix and leading to highly inaccurate converted mixed-mode S-parameters. To analyze the possibility of ill-conditioning, we consider two cases: broadside coupled striplines and coupled microstrip pairs. We find that in both cases when two transmission lines are strongly coupled, the condition number becomes very large. In this case, regularized methods from the theory of ill-posed problems should be used, for example, the truncated SVD method, to obtain accurate mixed-mode S- parameters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信