电磁干扰耦合到心脏起搏器电极

S. Schenke, F. Sabath, F. Sutter, M. Clemens, S. Dickmann
{"title":"电磁干扰耦合到心脏起搏器电极","authors":"S. Schenke, F. Sabath, F. Sutter, M. Clemens, S. Dickmann","doi":"10.1109/EMCEUROPE.2008.4786824","DOIUrl":null,"url":null,"abstract":"Cardiac pacemakers (PMKs) are vital for many persons sufferering from heart diseases, and a malfunction of those devices can have terrible consequences for their wearers. The main source of malfunctions is the PMK's electrode which acts linke an antenna. An incident electromagnetic field can couple into the electrode and cause an interference voltage at the PMK's input connector. This signal can be misinterpreted as the electrocardiogram (ECG) of the heart and mislead the PMK to wrong reactions. This paper presents the results of series simulations for calculating the maximum input voltage as a function of the electical field strength of a plane wave penetrating the human body.","PeriodicalId":133902,"journal":{"name":"2008 International Symposium on Electromagnetic Compatibility - EMC Europe","volume":"213 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Electromagnetic interference coupling into cardiac pacemaker electrodes\",\"authors\":\"S. Schenke, F. Sabath, F. Sutter, M. Clemens, S. Dickmann\",\"doi\":\"10.1109/EMCEUROPE.2008.4786824\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cardiac pacemakers (PMKs) are vital for many persons sufferering from heart diseases, and a malfunction of those devices can have terrible consequences for their wearers. The main source of malfunctions is the PMK's electrode which acts linke an antenna. An incident electromagnetic field can couple into the electrode and cause an interference voltage at the PMK's input connector. This signal can be misinterpreted as the electrocardiogram (ECG) of the heart and mislead the PMK to wrong reactions. This paper presents the results of series simulations for calculating the maximum input voltage as a function of the electical field strength of a plane wave penetrating the human body.\",\"PeriodicalId\":133902,\"journal\":{\"name\":\"2008 International Symposium on Electromagnetic Compatibility - EMC Europe\",\"volume\":\"213 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 International Symposium on Electromagnetic Compatibility - EMC Europe\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCEUROPE.2008.4786824\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 International Symposium on Electromagnetic Compatibility - EMC Europe","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEUROPE.2008.4786824","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

心脏起搏器(pmk)对许多患有心脏病的人来说是至关重要的,这些设备的故障可能会给佩戴者带来可怕的后果。故障的主要来源是PMK的电极,它像天线一样起作用。入射电磁场可以耦合到电极中,并在PMK的输入连接器处产生干扰电压。这个信号可能被误解为心脏的心电图(ECG),误导PMK做出错误的反应。本文给出了平面波穿透人体时最大输入电压随电场强度变化的一系列模拟结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electromagnetic interference coupling into cardiac pacemaker electrodes
Cardiac pacemakers (PMKs) are vital for many persons sufferering from heart diseases, and a malfunction of those devices can have terrible consequences for their wearers. The main source of malfunctions is the PMK's electrode which acts linke an antenna. An incident electromagnetic field can couple into the electrode and cause an interference voltage at the PMK's input connector. This signal can be misinterpreted as the electrocardiogram (ECG) of the heart and mislead the PMK to wrong reactions. This paper presents the results of series simulations for calculating the maximum input voltage as a function of the electical field strength of a plane wave penetrating the human body.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信