[使用99mTc-DTPA和i131 -hippurate同时测定斜坡间隙中单个血液样本的GRF和ERPF(有效肾血浆流量)]。

L Schumann, G Esther, P W Wüstenberg, B Hortian
{"title":"[使用99mTc-DTPA和i131 -hippurate同时测定斜坡间隙中单个血液样本的GRF和ERPF(有效肾血浆流量)]。","authors":"L Schumann,&nbsp;G Esther,&nbsp;P W Wüstenberg,&nbsp;B Hortian","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In patients with various indications to renal split function diagnostics the plasma slope clearance of the Tc99m-DTPA and J131-Hippurate to the estimation of GFR and ERPF were performed with two or three blood samples in the monocompartment model (1 KM). In comparison these functional parameters were calculated on the basis of the only least blood sample (single-point procedure--EPV). The results of linear regression GFR (1 KM) = 12.7 + 0.978 * GFR (EPV), r = 0.986, N = 102 or ERPF (1 KM) = 22 + 1.13 * ERPF (EPV), r = 0.889, N = 68 may recommend the use as patient-safe procedure especially in poor venous access. Two short BASIC programs for estimation of GFR and ERPF are presented and the error ranges discussed.</p>","PeriodicalId":76863,"journal":{"name":"Zeitschrift fur Urologie und Nephrologie","volume":"83 7","pages":"391-7"},"PeriodicalIF":0.0000,"publicationDate":"1990-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Simultaneous determination of the GRF and the ERPF (effective renal plasma flow) using a single blood sample in the slope clearance with 99mTc-DTPA and I 131-hippurate].\",\"authors\":\"L Schumann,&nbsp;G Esther,&nbsp;P W Wüstenberg,&nbsp;B Hortian\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In patients with various indications to renal split function diagnostics the plasma slope clearance of the Tc99m-DTPA and J131-Hippurate to the estimation of GFR and ERPF were performed with two or three blood samples in the monocompartment model (1 KM). In comparison these functional parameters were calculated on the basis of the only least blood sample (single-point procedure--EPV). The results of linear regression GFR (1 KM) = 12.7 + 0.978 * GFR (EPV), r = 0.986, N = 102 or ERPF (1 KM) = 22 + 1.13 * ERPF (EPV), r = 0.889, N = 68 may recommend the use as patient-safe procedure especially in poor venous access. Two short BASIC programs for estimation of GFR and ERPF are presented and the error ranges discussed.</p>\",\"PeriodicalId\":76863,\"journal\":{\"name\":\"Zeitschrift fur Urologie und Nephrologie\",\"volume\":\"83 7\",\"pages\":\"391-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zeitschrift fur Urologie und Nephrologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur Urologie und Nephrologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在肾分裂功能诊断有各种适应症的患者中,在单室模型(1 KM)中,用2个或3个血液样本进行Tc99m-DTPA和J131-Hippurate对GFR和ERPF估计的血浆斜率清除率。相比之下,这些功能参数是根据唯一最少的血液样本(单点程序-EPV)计算的。线性回归结果表明,GFR (1 KM) = 12.7 + 0.978 * GFR (EPV), r = 0.986, N = 102或ERPF (1 KM) = 22 + 1.13 * ERPF (EPV), r = 0.889, N = 68可推荐作为患者安全的操作,特别是在静脉通路不良的情况下。给出了GFR和ERPF估计的两个简短BASIC程序,并讨论了误差范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Simultaneous determination of the GRF and the ERPF (effective renal plasma flow) using a single blood sample in the slope clearance with 99mTc-DTPA and I 131-hippurate].

In patients with various indications to renal split function diagnostics the plasma slope clearance of the Tc99m-DTPA and J131-Hippurate to the estimation of GFR and ERPF were performed with two or three blood samples in the monocompartment model (1 KM). In comparison these functional parameters were calculated on the basis of the only least blood sample (single-point procedure--EPV). The results of linear regression GFR (1 KM) = 12.7 + 0.978 * GFR (EPV), r = 0.986, N = 102 or ERPF (1 KM) = 22 + 1.13 * ERPF (EPV), r = 0.889, N = 68 may recommend the use as patient-safe procedure especially in poor venous access. Two short BASIC programs for estimation of GFR and ERPF are presented and the error ranges discussed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信