通过对重合闸时间电流曲线进行适当的测试,增强了分段性

L. Toth, A. Hannah
{"title":"通过对重合闸时间电流曲线进行适当的测试,增强了分段性","authors":"L. Toth, A. Hannah","doi":"10.1109/REPCON.1994.326253","DOIUrl":null,"url":null,"abstract":"The recent proliferation of software packages containing computer generated time-current curves have helped to free distribution engineers from curve-tracing using transparencies on electric light tables. The new software packages offer speed, flexibility, and ease of operation that enable the distribution engineer to provide enhanced sectionalizing for radial distribution systems. Single phase hydraulic oil circuit reclosers usually comprise a large portion of rural distribution systems and hence, represent a huge percentage of the total sectionalizing scheme. Unfortunately rebuilt oil circuit reclosers do not always exhibit time-current characteristics as depicted on computer generated or manual light tables. This paper summarizes considerations for proper recloser-recloser and recloser-fuse coordination. The paper also presents an approach and method of testing time-current characteristics of single phase hydraulic reclosers with oil or vacuum interrupters. Computer light table software is used to confirm if the \"as-tested\" time-current characteristics fall within specified tolerance limits.<<ETX>>","PeriodicalId":182639,"journal":{"name":"Proceedings of 1994 IEEE Rural Electric Power Conference","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Enhanced sectionalizing through proper testing of recloser time current curves\",\"authors\":\"L. Toth, A. Hannah\",\"doi\":\"10.1109/REPCON.1994.326253\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The recent proliferation of software packages containing computer generated time-current curves have helped to free distribution engineers from curve-tracing using transparencies on electric light tables. The new software packages offer speed, flexibility, and ease of operation that enable the distribution engineer to provide enhanced sectionalizing for radial distribution systems. Single phase hydraulic oil circuit reclosers usually comprise a large portion of rural distribution systems and hence, represent a huge percentage of the total sectionalizing scheme. Unfortunately rebuilt oil circuit reclosers do not always exhibit time-current characteristics as depicted on computer generated or manual light tables. This paper summarizes considerations for proper recloser-recloser and recloser-fuse coordination. The paper also presents an approach and method of testing time-current characteristics of single phase hydraulic reclosers with oil or vacuum interrupters. Computer light table software is used to confirm if the \\\"as-tested\\\" time-current characteristics fall within specified tolerance limits.<<ETX>>\",\"PeriodicalId\":182639,\"journal\":{\"name\":\"Proceedings of 1994 IEEE Rural Electric Power Conference\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-04-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1994 IEEE Rural Electric Power Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/REPCON.1994.326253\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1994 IEEE Rural Electric Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/REPCON.1994.326253","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

最近,包含计算机生成的时间-电流曲线的软件包的激增,帮助配电工程师从使用电光台上的透明材料进行曲线跟踪中解脱出来。新的软件包具有速度、灵活性和易于操作的特点,使配电工程师能够为径向配电系统提供增强的分区。单相液压油路重合闸通常占农村配电系统的很大一部分,因此在总分段方案中占很大比例。不幸的是,重建的油路复位器并不总是表现出计算机生成或手动光表所描述的时间-电流特性。本文总结了合闸-合闸和合闸-熔断器配合的注意事项。本文还介绍了一种测试带油断路或真空断路的单相液压重开关时流特性的方法和方法。使用计算机光表软件来确认“测试”时间-电流特性是否落在规定的公差范围内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Enhanced sectionalizing through proper testing of recloser time current curves
The recent proliferation of software packages containing computer generated time-current curves have helped to free distribution engineers from curve-tracing using transparencies on electric light tables. The new software packages offer speed, flexibility, and ease of operation that enable the distribution engineer to provide enhanced sectionalizing for radial distribution systems. Single phase hydraulic oil circuit reclosers usually comprise a large portion of rural distribution systems and hence, represent a huge percentage of the total sectionalizing scheme. Unfortunately rebuilt oil circuit reclosers do not always exhibit time-current characteristics as depicted on computer generated or manual light tables. This paper summarizes considerations for proper recloser-recloser and recloser-fuse coordination. The paper also presents an approach and method of testing time-current characteristics of single phase hydraulic reclosers with oil or vacuum interrupters. Computer light table software is used to confirm if the "as-tested" time-current characteristics fall within specified tolerance limits.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信