{"title":"通过分区优化微控制器","authors":"G. Tarroux, B. Rouzeyre, G. Sagnes","doi":"10.1109/EDAC.1991.206427","DOIUrl":null,"url":null,"abstract":"Presents a new partitioning method for finite state machines (FSMs). The method is particularly well suited for mu -controller circuits. It consists in grouping the mu -instructions of the control graph into classes according to a compatibility property of the output values. Only one sequence of output values is then generated for all mu -instructions of a given class. The resulting structure is composed of three machines: a state machine which generates the next states, a command machine and a filter machine. The command outputs and the filter outputs are merged via a logical AND to obtain the final outputs. This structure leads to an area reduction of 34% to 65% for the examples presented.<<ETX>>","PeriodicalId":425087,"journal":{"name":"Proceedings of the European Conference on Design Automation.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Optimization of microcontrollers by partitioning\",\"authors\":\"G. Tarroux, B. Rouzeyre, G. Sagnes\",\"doi\":\"10.1109/EDAC.1991.206427\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Presents a new partitioning method for finite state machines (FSMs). The method is particularly well suited for mu -controller circuits. It consists in grouping the mu -instructions of the control graph into classes according to a compatibility property of the output values. Only one sequence of output values is then generated for all mu -instructions of a given class. The resulting structure is composed of three machines: a state machine which generates the next states, a command machine and a filter machine. The command outputs and the filter outputs are merged via a logical AND to obtain the final outputs. This structure leads to an area reduction of 34% to 65% for the examples presented.<<ETX>>\",\"PeriodicalId\":425087,\"journal\":{\"name\":\"Proceedings of the European Conference on Design Automation.\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the European Conference on Design Automation.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EDAC.1991.206427\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the European Conference on Design Automation.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDAC.1991.206427","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Presents a new partitioning method for finite state machines (FSMs). The method is particularly well suited for mu -controller circuits. It consists in grouping the mu -instructions of the control graph into classes according to a compatibility property of the output values. Only one sequence of output values is then generated for all mu -instructions of a given class. The resulting structure is composed of three machines: a state machine which generates the next states, a command machine and a filter machine. The command outputs and the filter outputs are merged via a logical AND to obtain the final outputs. This structure leads to an area reduction of 34% to 65% for the examples presented.<>