人体运动界面上模糊人体运动的吸收

S. Yokota, H. Hashimoto, D. Chugo, Y. Ohyama, Jinhua She
{"title":"人体运动界面上模糊人体运动的吸收","authors":"S. Yokota, H. Hashimoto, D. Chugo, Y. Ohyama, Jinhua She","doi":"10.1109/ISIE.2011.5984270","DOIUrl":null,"url":null,"abstract":"This research focuses on the electric wheelchair controlled by Human Body Motion Interface (HBMI). HBMI uses the body motion which is caused by the voluntary motion. From our previous research, it has been confirmed that HBMI, which uses the center of weight on the pressure sensor attached on the backrest, has the ability of an interface. However the problem has also remained. The velocities of each wheel have determined based on the error between initial and current position of center of weight. When user tries to stop the wheelchair, user has to rigorously return the center of weight to the initial position. Therefore, if a slight error remains on the center of weight, the wheelchair is not able to stop exactly. This paper absorbs ambiguous human motion, and proposes the control scheme to prevent miss operation of wheelchair caused by slight variation of the center of weight.","PeriodicalId":162453,"journal":{"name":"2011 IEEE International Symposium on Industrial Electronics","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Absorption of ambiguous human motion on Human Body Motion Interface\",\"authors\":\"S. Yokota, H. Hashimoto, D. Chugo, Y. Ohyama, Jinhua She\",\"doi\":\"10.1109/ISIE.2011.5984270\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research focuses on the electric wheelchair controlled by Human Body Motion Interface (HBMI). HBMI uses the body motion which is caused by the voluntary motion. From our previous research, it has been confirmed that HBMI, which uses the center of weight on the pressure sensor attached on the backrest, has the ability of an interface. However the problem has also remained. The velocities of each wheel have determined based on the error between initial and current position of center of weight. When user tries to stop the wheelchair, user has to rigorously return the center of weight to the initial position. Therefore, if a slight error remains on the center of weight, the wheelchair is not able to stop exactly. This paper absorbs ambiguous human motion, and proposes the control scheme to prevent miss operation of wheelchair caused by slight variation of the center of weight.\",\"PeriodicalId\":162453,\"journal\":{\"name\":\"2011 IEEE International Symposium on Industrial Electronics\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE International Symposium on Industrial Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2011.5984270\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Symposium on Industrial Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2011.5984270","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文主要研究基于人体运动接口(HBMI)控制的电动轮椅。HBMI使用由自主运动引起的身体运动。从我们之前的研究中,已经证实HBMI是利用连接在靠背上的压力传感器的重心,具有接口的能力。然而,这个问题仍然存在。每个车轮的速度是根据初始和当前重心位置之间的误差确定的。当使用者试图停止轮椅时,使用者必须严格地将重心恢复到初始位置。因此,如果重心有一点误差,轮椅就不能完全停住。本文吸收了模糊的人体运动,提出了防止因重心轻微变化而导致轮椅误操作的控制方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Absorption of ambiguous human motion on Human Body Motion Interface
This research focuses on the electric wheelchair controlled by Human Body Motion Interface (HBMI). HBMI uses the body motion which is caused by the voluntary motion. From our previous research, it has been confirmed that HBMI, which uses the center of weight on the pressure sensor attached on the backrest, has the ability of an interface. However the problem has also remained. The velocities of each wheel have determined based on the error between initial and current position of center of weight. When user tries to stop the wheelchair, user has to rigorously return the center of weight to the initial position. Therefore, if a slight error remains on the center of weight, the wheelchair is not able to stop exactly. This paper absorbs ambiguous human motion, and proposes the control scheme to prevent miss operation of wheelchair caused by slight variation of the center of weight.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信