{"title":"逆变器馈电脉冲下中压定子棒接地壁绝缘评价","authors":"S. Ul Haq, S. Jayaram, E. Cherney","doi":"10.1109/CEIDP.2006.311970","DOIUrl":null,"url":null,"abstract":"In this research work, the behavior of medium voltage stator bar groundwall insulation that is subjected to steep-front voltage pulses, at various repetition rates and temperatures, is studied. The test conditions include; pulse voltage amplitudes up to 3.5 kVp, pulse switching frequencies up to 3 kHz, and in ambient temperatures of 23 and 155 degC. During the aging process, the surface temperature is monitored with an infrared camera as a means for determining the locations of the highest temperature and therefore the highest regions of PD activity. Visual observations confirm degradation of the groundwall insulation in the regions of highest temperature and PD measurements show increased activity and reduced PD inception with aging.","PeriodicalId":219099,"journal":{"name":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","volume":"102 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Evaluation of Medium Voltage Stator Bar Groundwall Insulation under Inverter-Fed Pulses\",\"authors\":\"S. Ul Haq, S. Jayaram, E. Cherney\",\"doi\":\"10.1109/CEIDP.2006.311970\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this research work, the behavior of medium voltage stator bar groundwall insulation that is subjected to steep-front voltage pulses, at various repetition rates and temperatures, is studied. The test conditions include; pulse voltage amplitudes up to 3.5 kVp, pulse switching frequencies up to 3 kHz, and in ambient temperatures of 23 and 155 degC. During the aging process, the surface temperature is monitored with an infrared camera as a means for determining the locations of the highest temperature and therefore the highest regions of PD activity. Visual observations confirm degradation of the groundwall insulation in the regions of highest temperature and PD measurements show increased activity and reduced PD inception with aging.\",\"PeriodicalId\":219099,\"journal\":{\"name\":\"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"102 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2006.311970\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2006.311970","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在本研究工作中,研究了在不同的重复频率和温度下,中压定子棒接地壁绝缘在陡坡前电压脉冲作用下的行为。试验条件包括:脉冲电压幅值高达3.5 kVp,脉冲开关频率高达3 kHz,环境温度为23和155℃。在老化过程中,用红外摄像机监测表面温度,以确定最高温度的位置,从而确定PD活动的最高区域。目视观察证实,在温度最高的区域,地墙绝缘层发生了退化,PD测量显示,随着老化,活性增加,PD开始减少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Medium Voltage Stator Bar Groundwall Insulation under Inverter-Fed Pulses
In this research work, the behavior of medium voltage stator bar groundwall insulation that is subjected to steep-front voltage pulses, at various repetition rates and temperatures, is studied. The test conditions include; pulse voltage amplitudes up to 3.5 kVp, pulse switching frequencies up to 3 kHz, and in ambient temperatures of 23 and 155 degC. During the aging process, the surface temperature is monitored with an infrared camera as a means for determining the locations of the highest temperature and therefore the highest regions of PD activity. Visual observations confirm degradation of the groundwall insulation in the regions of highest temperature and PD measurements show increased activity and reduced PD inception with aging.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信