{"title":"高压直流广域功率振荡阻尼控制:以澳大利亚等效系统为例","authors":"Y. Pipelzadeh, B. Chaudhuri, T. Green","doi":"10.1109/PES.2010.5589941","DOIUrl":null,"url":null,"abstract":"A case study on the Australian equivalent system - recently adopted as an IEEE benchmark for stability studies - is presented here to illustrate power oscillation damping through HVDC links. Wide-area signals are used for supplementary modulation of the HVDC power order driven through a multivariable controller. The test case is set up in DIgSILENT and benchmarked against the standard results. Linearized model around the nominal condition is obtained by using subspace identification on a set of measurements derived out of probing the system through the HVDC link. Modal analysis is carried out to identify a set of appropriate feedback signals for the controller. Pole-placement technique is used to design a multi-input, single-output (MISO) controller in two different frameworks - i) observer driven state feedback and ii) optimized lead-lag compensators. The effectiveness of HVDC modulation for power oscillation damping is validated through eigen-value analysis and non-linear simulation (in DIgSILENT) over a range of operating conditions.","PeriodicalId":177545,"journal":{"name":"IEEE PES General Meeting","volume":"78 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"39","resultStr":"{\"title\":\"Wide-area power oscillation damping control through HVDC: A case study on Australian equivalent system\",\"authors\":\"Y. Pipelzadeh, B. Chaudhuri, T. Green\",\"doi\":\"10.1109/PES.2010.5589941\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A case study on the Australian equivalent system - recently adopted as an IEEE benchmark for stability studies - is presented here to illustrate power oscillation damping through HVDC links. Wide-area signals are used for supplementary modulation of the HVDC power order driven through a multivariable controller. The test case is set up in DIgSILENT and benchmarked against the standard results. Linearized model around the nominal condition is obtained by using subspace identification on a set of measurements derived out of probing the system through the HVDC link. Modal analysis is carried out to identify a set of appropriate feedback signals for the controller. Pole-placement technique is used to design a multi-input, single-output (MISO) controller in two different frameworks - i) observer driven state feedback and ii) optimized lead-lag compensators. The effectiveness of HVDC modulation for power oscillation damping is validated through eigen-value analysis and non-linear simulation (in DIgSILENT) over a range of operating conditions.\",\"PeriodicalId\":177545,\"journal\":{\"name\":\"IEEE PES General Meeting\",\"volume\":\"78 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"39\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE PES General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2010.5589941\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE PES General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2010.5589941","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Wide-area power oscillation damping control through HVDC: A case study on Australian equivalent system
A case study on the Australian equivalent system - recently adopted as an IEEE benchmark for stability studies - is presented here to illustrate power oscillation damping through HVDC links. Wide-area signals are used for supplementary modulation of the HVDC power order driven through a multivariable controller. The test case is set up in DIgSILENT and benchmarked against the standard results. Linearized model around the nominal condition is obtained by using subspace identification on a set of measurements derived out of probing the system through the HVDC link. Modal analysis is carried out to identify a set of appropriate feedback signals for the controller. Pole-placement technique is used to design a multi-input, single-output (MISO) controller in two different frameworks - i) observer driven state feedback and ii) optimized lead-lag compensators. The effectiveness of HVDC modulation for power oscillation damping is validated through eigen-value analysis and non-linear simulation (in DIgSILENT) over a range of operating conditions.