电压互感器与估计算法对谐波同步量测量的综合影响

C. Laurano, S. Toscani, M. Zanoni, P. Castello, C. Muscas, P. Pegoraro
{"title":"电压互感器与估计算法对谐波同步量测量的综合影响","authors":"C. Laurano, S. Toscani, M. Zanoni, P. Castello, C. Muscas, P. Pegoraro","doi":"10.1109/I2MTC43012.2020.9128813","DOIUrl":null,"url":null,"abstract":"Nowadays the increased diffusion of nonlinear power electronics based devices in electric distribution grids has raised the interests towards power quality monitoring. In this respect, the use of synchronized harmonic phasors can be a powerful tool that allows identifying the sources of power quality issues such as harmonic disturbances. However, the impact of the uncertainty due to the employed voltage transformers and to the other devices that compose the measurement chain has to be analyzed. The aim of this work is investigating, through numerical simulations, the combined impact of the inductive instrument transformer and of the estimation algorithm on harmonic synchrophasor measurement. In particular, a detailed model of the voltage transformer considering core hysteresis has been employed.","PeriodicalId":227967,"journal":{"name":"2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","volume":"98 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Combined Impact of Voltage Transformer and Estimation Algorithm on Harmonic Synchrophasors Measurements\",\"authors\":\"C. Laurano, S. Toscani, M. Zanoni, P. Castello, C. Muscas, P. Pegoraro\",\"doi\":\"10.1109/I2MTC43012.2020.9128813\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nowadays the increased diffusion of nonlinear power electronics based devices in electric distribution grids has raised the interests towards power quality monitoring. In this respect, the use of synchronized harmonic phasors can be a powerful tool that allows identifying the sources of power quality issues such as harmonic disturbances. However, the impact of the uncertainty due to the employed voltage transformers and to the other devices that compose the measurement chain has to be analyzed. The aim of this work is investigating, through numerical simulations, the combined impact of the inductive instrument transformer and of the estimation algorithm on harmonic synchrophasor measurement. In particular, a detailed model of the voltage transformer considering core hysteresis has been employed.\",\"PeriodicalId\":227967,\"journal\":{\"name\":\"2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"volume\":\"98 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2MTC43012.2020.9128813\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC43012.2020.9128813","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

目前,基于非线性电力电子器件在配电网中的应用日益广泛,引起了人们对电能质量监测的关注。在这方面,使用同步谐波相量可以是一个强大的工具,可以识别电能质量问题的来源,如谐波干扰。然而,由于所使用的电压互感器和组成测量链的其他设备的不确定性的影响必须进行分析。本工作的目的是通过数值模拟,研究电感式互感器和估计算法对谐波同步量测量的综合影响。特别地,采用了考虑铁心磁滞的电压互感器的详细模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Combined Impact of Voltage Transformer and Estimation Algorithm on Harmonic Synchrophasors Measurements
Nowadays the increased diffusion of nonlinear power electronics based devices in electric distribution grids has raised the interests towards power quality monitoring. In this respect, the use of synchronized harmonic phasors can be a powerful tool that allows identifying the sources of power quality issues such as harmonic disturbances. However, the impact of the uncertainty due to the employed voltage transformers and to the other devices that compose the measurement chain has to be analyzed. The aim of this work is investigating, through numerical simulations, the combined impact of the inductive instrument transformer and of the estimation algorithm on harmonic synchrophasor measurement. In particular, a detailed model of the voltage transformer considering core hysteresis has been employed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信