基于磁场定向控制的双馈感应电机通用诊断方法

D. Casadei, F. Filippetti, C. Rossi, A. Stefani, A. Capolino, A. Yazidi
{"title":"基于磁场定向控制的双馈感应电机通用诊断方法","authors":"D. Casadei, F. Filippetti, C. Rossi, A. Stefani, A. Capolino, A. Yazidi","doi":"10.1109/DEMPED.2007.4393122","DOIUrl":null,"url":null,"abstract":"This paper presents a diagnostic technique for the detection of incipient electrical faults in a doubly fed induction machine (DFIM) used for variable speed generation. In this application the stator windings are directly connected to the grid, whereas a converter, which controls the rotor currents by means of a field oriented control (FOC) scheme, supplies the rotor. The aim of this paper is to introduce a new diagnostic technique based on the analysis of the rotor inverter output voltages. In particular it will be shown that the frequency analysis of these signals leads to an effective diagnostic procedure. The presented system is suitable to be easily plugged in any existing FOC-DFIM drive system.","PeriodicalId":185737,"journal":{"name":"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"A General Diagnostic Method for Doubly Fed Induction Machine Drives Based on Field Oriented Control\",\"authors\":\"D. Casadei, F. Filippetti, C. Rossi, A. Stefani, A. Capolino, A. Yazidi\",\"doi\":\"10.1109/DEMPED.2007.4393122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a diagnostic technique for the detection of incipient electrical faults in a doubly fed induction machine (DFIM) used for variable speed generation. In this application the stator windings are directly connected to the grid, whereas a converter, which controls the rotor currents by means of a field oriented control (FOC) scheme, supplies the rotor. The aim of this paper is to introduce a new diagnostic technique based on the analysis of the rotor inverter output voltages. In particular it will be shown that the frequency analysis of these signals leads to an effective diagnostic procedure. The presented system is suitable to be easily plugged in any existing FOC-DFIM drive system.\",\"PeriodicalId\":185737,\"journal\":{\"name\":\"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEMPED.2007.4393122\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEMPED.2007.4393122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本文提出了一种用于变速发电的双馈感应电机(DFIM)早期电气故障检测的诊断技术。在这种应用中,定子绕组直接连接到电网,而通过磁场定向控制(FOC)方案控制转子电流的转换器为转子供电。本文的目的是介绍一种基于转子逆变器输出电压分析的新型诊断技术。特别是,它将表明,这些信号的频率分析导致一个有效的诊断程序。所提出的系统适合于插入任何现有的foco - dfim驱动系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A General Diagnostic Method for Doubly Fed Induction Machine Drives Based on Field Oriented Control
This paper presents a diagnostic technique for the detection of incipient electrical faults in a doubly fed induction machine (DFIM) used for variable speed generation. In this application the stator windings are directly connected to the grid, whereas a converter, which controls the rotor currents by means of a field oriented control (FOC) scheme, supplies the rotor. The aim of this paper is to introduce a new diagnostic technique based on the analysis of the rotor inverter output voltages. In particular it will be shown that the frequency analysis of these signals leads to an effective diagnostic procedure. The presented system is suitable to be easily plugged in any existing FOC-DFIM drive system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信