L. Aslamova, N. Melenevska, N. Miroshnichenko, E. Grabovska, S. Miroshnichenko, D. Radko
{"title":"数字处理提高荧光图像对比度的可能性","authors":"L. Aslamova, N. Melenevska, N. Miroshnichenko, E. Grabovska, S. Miroshnichenko, D. Radko","doi":"10.1109/ELNANO.2013.6551995","DOIUrl":null,"url":null,"abstract":"The annual fluorography chest screening profoundly contributes to the total radiation dose delivered to the patient. The application of additional image contrast improving methods (high tube potential technique, anti-scatter grid method) increases the radiation dose to several times. X-ray image digital processing with special software is proposed as alternative method for visual contrast improvement to minimize the patient dose.","PeriodicalId":443634,"journal":{"name":"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The possibilities of the contrast improvement in fluorography image with digital processing\",\"authors\":\"L. Aslamova, N. Melenevska, N. Miroshnichenko, E. Grabovska, S. Miroshnichenko, D. Radko\",\"doi\":\"10.1109/ELNANO.2013.6551995\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The annual fluorography chest screening profoundly contributes to the total radiation dose delivered to the patient. The application of additional image contrast improving methods (high tube potential technique, anti-scatter grid method) increases the radiation dose to several times. X-ray image digital processing with special software is proposed as alternative method for visual contrast improvement to minimize the patient dose.\",\"PeriodicalId\":443634,\"journal\":{\"name\":\"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELNANO.2013.6551995\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE XXXIII International Scientific Conference Electronics and Nanotechnology (ELNANO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELNANO.2013.6551995","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The possibilities of the contrast improvement in fluorography image with digital processing
The annual fluorography chest screening profoundly contributes to the total radiation dose delivered to the patient. The application of additional image contrast improving methods (high tube potential technique, anti-scatter grid method) increases the radiation dose to several times. X-ray image digital processing with special software is proposed as alternative method for visual contrast improvement to minimize the patient dose.