{"title":"一种改进的多相感应电机断相故障检测方法","authors":"A. Javed, T. Izhar","doi":"10.1109/ICEE.2009.5173174","DOIUrl":null,"url":null,"abstract":"This paper presents an improved method for the detection of phase failure faults in poly phase Induction machines. Phase failure occurs when one of the three phases of the supply goes down during the running of motor. Poly phase induction motors continue to operate in this condition but under some severe operating conditions and eventually resulting in performance degradation and permanent burnouts. Detection of phase failure by voltage measurement is not useful in case of poly phase machines and it is not possible even by current monitoring if the machine is installed in a system with a mixture of 1-phase and three-phase loads. The proposed method relies on the continuous measurement the phase difference between the terminal voltages of the machine. Further it presents an improvement in other existing methods which are based on stator current monitoring. The proposed method has been simulated using MatLab/Simulink. The simulated results show the reliability and usefulness of the proposed method.","PeriodicalId":244218,"journal":{"name":"2009 Third International Conference on Electrical Engineering","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"An improved method for the detection of phase failure faults in poly phase Induction machines\",\"authors\":\"A. Javed, T. Izhar\",\"doi\":\"10.1109/ICEE.2009.5173174\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an improved method for the detection of phase failure faults in poly phase Induction machines. Phase failure occurs when one of the three phases of the supply goes down during the running of motor. Poly phase induction motors continue to operate in this condition but under some severe operating conditions and eventually resulting in performance degradation and permanent burnouts. Detection of phase failure by voltage measurement is not useful in case of poly phase machines and it is not possible even by current monitoring if the machine is installed in a system with a mixture of 1-phase and three-phase loads. The proposed method relies on the continuous measurement the phase difference between the terminal voltages of the machine. Further it presents an improvement in other existing methods which are based on stator current monitoring. The proposed method has been simulated using MatLab/Simulink. The simulated results show the reliability and usefulness of the proposed method.\",\"PeriodicalId\":244218,\"journal\":{\"name\":\"2009 Third International Conference on Electrical Engineering\",\"volume\":\"23 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-04-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Third International Conference on Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEE.2009.5173174\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Third International Conference on Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEE.2009.5173174","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文提出了一种改进的多相感应电机断相故障检测方法。在电动机运行过程中,当电源的三相中有一个出现故障时,就会发生相故障。多相感应电动机继续在这种条件下运行,但在一些严重的操作条件下,最终导致性能下降和永久烧坏。在多相电机中,通过电压测量来检测相位故障是没有用的,如果机器安装在一个单相和三相负载混合的系统中,甚至通过电流监测也不可能。该方法依赖于连续测量电机两端电压之间的相位差。进一步对现有的基于定子电流监测的方法进行了改进。采用MatLab/Simulink对该方法进行了仿真。仿真结果表明了该方法的可靠性和实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An improved method for the detection of phase failure faults in poly phase Induction machines
This paper presents an improved method for the detection of phase failure faults in poly phase Induction machines. Phase failure occurs when one of the three phases of the supply goes down during the running of motor. Poly phase induction motors continue to operate in this condition but under some severe operating conditions and eventually resulting in performance degradation and permanent burnouts. Detection of phase failure by voltage measurement is not useful in case of poly phase machines and it is not possible even by current monitoring if the machine is installed in a system with a mixture of 1-phase and three-phase loads. The proposed method relies on the continuous measurement the phase difference between the terminal voltages of the machine. Further it presents an improvement in other existing methods which are based on stator current monitoring. The proposed method has been simulated using MatLab/Simulink. The simulated results show the reliability and usefulness of the proposed method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信