一种基于配准的回波平面成像畸变校正软件

A. Gholipour, N. Kehtarnavaz, K. Gopinath, R. Briggs
{"title":"一种基于配准的回波平面成像畸变校正软件","authors":"A. Gholipour, N. Kehtarnavaz, K. Gopinath, R. Briggs","doi":"10.1109/EMBSW.2007.4454159","DOIUrl":null,"url":null,"abstract":"There exists a need for more accurate functional localization through the registration of functional to anatomical magnetic resonance brain images. This paper introduces a new software tool, named NPTK, that has been developed at the Signal and Image Processing Laboratory of the University of Texas at Dallas for improved functional localization in single- subject analysis. This software toolkit is developed based on recently introduced non-rigid registration and field map distortion correction techniques, which has been validated via in-vivo validation of retrospective distortion correction in Echo- Planar Imaging. The paper provides an overview of the entire functional localization pipeline, an algorithmic description of the developed software, and a discussion on the performance and applications of the software.","PeriodicalId":333843,"journal":{"name":"2007 IEEE Dallas Engineering in Medicine and Biology Workshop","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A Software Tool for Registration Based Distortion Correction in Echo Planar Imaging\",\"authors\":\"A. Gholipour, N. Kehtarnavaz, K. Gopinath, R. Briggs\",\"doi\":\"10.1109/EMBSW.2007.4454159\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There exists a need for more accurate functional localization through the registration of functional to anatomical magnetic resonance brain images. This paper introduces a new software tool, named NPTK, that has been developed at the Signal and Image Processing Laboratory of the University of Texas at Dallas for improved functional localization in single- subject analysis. This software toolkit is developed based on recently introduced non-rigid registration and field map distortion correction techniques, which has been validated via in-vivo validation of retrospective distortion correction in Echo- Planar Imaging. The paper provides an overview of the entire functional localization pipeline, an algorithmic description of the developed software, and a discussion on the performance and applications of the software.\",\"PeriodicalId\":333843,\"journal\":{\"name\":\"2007 IEEE Dallas Engineering in Medicine and Biology Workshop\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Dallas Engineering in Medicine and Biology Workshop\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMBSW.2007.4454159\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Dallas Engineering in Medicine and Biology Workshop","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMBSW.2007.4454159","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

通过功能与解剖磁共振脑图像的配准,需要更准确的功能定位。本文介绍了一种名为NPTK的新软件工具,它是由德克萨斯大学达拉斯分校的信号和图像处理实验室开发的,用于改进单主体分析中的功能定位。该软件工具包是基于最近引入的非刚性配准和场图畸变校正技术开发的,该技术已通过回声平面成像中回顾性畸变校正的体内验证进行了验证。本文概述了整个功能定位流程,对开发的软件进行了算法描述,并对软件的性能和应用进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Software Tool for Registration Based Distortion Correction in Echo Planar Imaging
There exists a need for more accurate functional localization through the registration of functional to anatomical magnetic resonance brain images. This paper introduces a new software tool, named NPTK, that has been developed at the Signal and Image Processing Laboratory of the University of Texas at Dallas for improved functional localization in single- subject analysis. This software toolkit is developed based on recently introduced non-rigid registration and field map distortion correction techniques, which has been validated via in-vivo validation of retrospective distortion correction in Echo- Planar Imaging. The paper provides an overview of the entire functional localization pipeline, an algorithmic description of the developed software, and a discussion on the performance and applications of the software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信