{"title":"非均匀辐照度对光伏组件电气特性的影响","authors":"M. A. Hasan, S. Parida","doi":"10.1109/IICPE.2014.7115786","DOIUrl":null,"url":null,"abstract":"This paper presents the study of effect of non-uniform irradiance on electrical characteristics of an assembly of solar PV panel. Study is based on a one diode model of PV panel. Effect is simulated in MATLAB-Simulink environment. In a solar power plant series Parallel connections of PV panels are used for obtaining desired voltage and current level. Under mismatch or non-uniform irradiance condition a hot spot formation may damage the PV panel. A bypass diode is provided with PV panel to avoid hot spot formation. Under non-uniform irradiance condition, due to presence of bypass diode, I-V and P-V characteristics are quite different from that of uniform irradiance condition. Results obtained show the presence of multiple peaks in P-V characteristics under non-uniform irradiance. This establishes requirement of a non-conventional maximum power point tracker algorithm.","PeriodicalId":206767,"journal":{"name":"2014 IEEE 6th India International Conference on Power Electronics (IICPE)","volume":"1959 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Effect of non-uniform irradiance on electrical characteristics of an assembly of PV panels\",\"authors\":\"M. A. Hasan, S. Parida\",\"doi\":\"10.1109/IICPE.2014.7115786\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the study of effect of non-uniform irradiance on electrical characteristics of an assembly of solar PV panel. Study is based on a one diode model of PV panel. Effect is simulated in MATLAB-Simulink environment. In a solar power plant series Parallel connections of PV panels are used for obtaining desired voltage and current level. Under mismatch or non-uniform irradiance condition a hot spot formation may damage the PV panel. A bypass diode is provided with PV panel to avoid hot spot formation. Under non-uniform irradiance condition, due to presence of bypass diode, I-V and P-V characteristics are quite different from that of uniform irradiance condition. Results obtained show the presence of multiple peaks in P-V characteristics under non-uniform irradiance. This establishes requirement of a non-conventional maximum power point tracker algorithm.\",\"PeriodicalId\":206767,\"journal\":{\"name\":\"2014 IEEE 6th India International Conference on Power Electronics (IICPE)\",\"volume\":\"1959 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE 6th India International Conference on Power Electronics (IICPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IICPE.2014.7115786\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE 6th India International Conference on Power Electronics (IICPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IICPE.2014.7115786","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of non-uniform irradiance on electrical characteristics of an assembly of PV panels
This paper presents the study of effect of non-uniform irradiance on electrical characteristics of an assembly of solar PV panel. Study is based on a one diode model of PV panel. Effect is simulated in MATLAB-Simulink environment. In a solar power plant series Parallel connections of PV panels are used for obtaining desired voltage and current level. Under mismatch or non-uniform irradiance condition a hot spot formation may damage the PV panel. A bypass diode is provided with PV panel to avoid hot spot formation. Under non-uniform irradiance condition, due to presence of bypass diode, I-V and P-V characteristics are quite different from that of uniform irradiance condition. Results obtained show the presence of multiple peaks in P-V characteristics under non-uniform irradiance. This establishes requirement of a non-conventional maximum power point tracker algorithm.