Tamanrasset的无阻塞定日镜场布局

Dhikra Derbal, A. Abderrezak, Seif Eddine Chehaidia
{"title":"Tamanrasset的无阻塞定日镜场布局","authors":"Dhikra Derbal, A. Abderrezak, Seif Eddine Chehaidia","doi":"10.1109/IRASET52964.2022.9737773","DOIUrl":null,"url":null,"abstract":"The present paper represents a case study of Tamanrasset city in terms of direct normal irradiance and wind speed, as well as an arrangement of 23 heliostats in a symmetrical field oriented to the North. A mathematical model of a graphical method for no-blocking heliostat field layout was followed to create an algorithm executed on MATLAB software in order to obtain the optimal positions of heliostats. The optical performance of the field was obtained by exploiting the heliostats' positions and the meteorological data of the chosen region based on Solar Pilot. The results show that the overall optical efficiency of the field is about 79% with a power output of 2066.5 (kW), as well as there is no blockage of heliostats.","PeriodicalId":377115,"journal":{"name":"2022 2nd International Conference on Innovative Research in Applied Science, Engineering and Technology (IRASET)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"No-blocking Heliostat Field Layout in Tamanrasset\",\"authors\":\"Dhikra Derbal, A. Abderrezak, Seif Eddine Chehaidia\",\"doi\":\"10.1109/IRASET52964.2022.9737773\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present paper represents a case study of Tamanrasset city in terms of direct normal irradiance and wind speed, as well as an arrangement of 23 heliostats in a symmetrical field oriented to the North. A mathematical model of a graphical method for no-blocking heliostat field layout was followed to create an algorithm executed on MATLAB software in order to obtain the optimal positions of heliostats. The optical performance of the field was obtained by exploiting the heliostats' positions and the meteorological data of the chosen region based on Solar Pilot. The results show that the overall optical efficiency of the field is about 79% with a power output of 2066.5 (kW), as well as there is no blockage of heliostats.\",\"PeriodicalId\":377115,\"journal\":{\"name\":\"2022 2nd International Conference on Innovative Research in Applied Science, Engineering and Technology (IRASET)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 2nd International Conference on Innovative Research in Applied Science, Engineering and Technology (IRASET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IRASET52964.2022.9737773\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 2nd International Conference on Innovative Research in Applied Science, Engineering and Technology (IRASET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRASET52964.2022.9737773","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文以塔曼拉塞特市为例,从直接正常辐照度和风速的角度进行了研究,并在一个面向北方的对称场中布置了23个定日镜。根据无遮挡定日镜视场布局图形化方法的数学模型,建立了在MATLAB软件上执行的定日镜最佳位置求解算法。利用定日镜的位置和选定区域的气象数据,获得了该区域的光学性能。结果表明,该光场的总光效率约为79%,输出功率为2066.5 (kW),且无定日镜遮挡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
No-blocking Heliostat Field Layout in Tamanrasset
The present paper represents a case study of Tamanrasset city in terms of direct normal irradiance and wind speed, as well as an arrangement of 23 heliostats in a symmetrical field oriented to the North. A mathematical model of a graphical method for no-blocking heliostat field layout was followed to create an algorithm executed on MATLAB software in order to obtain the optimal positions of heliostats. The optical performance of the field was obtained by exploiting the heliostats' positions and the meteorological data of the chosen region based on Solar Pilot. The results show that the overall optical efficiency of the field is about 79% with a power output of 2066.5 (kW), as well as there is no blockage of heliostats.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信