{"title":"改进的下垂控制与直流电网共振阻尼能力","authors":"A. Egea-Àlvarez, S. Fekriasl, E. Prieto‐Araujo","doi":"10.1049/CP.2019.0015","DOIUrl":null,"url":null,"abstract":"The concept of the so-called droop control has been widely discussed in the literature as the preferred controller for Voltage Source Converter for High Voltage Direct Current (VSC-HVDC) multiterminal and DC grid schemes. Droop control provides fast dynamic response and power-sharing between converter stations among other advantages but, as the controller is usually implemented as a merely proportional gain, the DC grid resonances damping is often very poor. This is because although the grids under study are DC, a broad range of high-frequency components and transient dynamics are inevitable in DC grids caused by long cables and switching to name a few. Conventional droops based on proportional gain are not able to handle such frequency-dependant issues of the DC grids. To improve the DC dynamic response, this paper presents a new droop controller where a DC resonance mitigation compensator is augmented to the conventional droop control that will result in an improved droop compensation by guaranteeing that power-sharing task will satisfactorily meet the desired damping requirements.","PeriodicalId":362400,"journal":{"name":"15th IET International Conference on AC and DC Power Transmission (ACDC 2019)","volume":"93 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improved droop control with DC grid resonance damping capability\",\"authors\":\"A. Egea-Àlvarez, S. Fekriasl, E. Prieto‐Araujo\",\"doi\":\"10.1049/CP.2019.0015\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The concept of the so-called droop control has been widely discussed in the literature as the preferred controller for Voltage Source Converter for High Voltage Direct Current (VSC-HVDC) multiterminal and DC grid schemes. Droop control provides fast dynamic response and power-sharing between converter stations among other advantages but, as the controller is usually implemented as a merely proportional gain, the DC grid resonances damping is often very poor. This is because although the grids under study are DC, a broad range of high-frequency components and transient dynamics are inevitable in DC grids caused by long cables and switching to name a few. Conventional droops based on proportional gain are not able to handle such frequency-dependant issues of the DC grids. To improve the DC dynamic response, this paper presents a new droop controller where a DC resonance mitigation compensator is augmented to the conventional droop control that will result in an improved droop compensation by guaranteeing that power-sharing task will satisfactorily meet the desired damping requirements.\",\"PeriodicalId\":362400,\"journal\":{\"name\":\"15th IET International Conference on AC and DC Power Transmission (ACDC 2019)\",\"volume\":\"93 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"15th IET International Conference on AC and DC Power Transmission (ACDC 2019)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1049/CP.2019.0015\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"15th IET International Conference on AC and DC Power Transmission (ACDC 2019)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/CP.2019.0015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Improved droop control with DC grid resonance damping capability
The concept of the so-called droop control has been widely discussed in the literature as the preferred controller for Voltage Source Converter for High Voltage Direct Current (VSC-HVDC) multiterminal and DC grid schemes. Droop control provides fast dynamic response and power-sharing between converter stations among other advantages but, as the controller is usually implemented as a merely proportional gain, the DC grid resonances damping is often very poor. This is because although the grids under study are DC, a broad range of high-frequency components and transient dynamics are inevitable in DC grids caused by long cables and switching to name a few. Conventional droops based on proportional gain are not able to handle such frequency-dependant issues of the DC grids. To improve the DC dynamic response, this paper presents a new droop controller where a DC resonance mitigation compensator is augmented to the conventional droop control that will result in an improved droop compensation by guaranteeing that power-sharing task will satisfactorily meet the desired damping requirements.