Sarim Ahmed Qamar, Amir Sohail, K. Qureshi, Ajmal Shah, N. Irfan
{"title":"采用CFX的不同孔数文丘里洗涤器的粉尘收集效率","authors":"Sarim Ahmed Qamar, Amir Sohail, K. Qureshi, Ajmal Shah, N. Irfan","doi":"10.1109/ICET.2016.7813269","DOIUrl":null,"url":null,"abstract":"In the present study, computational fluid dynamics (CFD) investigation of dust particle collection efficiency in a force feed venturi scrubber has been performed using ANSYS CFX. A Venturi scrubber provides an effective way to remove dust particles flowing in a contaminated gas which are captured in fine droplets formed due to disintegration of a liquid as a result of high kinetic energy of air. Eulerian-Lagrangian approach is used to analyze the dust particle collection in a venturi scrubber for gas (air) flow rate at 1 g/s and liquid flow rate of 6 g/s with 2, 4, 6 and 8 orifices placed at the start of throat, end of throat and on the converging section. Cascade atomization and breakup model (CAB) is used for the prediction of liquid breakup in the venturi scrubber. Dust particles (TiO2) having diameter of 1 μm are used in this research. Velocity of gas at the throat, droplet size, volume fractions and collection efficiency are studied to analyze the working of venturi scrubber.","PeriodicalId":285090,"journal":{"name":"2016 International Conference on Emerging Technologies (ICET)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Dust particle collection efficiency of venturi scrubber with varying number of orifices using CFX\",\"authors\":\"Sarim Ahmed Qamar, Amir Sohail, K. Qureshi, Ajmal Shah, N. Irfan\",\"doi\":\"10.1109/ICET.2016.7813269\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present study, computational fluid dynamics (CFD) investigation of dust particle collection efficiency in a force feed venturi scrubber has been performed using ANSYS CFX. A Venturi scrubber provides an effective way to remove dust particles flowing in a contaminated gas which are captured in fine droplets formed due to disintegration of a liquid as a result of high kinetic energy of air. Eulerian-Lagrangian approach is used to analyze the dust particle collection in a venturi scrubber for gas (air) flow rate at 1 g/s and liquid flow rate of 6 g/s with 2, 4, 6 and 8 orifices placed at the start of throat, end of throat and on the converging section. Cascade atomization and breakup model (CAB) is used for the prediction of liquid breakup in the venturi scrubber. Dust particles (TiO2) having diameter of 1 μm are used in this research. Velocity of gas at the throat, droplet size, volume fractions and collection efficiency are studied to analyze the working of venturi scrubber.\",\"PeriodicalId\":285090,\"journal\":{\"name\":\"2016 International Conference on Emerging Technologies (ICET)\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Conference on Emerging Technologies (ICET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICET.2016.7813269\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Emerging Technologies (ICET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICET.2016.7813269","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Dust particle collection efficiency of venturi scrubber with varying number of orifices using CFX
In the present study, computational fluid dynamics (CFD) investigation of dust particle collection efficiency in a force feed venturi scrubber has been performed using ANSYS CFX. A Venturi scrubber provides an effective way to remove dust particles flowing in a contaminated gas which are captured in fine droplets formed due to disintegration of a liquid as a result of high kinetic energy of air. Eulerian-Lagrangian approach is used to analyze the dust particle collection in a venturi scrubber for gas (air) flow rate at 1 g/s and liquid flow rate of 6 g/s with 2, 4, 6 and 8 orifices placed at the start of throat, end of throat and on the converging section. Cascade atomization and breakup model (CAB) is used for the prediction of liquid breakup in the venturi scrubber. Dust particles (TiO2) having diameter of 1 μm are used in this research. Velocity of gas at the throat, droplet size, volume fractions and collection efficiency are studied to analyze the working of venturi scrubber.