三相感应发电机单相运行时的电能质量

Vikash Kumar
{"title":"三相感应发电机单相运行时的电能质量","authors":"Vikash Kumar","doi":"10.1109/PARC52418.2022.9726572","DOIUrl":null,"url":null,"abstract":"The creation and evaluation of a STATCOM to achieve current and voltage balancing in an induction generator with three phases in a single-phase operation feeding a single-phase diode rectifier load are presented in this study. Simulink is used to represent the overall system, and the overall system’s performance is investigated. Models of a single-phase three-phase induction generator are used to feed an experimental setup that includes a three-phase induction generator in this study. The wind turbine induction generator is connected to the grid via a 25-kilometer cable (WTIG). A 125 kV/25 kV transformer integrates a 120 kV, 60 Hz regional grid. Using a STATCOM-based voltage regulator, the final results show that terminal voltage can be kept constant for both nonlinear balanced and unbalanced loads with no harmonics.","PeriodicalId":158896,"journal":{"name":"2022 2nd International Conference on Power Electronics & IoT Applications in Renewable Energy and its Control (PARC)","volume":"4646 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Aspects of Three Phase Induction Generator in Single-Phase Operation in terms of Power Quality\",\"authors\":\"Vikash Kumar\",\"doi\":\"10.1109/PARC52418.2022.9726572\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The creation and evaluation of a STATCOM to achieve current and voltage balancing in an induction generator with three phases in a single-phase operation feeding a single-phase diode rectifier load are presented in this study. Simulink is used to represent the overall system, and the overall system’s performance is investigated. Models of a single-phase three-phase induction generator are used to feed an experimental setup that includes a three-phase induction generator in this study. The wind turbine induction generator is connected to the grid via a 25-kilometer cable (WTIG). A 125 kV/25 kV transformer integrates a 120 kV, 60 Hz regional grid. Using a STATCOM-based voltage regulator, the final results show that terminal voltage can be kept constant for both nonlinear balanced and unbalanced loads with no harmonics.\",\"PeriodicalId\":158896,\"journal\":{\"name\":\"2022 2nd International Conference on Power Electronics & IoT Applications in Renewable Energy and its Control (PARC)\",\"volume\":\"4646 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 2nd International Conference on Power Electronics & IoT Applications in Renewable Energy and its Control (PARC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PARC52418.2022.9726572\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 2nd International Conference on Power Electronics & IoT Applications in Renewable Energy and its Control (PARC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PARC52418.2022.9726572","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了三相感应发电机在单相工作中为单相二极管整流负载供电时实现电流和电压平衡的STATCOM的创建和评估。采用Simulink来表示整个系统,并对整个系统的性能进行了研究。在本研究中,采用单相三相感应发电机的模型来馈送一个包含三相感应发电机的实验装置。风力涡轮感应发电机通过25公里长的电缆(WTIG)连接到电网。一个125千伏/25千伏变压器集成了一个120千伏、60赫兹的区域电网。采用基于statcom的电压调节器,最终结果表明,无论对非线性平衡负载还是不平衡负载,终端电压都可以保持恒定,且无谐波。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Aspects of Three Phase Induction Generator in Single-Phase Operation in terms of Power Quality
The creation and evaluation of a STATCOM to achieve current and voltage balancing in an induction generator with three phases in a single-phase operation feeding a single-phase diode rectifier load are presented in this study. Simulink is used to represent the overall system, and the overall system’s performance is investigated. Models of a single-phase three-phase induction generator are used to feed an experimental setup that includes a three-phase induction generator in this study. The wind turbine induction generator is connected to the grid via a 25-kilometer cable (WTIG). A 125 kV/25 kV transformer integrates a 120 kV, 60 Hz regional grid. Using a STATCOM-based voltage regulator, the final results show that terminal voltage can be kept constant for both nonlinear balanced and unbalanced loads with no harmonics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信