J. Hwang, H.-S. Park, D. Shim, K. Na, Wonseo Choi, S. Choi
{"title":"采用双轴微磁通门传感元件的电子罗盘","authors":"J. Hwang, H.-S. Park, D. Shim, K. Na, Wonseo Choi, S. Choi","doi":"10.1109/SENSOR.2003.1217091","DOIUrl":null,"url":null,"abstract":"This paper presents a micro fluxgate sensor fabricated by Si-based Micro Electro Mechanical Systems (MEMS). To measure X- and Y-axis magnetic fields, two fluxgate sensing elements were perpendicularly aligned. The fluxgate sensor was composed of rectangular-ring shaped magnetic core, solenoid excitation and pick-up coils. The 2 /spl mu/m thick Ni/sub 0.8/Fe/sub 0.2/ (permalloy) magnetic core layer was electroplated with photoresist frame using sputtered Ni/sub 0.8/Fe/sub 0.2/ seed layer. The fabricated fluxgate chip size was 4.5/spl times/2.7 mm/sup 2/. Excellent linear response over the range of -100 /spl mu/T to +100 /spl mu/T was obtained with 210 V/T sensitivity at excitation square wave of 2.8 V/sub p-p/ and 1.2 MHz. When two-axis fluxgate sensing element was rotated in terrestrial field, induced second harmonic voltages from X-and Y-axis were sine and cosine wave without distortion, respectively. It is very useful to commercialize the portable navigation system including north-up and map matching, military research, medical research, and space research.","PeriodicalId":196104,"journal":{"name":"TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664)","volume":"93 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Electronic compass using two-axis micro fluxgate sensing element\",\"authors\":\"J. Hwang, H.-S. Park, D. Shim, K. Na, Wonseo Choi, S. Choi\",\"doi\":\"10.1109/SENSOR.2003.1217091\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a micro fluxgate sensor fabricated by Si-based Micro Electro Mechanical Systems (MEMS). To measure X- and Y-axis magnetic fields, two fluxgate sensing elements were perpendicularly aligned. The fluxgate sensor was composed of rectangular-ring shaped magnetic core, solenoid excitation and pick-up coils. The 2 /spl mu/m thick Ni/sub 0.8/Fe/sub 0.2/ (permalloy) magnetic core layer was electroplated with photoresist frame using sputtered Ni/sub 0.8/Fe/sub 0.2/ seed layer. The fabricated fluxgate chip size was 4.5/spl times/2.7 mm/sup 2/. Excellent linear response over the range of -100 /spl mu/T to +100 /spl mu/T was obtained with 210 V/T sensitivity at excitation square wave of 2.8 V/sub p-p/ and 1.2 MHz. When two-axis fluxgate sensing element was rotated in terrestrial field, induced second harmonic voltages from X-and Y-axis were sine and cosine wave without distortion, respectively. It is very useful to commercialize the portable navigation system including north-up and map matching, military research, medical research, and space research.\",\"PeriodicalId\":196104,\"journal\":{\"name\":\"TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664)\",\"volume\":\"93 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2003.1217091\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2003.1217091","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Electronic compass using two-axis micro fluxgate sensing element
This paper presents a micro fluxgate sensor fabricated by Si-based Micro Electro Mechanical Systems (MEMS). To measure X- and Y-axis magnetic fields, two fluxgate sensing elements were perpendicularly aligned. The fluxgate sensor was composed of rectangular-ring shaped magnetic core, solenoid excitation and pick-up coils. The 2 /spl mu/m thick Ni/sub 0.8/Fe/sub 0.2/ (permalloy) magnetic core layer was electroplated with photoresist frame using sputtered Ni/sub 0.8/Fe/sub 0.2/ seed layer. The fabricated fluxgate chip size was 4.5/spl times/2.7 mm/sup 2/. Excellent linear response over the range of -100 /spl mu/T to +100 /spl mu/T was obtained with 210 V/T sensitivity at excitation square wave of 2.8 V/sub p-p/ and 1.2 MHz. When two-axis fluxgate sensing element was rotated in terrestrial field, induced second harmonic voltages from X-and Y-axis were sine and cosine wave without distortion, respectively. It is very useful to commercialize the portable navigation system including north-up and map matching, military research, medical research, and space research.